How Do I Set Interface Name for the Camera on Each Port of PCIe-1430?
I have two camera connected to my Dual Channel Camera Link PCIe-1430. How do I set the Interface Names in LabVIEW to acquire from each of the cameras?
URL: http://digital.ni.com/public.nsf/allkb/B1C76A5D193637988625741100753E60
|
Smart Camera: Incorrect Time Server Configured when Suggest Values Button is Pressed for Static IP Configuration in MAX
I would like to assign a static IP address to my Smart Camera. When I select the 'Suggest Values' button in Measurement and Automation Explorer (MAX), it assigns the proper IP address to my smart camera. However, it also assigns an IP address as the Time Server. However that IP address is invalid
URL: http://digital.ni.com/public.nsf/allkb/38FF0846DC314031862573AE0058F7A6
|
Serial Communication Using a Compact Vision System (CVS)
What software do I need to perform serial communication between my Compact Vision System (CVS) and another serial device?
URL: http://digital.ni.com/public.nsf/allkb/4583C7995E571B558625739A000302EA
|
Why does my CVS not Display My FireWire Camera When I Expand Devices and Interfaces? Do I have to Refresh (F5) Everytime?
I have connected my FireWire camera to the CVS and in Measurement and Automation Explorer (MAX), I expand the Devices and Interfaces node for the CVS but I only see my Reconfigurable I/O (RIO) part. The camera does not appear. However, if I refresh by pressing F5 or selecting it from the menu, the
URL: http://digital.ni.com/public.nsf/allkb/9A99245C7EE29B3A862573990059A537
|
Why can I see my CVS in MAX but not in LabVIEW 8.0?
I installed NI-IMAQdx and/or NI-IMAQ for IEEE 1394 cameras on my host computer. When I connect my CVS to the network, I can see it in MAX after refreshing. However, if I open LabVIEW and try to create a target, the option for searching for CVS units does not appear. How can I connect to my CVS from
URL: http://digital.ni.com/public.nsf/allkb/6354A02D073C4EB38625730500504D1F
|
Drive a Control Line High or Low in the Camera File
I have an NI Frame Grabber, like the PCI-1422, and I am making my own camera file. I would like to know how to toggle the polarity of the control lines on my image acquisition board. I do not want to just toggle the line or send a pulse, but rather set it high or low. How can I drive my
URL: http://digital.ni.com/public.nsf/allkb/4E6F9A0BDAE9BFDB862572D80053DFB7
|
在 Camera File 中將控制訊號設定為 High 或 Low
我有一張 NI 的影像擷取卡(Frame Grabber),像 PCI-1422,而我要建立自己的 camera file。我想要知道如何改變影像卡上控制訊號的高低電位。我並不只是要改變訊號電位或是送出一個脈衝,而是要將其設定為 high 或 low。我該如何利用 camera file 驅動我的控制訊號為 high ■>
URL: http://digital.ni.com/public.nsf/allkb/93A99571E613EE818625735B0031AEC0
|
Asynchronous Reset Mode With Pulnix TM-9701 Progressive Scan Camera
How do I setup my Pulnix TM-9701 to operate in Asynchronous Reset Mode?
URL: http://digital.ni.com/public.nsf/allkb/DBA3EB2EBB5041D5862572D0000C0D28
|
IMAQ Error -1074397151 When Changing an Analog Attribute During a Grab
I have an analog NI-IMAQ frame grabber that I am acquiring images from in LabVIEW, and I would like to change an Analog Attribute while grabbing my images. For example I would like to be able to change my White Reference Voltage while acquiring my images so that I can adjust the reference
URL: http://digital.ni.com/public.nsf/allkb/00B08A85411BD0E7862572A00077DDCD
|
Trigger Lines on the PCIe-1429 and PCIe-1430
I see there is a trigger line on the front of the PCIe-1429 and the PCIe-1430 that has an SMB connector. What trigger input value does this SMB trigger connection use, and where are the other trigger lines located?
URL: http://digital.ni.com/public.nsf/allkb/89FE1F13963E529C86257287002052B1
|