Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
KnowledgeBase

Category(s) Selected [start over]

Software
: Driver Software [remove] ,
Hardware
: Legacy DAQ Devices [remove] ,
31-40 of 41
KnowledgeBase [see results below]. To refine your results, select another category.
Software
NI-CAN (1)
NI-DAQ (40)
NI-DAQmx (1)
Hardware
Analog Input (2)
Digital I/O (7)
Multifunction DAQ (26)
Question Type
Bug Fix/ Error Message/ Error Code (13)
FAQ (4)
Install/Config (3)
Programming (13)
Specifications/ Documentation (7)
Unexpected Behavior/ Bad Reading (1)
Document Languages
English (30)
French (1)
Japanese (5)
Chinese (Simplified) (1)
Chinese (Traditional) (2)
Korean (2)

Sort by:
31-40 of 41
|
Can I Use SCXI with a DAQPad Product? Although the DAQPad-6020E can be configured for SCXI, USB is much slower bus, and it is not a recommended configuration. Parallel port DAQPads such as the DAQPad-1200 and the DAQPad-MIO-16XE-50 do not support SCXI. URL: http://digital.ni.com/public.nsf/allkb/2F0334259A9F5A42862565990082D249
How Do I Perform Handshaking with an 8255-Based Digital I/O Board (Lab/1200, DIO Boards)? How do I perform handshaking with an 8255-based Digital I/O board (Lab*, PCI-1200, PC-DIO-24, PC-DIO-96, etc.)? URL: http://digital.ni.com/public.nsf/allkb/5A2FBF42EF367C998625655900788838
How Do I Use the VI Digital Group Config.vi with the 8255 chip (lab*, PC-DIO*, etc.)? How does Digital Group Config.vi work with the 8255 based devices like the PC-DIO series? URL: http://digital.ni.com/public.nsf/allkb/C1C9B9F736A8B116862565590079437A
Error -10403 When Running DIGPrt.vbp Example with PC-516 I am running the DIGPrt.vbp example that ships with NI-DAQ (versions prior to 6.0). It returns error -10403 (Device Support Error) when using a PC-516. URL: http://digital.ni.com/public.nsf/allkb/B2209AF3738554768625654B006864CE
Why Do I Get Error -10010 with my NI 6533/6534 Board? If I configure the NI 6533/6534 for handshaking/pattern generation on one port and set the buffer size to an odd number of bytes, then I get error -10010. URL: http://digital.ni.com/public.nsf/allkb/323223711E9298DF862565450079DAB7
Misleading Error -10444 with the NB-A2000 I have an NB-A2000 for my Macintosh. If I try to perform an odd number of scans on a single channel, I get error message -10444 that states that I do not having enough available memory. URL: http://digital.ni.com/public.nsf/allkb/BCC38DA5129FA67A8625710F005A6D99
Misleading Error -10444 with the NB-A2000 I have an NB-A2000 for my Macintosh. If I try to perform an odd number of scans on a single channel, I get error message -10444 that states that I do not having enough available memory. URL: http://digital.ni.com/public.nsf/allkb/74FC439490204BFA8625628A0081E241
Why Does the DAQPad-MIO-16XE-50 Self Calibration Take Up To 75 Seconds? Why does the self calibration routine take around a minute to return when the manual states a few seconds? URL: http://digital.ni.com/public.nsf/allkb/DB0EBD5D7061A5A186256E8E0025140A
AT-MIO-16E-10 Causes Floppy Drive Failure at Boot-Up When Plugged into Machine My Dell Dimension is having trouble with a National Instruments AT-MIO-16E-10 DAQ board. When placed in the computer, it consistently gets a floppy drive controller failure. The floppy drive is configured for DMA 2: IRQ 6: address 3F0-3F7. If the E-10 board is removed, the problem goes away. URL: http://digital.ni.com/public.nsf/allkb/EDDE70959FD8B5F086256E8E0025136D
Can I Use the 1 MHz Internal Clock as the Source on the DAQCard-700? How do I use the internal 1Mhz clock on the DAQcard-700 as the source for counter 1 using NI-DAQ calls? URL: http://digital.ni.com/public.nsf/allkb/0D1DCF7561C751A586256E8E00250C50
Sort by: