Cart
|
Help
NI Home
>
Support
> KnowledgeBase
KnowledgeBase
Select your country
Category(s) Selected
[
start over
]
Software
: LabVIEW Development Systems [
remove
] ,
Hardware
: SCXI [
remove
] ,
1-10 of
14
KnowledgeBase [
see results below
]. To refine your results, select another category.
Software
Base Package
(4)
Full Development System
(6)
Professional Development System
(5)
Hardware
Chassis
(2)
Modules
(7)
Terminal Blocks
(2)
Question Type
Bug Fix/ Error Message/ Error Code
(1)
FAQ
(2)
Programming
(8)
Specifications/ Documentation
(3)
Document Languages
English
(11)
Chinese (Traditional)
(1)
Korean
(2)
Search KnowledgeBase Documents:
Sort by:
Date (Most recent)
Title (A-Z)
1-10 of
14
Next
Can I Use One SCXI Module in Multiple LabVIEW Applications at the Same Time?
Can I use one SCXI module in multiple LabVIEW applications that will run simultaneously? Each application is specific to a certain test setup, but each test setup uses different channels on an SCXI card using one DAQ card.
URL:
http://digital.ni.com/public.nsf/allkb/55FDCBF1CA929B268625726E007EA229
Error 10003 occurs when performing SCXI_SCAN_Config or SCXI_SCAN_Setup.
Why do I get error -10003 when I call SCXI_SCAN_Config or SCXI_SCAN_Setup with a call library function node?
URL:
http://digital.ni.com/public.nsf/allkb/B70F0E818A4F653A862571E6006E43A7
SCXI_SCAN_Config 또는 SCXI_SCAN_Setup을 할때 10003 에러가 발생합니다.
라이브러리 함수 호출 노드로(call library function node) SCXI_SCAN_Config 또는 SCXI_SCAN_Setup을 호출할때 10003 에러가 왜 발생합니까?
URL:
http://digital.ni.com/public.nsf/allkb/8E090735582DC89C86257204002F526D
How to do a Null-Offset Calibration for Full-Bridge Absolute Transducers (SCXI-1520 / PXI-4220) with the DAQ Assistant?
The DAQ Assistant does not provide a way to do any calibration for Full-Bridge Absolute Transducers that are not strain gauges (for example load cells) for a NI-DAQmx Tasks / Global Channels created in MAX.If I use the example VI located in the example finder ( Browse According to
URL:
http://digital.ni.com/public.nsf/allkb/3593FEAB432C2B0C8625713E0059E5E9
Why Am I Getting a 'No Explicit Path Found Between the Two Channels' Error?
I initially wrote a program to connect two channels in the SCXI module in matrix mode. During the testing phase, the connectivity of the route created was checked and the path was indeed created. However when I write another program to disconnect the channels I get an error that no explicit
URL:
http://digital.ni.com/public.nsf/allkb/3C291003766C61A086256FE40048BC8D
Accessing Strain Gage Calibration Information Set in MAX
I calibrated my strain gage(s) when I created NI-DAQmx Channels in Measurement and Automation Explorer (MAX). How can I retrieve this information to save to file or to display to my user?
URL:
http://digital.ni.com/public.nsf/allkb/E7588504B22DF07E86256FC60081755F
Error -713 When Writing to TEDS EEPROM
I am trying to write to the EEPROM of a TEDS sensor connected to a 1314T terminal block on a SCXI-1520 in an SCXI chassis, using an example that I downloaded from the web. I keep getting Error -713 "No EEPROM is detected." After
URL:
http://digital.ni.com/public.nsf/allkb/1BF6BC36A125E5E586256FA900692DF2
SCXI 와 SCC 에 대한 DAQmx Base의 지원
DAQmx Base에서 SCXI 또는 SCC 모듈을 사용할 수 있습니까?
URL:
http://digital.ni.com/public.nsf/allkb/93DDD75850968729862571A70020B4F3
為什麼在我的DAQmx Base Configuration Utility中看不到SCXI模組設定?
我要用DAQmx Base並且透過SCXI來擷取訊號,但我卻無法在DAQmx Base Configuration Utility中顯示出SCXI的模組出來。
URL:
http://digital.ni.com/public.nsf/allkb/79F67CB6240E65C98625700D0002B49D
Checking the SCXI Gain Set by Traditional NI-DAQ in LabVIEW
Traditional NI-DAQ automatically sets the optimal gains for my SCXI module based on the input limits I specify. How can I check these gain values?
URL:
http://digital.ni.com/public.nsf/allkb/C8CDCBFA6E13A7F586256ECF0073C36B
Sort by:
Date (Most recent)
Title (A-Z)
1-10 of
14
Next
Search KnowledgeBase Documents: