Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
KnowledgeBase

Category(s) Selected [start over]

Software
: LabVIEW Development Systems [remove] ,
Hardware
: Digital I/O (DIO) [remove] ,
1-10 of 21
KnowledgeBase [see results below]. To refine your results, select another category.
Software
Base Package (1)
Full Development System (3)
Professional Development System (14)
Hardware
High-Speed (10)
Isolated (7)
Static (8)
Question Type
FAQ (1)
Install/Config (1)
Programming (6)
Specifications/ Documentation (8)
Unexpected Behavior/ Bad Reading (5)
Document Languages
English (11)
Japanese (3)
Chinese (Simplified) (3)
Chinese (Traditional) (1)
Korean (3)

Sort by:
1-10 of 21
NI-HSDIO Dynamic Generation and Acquisition Shipping Example Triggering I am developing an application based upon the NI-HSDIO shipping example 'Dynamic Generation and Acquisition-Source Synchronous.vi'. In this example, the generation session is configured to export the Data Active Event to PFI 1 to serve as a start trigger for the acquisition session. The example URL: http://digital.ni.com/public.nsf/allkb/F6BE8B5B5588B60C8625723C006A240F
NI-HSDIO Dynamic Generation and Acquisition 範例程式 我在開發一個程式,是由 NI-HSDIO 範例程式 "Dynamic Generation and Acquisition-Souce Synchronous.vi" 修改而來,在這個範例中,負責做輸出的裝置被設定成輸出 Data Active Event 給 PFI 1 當作其他擷取裝置的 start trigger,這代表使用者必須要外部接線從 PFI 1 到 PFI 2 ,擷取裝置 URL: http://digital.ni.com/public.nsf/allkb/E917633EB4FA484D862573BB0022F688
看门狗定时器工作不正常 我正在使用PCI-6515工业数字IO板卡上的看门狗定时器功能,使得我的系统的数字输出在软件崩溃时能被设置为安全模式。但是,当程序被停止、取消、关闭或者LabVIEW退出时,数字输出并没有被设置为安全模式。看门狗功能仅仅在程序暂停或者计算机系统崩溃时 URL: http://digital.ni.com/public.nsf/allkb/7C803EBFCC439382862572240035662E
在LabVIEW7.1的NI-HSDIO1.4的niHSDIO Session Initialiation VI驱动中没有产生资源名 我在使用LabVIEW7.1或更老版本,现在安装了NI-HSDIO1.4 (或更新的版本)。为什么niHSDIO Init Acquisition/Generation Session的资源名没有自动出现? URL: http://digital.ni.com/public.nsf/allkb/D7E055B40DDC854B482571DC000CD31E
HSDIO在使用外时钟时,动态发生产生错误的输出。 为什么当HSDIO使用外部时钟时,动态输出的信号是错误的?我把一个超过50MHz的信号接给了CLK IN,但是数字输出为60mV或是没有输出。 URL: http://digital.ni.com/public.nsf/allkb/83275E0EF860EBE2482571C000159C54
HSDIO Dynamic Generation with External Clock Gives Incorrect Output Why am I seeing an incorrect output when I dynamically generate a signal with an external clock on my HSDIO device? I am sending a reference clock above 50 MHz to CLK IN, but the digital output is only 60mV or nothing at all. URL: http://digital.ni.com/public.nsf/allkb/884C5A76BA1A474E8625717A0068AA09
외부클럭을 이용한 HSDIO 다이나믹 생성을 하면 잘못된 출력이 나옴. 왜 외부클럭을 이용한 HSDIO 다이나믹 생성을 하면 잘못된 출력이 나옵니까? CLK IN에 50MHz 이상의 참조클럭 보내고 있으나, 디지털 출력은 60mV만 나오거나 혹은 전혀 나오지 않습니다. URL: http://digital.ni.com/public.nsf/allkb/EFFA706F2C658D8F8625719A0001DFC2
USB-6501の出力ドライブタイプ(アクティブドライブとオープンコレクタ) USB-6501を使って、5VのTTLではなく、3.3V(LVTTL, Low Voltage TTL)の信号を出力しようとしています。マニュアルに、ソフトウェアを使って、デフォルトのオープンコレクタ(Open Collector, TTL)をアクティブドライブ(Active Drive, LVTTL)に設定することができるとあります。 ど URL: http://digital.ni.com/public.nsf/allkb/A9A23C432DA402508625722E00063919
USB-6501 Benchmarks with NI-DAQmx Problem: What are the benchmarks for the USB-6501? Solution: The data transfer rates of the USB-6501 are software timed, also called unstrobed or nonlatched, and do not require status and control signals so the transfer speed are completely software/computer dependent. URL: http://digital.ni.com/public.nsf/allkb/376BBB979269F9C5862570F7006A030F
USB-6501를 NI-DAQmx로 밴치마크 이들 속도는 프로그래밍 언어와 코드의 효율성, CPU 사용, 데이터 전송방법 등등에 의해 변동될 수 있습니다. 아래는 USB-6501로 10,000번의 업데이트를 테스트한 밴치마크 결과입니다. URL: http://digital.ni.com/public.nsf/allkb/4DA471790687E5B2862571070005CB65
Sort by:
1-10 of 21