21-30 of 71
|
What is the Difference Between P-Command and Stepper when Using National Instruments Motion Products? I have heard that Position Command (P-Command) is similar to stepper control and I want to know what the difference is between the two. So, what is the difference between P-Command and Stepper when using National Instruments Motion Products? URL: http://digital.ni.com/public.nsf/allkb/7D26773D145497428625723E0009B0A0
Digital Output on Motion Controller Not Functioning I have a PCI-7350 and am trying to output signals on the DIO lines in Measurement and Automation Explorer (MAX) and using Set I/O Port MOMO.flx. I can read the inputs on the first port, but line 5 on the second port never has any output and I never see any output on the third port. Why do my URL: http://digital.ni.com/public.nsf/allkb/6363F79BE8031EF38625722D007D5E65
Motion 컨트롤러의 디지털 출력이 동작하지 않습니다. PCI-7350를 가지고 있고 MAX(Measurement and Automation Explorer)에서 DIO 라인들에서 신호를 출력하려고 하고 Set I/O Port MOMO.flx를 사용하려고 합니다. 첫번째 포트에서는 입력들을 읽을수 있습니다. 그러나, 두번째 포트의 라인 5 에서는 어떤 출력도 나오지 않고, 세번째 포■> URL: http://digital.ni.com/public.nsf/allkb/B78A4910D6362260862572360008CD27
设置运动控制器的模数转换(ADC)范围 我使用Read ADC VI来读取运动控制器上的一个模拟电压。使用Set ADC Range VI来更改电压的范围,但是在我读出来的数值没有变化。为什么Set ADC Range VI不工作也没有返回错误? URL: http://digital.ni.com/public.nsf/allkb/41C73541908FC81B4825721900239EC9
Changing Motion Controller Settings on Default 73xx Settings Page in MAX I am using a PCI or PXI NI Motion device, and I have selected and saved settings for each individual axis in MAX. When I go to the page titled 'Default 73xx Settings' and make any selections, it immediately erases all of my previous settings. Is this expected behavior? URL: http://digital.ni.com/public.nsf/allkb/0C34A033AAC0EA7C8625721700741D36
MAX에서 디폴트로된 73xx 설정페이지에서 Motion 컨트롤러 설정변경 PCI 또는 PXI NI Motion 장비를 사용하고 있고, MAX에서 각각의 축에 대해서 설정을 선택하고 저장하였습니다. 'Default 73xx Settings' 이라는 제목의 페이지로 가서 어떤 선택을 하게되면 제가 이미 해놓았던 모든 설정들이 즉시 지워지게 됩니다. 이런 동작이 정상적인 것입■> URL: http://digital.ni.com/public.nsf/allkb/17E2FF682F38C2FC862572360007E099
在MAX的默认73XX设置页中改变运动控制卡的设置 我在使用一块NI的PCI 或 PXI 运动控制设备, 我已经在MAX中为每个轴选择和保存了设置.当我进入名为 "Default 73xx Settings" 的页面,进行设置时,它立即删除了我之前进行的所有配置. 应该是这样吗? URL: http://digital.ni.com/public.nsf/allkb/ACE504ADDD02E52D862574000018A081
Using a Non-7390 Motion Controller with a P-Command Drive I have my 7330/7340/7350 motion controller configured in MAX in closed loop stepper mode and it is connected to a p-command drive. Every time I do a move, the encoder feedback always shows that the motor is a few counts off. URL: http://digital.ni.com/public.nsf/allkb/3003271B3C6095438625720B0081BDFE
使用非7390系列的運動控制器來搭配P-Command馬達驅動器 我有7330/7340/7350系列的運動控制器,在MAX下設定成閉迴路步進模式(closed loop stepper mode),然後連接至p-command的馬達驅動器。每次我完成一個運動,編碼器的回饋顯示馬達偏離我所設定的目標位置。 URL: http://digital.ni.com/public.nsf/allkb/BA90C6433A131D0D8625739F001B1EDC
在P-command Drive上使用非7390的运动控制卡 我的7330/7340/7350运动控制卡,在MAX中配置闭环步进模式,它连接到了一个P-Command驱动器。每次运动时,编码器反馈都会显示电机偏离了一点位置 URL: http://digital.ni.com/public.nsf/allkb/44AAD965CC678E778625740000186901
Sort by: