Can I Use SCXI with a DAQPad Product?
Although the DAQPad-6020E can be configured for SCXI, USB is much slower bus, and it is not a recommended configuration. Parallel port DAQPads such as the DAQPad-1200 and the DAQPad-MIO-16XE-50 do not support SCXI.
URL: http://digital.ni.com/public.nsf/allkb/2F0334259A9F5A42862565990082D249
|
How Do I Perform Handshaking with an 8255-Based Digital I/O Board (Lab/1200, DIO Boards)?
How do I perform handshaking with an 8255-based Digital I/O board (Lab*, PCI-1200, PC-DIO-24, PC-DIO-96, etc.)?
URL: http://digital.ni.com/public.nsf/allkb/5A2FBF42EF367C998625655900788838
|
How Do I Use the VI Digital Group Config.vi with the 8255 chip (lab*, PC-DIO*, etc.)?
How does Digital Group Config.vi work with the 8255 based devices like the PC-DIO series?
URL: http://digital.ni.com/public.nsf/allkb/C1C9B9F736A8B116862565590079437A
|
Error -10403 When Running DIGPrt.vbp Example with PC-516
I am running the DIGPrt.vbp example that ships with NI-DAQ (versions prior to 6.0). It returns error -10403 (Device Support Error) when using a PC-516.
URL: http://digital.ni.com/public.nsf/allkb/B2209AF3738554768625654B006864CE
|
Why Do I Get Error -10010 with my NI 6533/6534 Board?
If I configure the NI 6533/6534 for handshaking/pattern generation on one port and set the buffer size to an odd number of bytes, then I get error -10010.
URL: http://digital.ni.com/public.nsf/allkb/323223711E9298DF862565450079DAB7
|
Misleading Error -10444 with the NB-A2000
I have an NB-A2000 for my Macintosh. If I try to perform an odd number of scans on a single channel, I get error message -10444 that states that I do not having enough available memory.
URL: http://digital.ni.com/public.nsf/allkb/BCC38DA5129FA67A8625710F005A6D99
|
Misleading Error -10444 with the NB-A2000
I have an NB-A2000 for my Macintosh. If I try to perform an odd number of scans on a single channel, I get error message -10444 that states that I do not having enough available memory.
URL: http://digital.ni.com/public.nsf/allkb/74FC439490204BFA8625628A0081E241
|
Why Does the DAQPad-MIO-16XE-50 Self Calibration Take Up To 75 Seconds?
Why does the self calibration routine take around a minute to return when the manual states a few seconds?
URL: http://digital.ni.com/public.nsf/allkb/DB0EBD5D7061A5A186256E8E0025140A
|
AT-MIO-16E-10 Causes Floppy Drive Failure at Boot-Up When Plugged into Machine
My Dell Dimension is having trouble with a National Instruments AT-MIO-16E-10 DAQ board. When placed in the computer, it consistently gets a floppy drive controller failure. The floppy drive is configured for DMA 2: IRQ 6: address 3F0-3F7. If the E-10 board is removed, the problem goes away.
URL: http://digital.ni.com/public.nsf/allkb/EDDE70959FD8B5F086256E8E0025136D
|
Can I Use the 1 MHz Internal Clock as the Source on the DAQCard-700?
How do I use the internal 1Mhz clock on the DAQcard-700 as the source for counter 1 using NI-DAQ calls?
URL: http://digital.ni.com/public.nsf/allkb/0D1DCF7561C751A586256E8E00250C50
|