Cart
|
Help
NI Home
>
Support
> KnowledgeBase
KnowledgeBase
Select your country
Category(s) Selected
[
start over
]
Software
: Driver Software [
remove
] ,
Hardware
: Multifunction DAQ (MIO) [
remove
] ,
31-40 of
280
KnowledgeBase [
see results below
]. To refine your results, select another category.
Software
NI ELVIS Driver VIs
(15)
NI-CAN
(2)
NI-DAQ
(119)
NI-DAQmx
(139)
NI-DAQmx Base
(45)
NI-DSA
(1)
NI-Device
(3)
NI-RIO
(1)
Hardware
Basic
(8)
Connector Blocks
(18)
E Series
(79)
Ethernet DAQ
(1)
M Series
(40)
Portable
(53)
Real-Time
(1)
S Series
(28)
SC Series
(1)
Wireless DAQ
(7)
Question Type
Bug Fix/ Error Message/ Error Code
(44)
FAQ
(45)
Install/Config
(32)
Programming
(83)
Specifications/ Documentation
(47)
Unexpected Behavior/ Bad Reading
(29)
Document Languages
English
(165)
Spanish
(10)
French
(2)
Japanese
(44)
Chinese (Simplified)
(19)
Chinese (Traditional)
(12)
Korean
(28)
Search KnowledgeBase Documents:
Sort by:
Date (Most recent)
Title (A-Z)
31-40 of
280
Previous
|
Next
Why Does My Real-Time Controller with NI-RIO and NI-Sync Crash?
I have a real-time controller with NI-RIO 2.3 and NI-Sync 2.0.1 installed and the controller will not boot. Why does my controller crash when booting?
URL:
http://digital.ni.com/public.nsf/allkb/FECB7E15D5025002862573630012F384
Unexpected Delay When Using DAQmx Analog Start Trigger
When I use a DAQmx analog edge start trigger with an M Series DAQ device, my program appears to last 250-300ms longer than when I do not use an analog edge start trigger. Why is this happening, and is there anything that I can do to get around it?
URL:
http://digital.ni.com/public.nsf/allkb/AF8AA09A3323B0B38625734F00496E02
使用DAQmx模拟触发的意外延迟
当我使用M系列DAQ设备的模拟边沿开始触发(DAQmx驱动)时,程序运行比不使用触发要长250-300毫秒。为什么会有这样的现象,是否有什么方法可以解决这个问题?
URL:
http://digital.ni.com/public.nsf/allkb/5A341AF57090C4E6862574A0003F2D5A
Internally Routing Counter Signals in LabVIEW
I want to route the output signal of one counter to the source/gate of another counter on the same card or to a specific PFI line. Can I do this without externally connecting the two pins?
URL:
http://digital.ni.com/public.nsf/allkb/8A85E97855EDADC98625730C00065F58
怎么才能够在LabVIEW下路由计数器的输出
我想要将一个计数器的输出路由至同一块板卡上的另一个计数器的source/gate端或者到一个特定的PFI引脚上。我能否不通过外部连接着两个引脚而实现这样的功能?
URL:
http://digital.ni.com/public.nsf/allkb/C49A281133F4D39F862573C900442CDE
Do I Need to Manually Set the Range on my DAQ Device When Using TEDS Sensors?
When using a TEDS device with either a real TEDS sensor a virtual TEDS file, do I need to set the range of the DAQ input task to optimize my resolution?
URL:
http://digital.ni.com/public.nsf/allkb/F902F12F97D0F9F7862573000081B9BC
DAQの同期プログラムでエラー-89140などが発生してしまいますが、どうすれば回避できるのでしょうか?
PXIシステムを使用しています。DAQの同期を行うプログラムを実行しようとすると、エラー-89140などの、経路関連のエラーが発生してしまいます。過去には問題なく実行できていました。どうすれば回避できるのでしょうか?
URL:
http://digital.ni.com/public.nsf/allkb/F4987B403CC3A56C862572EF00297CC6
Why do I get DAQmx Error 50412 for Finite or Continuous Acquisition with my PCI-MIO-16XE-50 Board?
I am attempting to test my PCI-MIO-16XE-50 in Measurement and Automation Explorer (MAX) but I keep getting DAQmx Error 50412. I only get this error under Continuous Samples or N Samples acquisition, and not during 1 Sample (On Demand) or 1 Sample (HW Timed). I also see this
URL:
http://digital.ni.com/public.nsf/allkb/6D87B7A202301AC4862572ED00103FDC
Error -200474 With Digital Frequency Example VIs Modified for Continuous Acquisition
I modified the Meas Dig Frequency-Low Freq 1 Ctr example VI to acquire continuously, and unless there is a signal with a frequency greater than 100Hz, I get Error -200474. What is wrong and how can I fix it?
URL:
http://digital.ni.com/public.nsf/allkb/4E017925BDF2DC2D862572E6007C9594
執行持續頻率量測相關 VI 時出現 Error -200474
我修改了 Meas Dig Frequency-Low Freq 1 Ctr 的範例程式來進行持續擷取,但除非數入端有大於100Hz的訊號存在,我會得到 Error -200474,到底發生什麼事?該如何修復呢?
URL:
http://digital.ni.com/public.nsf/allkb/BEB4A39A6883D6B68625752B0012475C