Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
KnowledgeBase

Category(s) Selected [start over]

Software
: Driver Software [remove] ,
Hardware
: CompactRIO [remove] ,
1-10 of 47
KnowledgeBase [see results below]. To refine your results, select another category.
Software
NI-CAN (2)
NI-DAQmx (12)
NI-DAQmx Base (2)
NI-FieldPoint (5)
NI-RIO (28)
NI-VISA (1)
Hardware
Chassis (Backplanes) (7)
Controllers (21)
Analog Input Modules (13)
Analog Output Modules (1)
Digital Input Modules (3)
Digital Output Modules (5)
Question Type
Bug Fix/ Error Message/ Error Code (9)
FAQ (7)
Install/Config (9)
Programming (8)
Specifications/ Documentation (1)
Unexpected Behavior/ Bad Reading (13)
Document Languages
English (24)
Spanish (1)
Japanese (3)
Chinese (Simplified) (11)
Chinese (Traditional) (5)
Korean (3)

Sort by:
1-10 of 47
Error -63001 NI-RIO FPGA Communications Occurs With DMA Transfers From Host to FPGA I am trying to do a DMA transfer from the 900x cRIO RT controller to the cRIO FPGA. The FPGA code compiles. However, when I run the code I get a Real-Time error saying the following: Error -63001: NI-RIO FPGA Communications.Framework: (Hex URL: http://digital.ni.com/public.nsf/allkb/257AF49E2110630F8625741F0062D292
Error 50150 - Reboot USB 9162 after upgrading to DAQmx 8.7 Immediately following an upgrade to DAQmx 8.7 and using a USB-9162, a user may see error 50150 when attempting to use the device until they restart Measurement and Automation Explorer (MAX) or reboot. The Found New Hardware Wizard may also prompt you to reboot. USB-9162 devices should not URL: http://digital.ni.com/public.nsf/allkb/D046874B01378D42862574170072561E
How Do I Acquire Data from More than One CompactDAQ Module in LabVIEW SignalExpress? I need to acquire data from multiple modules in my cDAQ-9172 chassis using LabVIEW SignalExpress. How do I do accomplish this? URL: http://digital.ni.com/public.nsf/allkb/7F890A8413C0544A862573F4006D4E63
Can I use FPGA Emulation Mode in a PXI System with a R Series Expansion Chassis for cRIO? I have a cRIO Expansion Chassis NI-9151 connected to an R-Series PXI-7833R card. I am trying to use the "Use Target Hardware for I/O" option to emulate I/O of the modules on the cRIO expansion chassis, but instead of the actual signals, I seem to be getting random data back. Isn't this URL: http://digital.ni.com/public.nsf/allkb/76240748163E2D33862573EF003ADB98
Moving CompactRIO VIs with Uncalibrated Data to FPGA Targets with Calibrated Data In versions of NI-RIO prior to 2.4, C Series Modules only return binary (uncalibrated) data, which requires the host VI to apply calibration coefficients and convert the data to engineering units in software. After installing NI-RIO 2.4 or later, the default behavior for AI/AO modules is to URL: http://digital.ni.com/public.nsf/allkb/254BBC14267D2972862573E000824912
为什么我的USB数据采集模块出现“Unable to Loacate a Driver”错误? 我刚刚购买了一个USB数据采集模块(9211或9215),并在Windows系统的计算机上安装了NI-DAQmx。当我插入我的USB模块时,我得到一个错误:“Windows was unable to locate a driver for this device.”该如何出来? URL: http://digital.ni.com/public.nsf/allkb/01F862902AA81CE6482573A200098B96
NI 9237真实的激励电压与指定电压值不同 在用NI 9237创建Strain或者Custom Voltage with Excitation的DAQmx任务时,在任务中指定的激励电压与我在Ex+和Ex-两端之间测到的电压不一致。例如,在创建任务时,我指定的激励电压为6V。然而,我在Ex+和Ex URL: http://digital.ni.com/public.nsf/allkb/3F7E5F74EE6458AB4825736F00208909
Channel Names Cause Incorrect Analog Output on NI USB DAQ Devices When generating a voltage on the analog output of my USB devices (such as the USB-6008/9, cDAQ 9263) I notice that if the channels in my task have a numeric value at the end of the channel name, then I generate incorrect values. Why is this and how can I fix it? URL: http://digital.ni.com/public.nsf/allkb/061D00FB903F2F6586257361006C5505
Unexpected Delay When Using DAQmx Analog Start Trigger When I use a DAQmx analog edge start trigger with an M Series DAQ device, my program appears to last 250-300ms longer than when I do not use an analog edge start trigger. Why is this happening, and is there anything that I can do to get around it? URL: http://digital.ni.com/public.nsf/allkb/AF8AA09A3323B0B38625734F00496E02
Why do I see Spurious Returns when using multiple Wait on IRQ Nodes on VxWorks Real Time Targets? NI-RIO 2.3 with LabVIEW 8.5 supports multiple Wait on IRQ nodes in a single VI, however, I see spurious returns from the "Wait on IRQ" Method Node when using cRIO-901x Controllers. This does not occur on my cRIO-900x Controllers or any other Pharlap based Real-Time controller. Why does this URL: http://digital.ni.com/public.nsf/allkb/A868BA261986A486482573380077794D