Cart
|
Help
NI Home
>
Support
> KnowledgeBase
KnowledgeBase
Select your country
Category(s) Selected
[
start over
]
Software
: Driver Software [
remove
] ,
Hardware
: Counter/Timers (TIO) [
remove
] ,
1-10 of
19
KnowledgeBase [
see results below
]. To refine your results, select another category.
Software
NI-DAQ
(10)
NI-DAQmx
(9)
Question Type
Bug Fix/ Error Message/ Error Code
(4)
FAQ
(4)
Programming
(6)
Specifications/ Documentation
(4)
Unexpected Behavior/ Bad Reading
(1)
Document Languages
English
(9)
French
(1)
Japanese
(6)
Chinese (Simplified)
(2)
Korean
(1)
Search KnowledgeBase Documents:
Sort by:
Date (Most recent)
Title (A-Z)
1-10 of
19
Next
Using One Counter to Generate a Retriggerable Finite Digital Pulse Train with a PCI-6602 and DAQmx
Is it possible to create a finite digital pulse train using only one counter on my PCI-6602 using DAQmx?
URL:
http://digital.ni.com/public.nsf/allkb/4A9AF19480E50C6D862571B70058142A
使用PCI-6602和DAQmx,利用一个计数器产生一个可重触发的有限点数字脉冲序列
是否能够使用PCI-6602上的一个计数器,在DAQmx下编程实现创建一个有限点的数字脉冲序列?
URL:
http://digital.ni.com/public.nsf/allkb/BD6DED39DB0F86C0862573CA00429B37
在PCI-6602板卡上如何配置PFI线为数字I/O口?
在PCI-660x板卡上有8条线专门用来数字输入/输出的。但是手册上说通过配置一些计数器的PFI线,我可以得到额外的24条数字线。从软件上我如何实现呢?
URL:
http://digital.ni.com/public.nsf/allkb/618D8610203846DD4825716A000E7D4B
Utilisation des filtres numériques pour des compteurs en NI-DAQmx
Comment permettre l’utilisation des filtres numériques pour les cartes 66xx en NI-DAQmx
URL:
http://digital.ni.com/public.nsf/allkb/5D198BD140F04F678625714800639592
Determining in Hardware When the Terminal Count of a Counter is Reached
How can I determine in hardware when the terminal count of my counter is reached?
URL:
http://digital.ni.com/public.nsf/allkb/1FA39908C687A5F58625713C00064464
Error at Line Set Attribute for TIO Application
I have a Traditional DAQ Counter/Timer VI that worked in LabVIEW 6.1 but errors at Line Set Attribute in LabVIEW 8
URL:
http://digital.ni.com/public.nsf/allkb/47A14AF259407A3A8625712700027582
TIO 어플리케이션의 Line Set Attribute 에서의 에러.
LabVIEW 6.1 에서 사용하던 Traditional DAQ 카운터/타이머 VI 를 가지고 있는데 LabVIEW 8 에서는 Line Set Attribute 에서 에러가 발생합니다.
URL:
http://digital.ni.com/public.nsf/allkb/B84876747FDF3E41862571310001A63C
Global Positioning System (GPS) Timestamp from the PXI-6608 Shows a 90ms Delay
0. To return the accurate GPS timestamp, subtract 90 ms from the value measured by the PXI-6608.
URL:
http://digital.ni.com/public.nsf/allkb/C916F1749B938B28862571070083A4F1
NI-DAQmx で、カウンタの分周比を 2 に設定する方法
NI-DAQmx を使用して、NI-660x や NI-60xx シリーズのカウンタで分周する際、分周比を 2 に指定したいと考えています。NI-DAQmx の「DAQmxチャンネルの作成(CO-パルス生成-ティック)」の入力パラメータ low ticks と high ticks ともに最小値が 2 であるため、分周比は小さく
URL:
http://digital.ni.com/public.nsf/allkb/1B14A5035A982A6A862570ED001766EA
NI-DAQmx で、カウンタの分周比を 2 に設定する方法
NI-DAQmx を使用して、NI-660x や NI-60xx シリーズのカウンタで分周する際、分周比を 2 に指定したいと考えています。NI-DAQmx の「DAQmxチャンネルの作成(CO-パルス生成-ティック)」の入力パラメータ low ticks と high ticks ともに最小値が 2 であるため、分周比は小さく
URL:
http://digital.ni.com/public.nsf/allkb/31564837624B49BF862570ED0017B146
Sort by:
Date (Most recent)
Title (A-Z)
1-10 of
19
Next
Search KnowledgeBase Documents: