Error -200251: 'No DMA Channels Available' When Using Multiple Counters I am doing more than three simultaneous counter input tasks on a NI 6602 or NI 6608, or I am doing more than one simultaneous counter input task on a PCI-6601. After adding an additional task and running, the following error occurs at DAQmx Start URL: http://digital.ni.com/public.nsf/allkb/6503B2EFA2CB867186257219007DB643
当使用多个计数器的时候发现错误-200251:“没有多余的DMA通道(No DMA Channels Available)” 我再NI 6602或者NI 6608上采用多于三个计数器同时进行计数器输入的任务。或者在PCI-6601上采用超过一个计数器进行计数器输入的任务。 当我再添加一个任务并开始运行的时候,在DAQmx Start Task中出现了以下错误: URL: http://digital.ni.com/public.nsf/allkb/E885F195EE56A42B862573CA00439E9D
複数カウンタを使用する際、エラーー200251が出ますがなぜでしょうか。 PCI-6601及びPCI-6602またPCI-6608を使用して、それぞれ2つ及び4つ以上の同時カウンタ入力タスクを作成しています。このVIを実行しますと、DAQmx Start Task VIからー200251のエラーが出ます。エラーの内容としては、DMAチャネルまたはUSBバルク終了点が無効■> URL: http://digital.ni.com/public.nsf/allkb/7AC693B7676D4F4086257385003F0FFB
Utilisation des filtres numériques pour des compteurs en NI-DAQmx Comment permettre l’utilisation des filtres numériques pour les cartes 66xx en NI-DAQmx URL: http://digital.ni.com/public.nsf/allkb/5D198BD140F04F678625714800639592
PXI-6602で複数のカウンタで同時に有限パルスを発生させようとするとエラー50103が発生するのはどうしてですか? PXI-6602で複数のカウンタで同時に有限パルスを発生させようとするとエラー50103が発生します。連続の場合は発生しません。どうしてですか? URL: http://digital.ni.com/public.nsf/allkb/B049F379E7680D2886256F4F0008D9C6
Why Can't I Choose the Internal Clock on the Counter Example Program 'Meas Angular Position-Buffered-Cont-Ext Clk.vi'? The Counter Example Program 'Meas Angular Position-Buffered-Cont-Ext Clk.vi' is found in the LabVIEW Example Finder under: Hardware Input and Output»DAQmx»Counter Measurements»Position. The example program is the simplest way to acquire buffered signals from three quadrature encoders and translate URL: http://digital.ni.com/public.nsf/allkb/63AE9149A2AEF85A86256F2B005D0E7D
LabVIEWとカウンターボード(TIO)を使用して、従来型DAQでデジタル入出力をするにはどうすればいいですか? カウンターボード(660xシリーズ)を使用しています。LabVIEWで従来型DAQ関数を使用して、デジタル入出力をしたいのですが、660xシリーズ用のサンプルプログラムが見つかりません。どのようにプログラムを作成すればいいですか? URL: http://digital.ni.com/public.nsf/allkb/5BD17508728F80A586256F0A004A6FE7