Cart
|
Help
NI Home
>
Support
> KnowledgeBase
KnowledgeBase
Select your country
Category(s) Selected
[
start over
]
Software
:
Other NI Software
/ VirtualBench [
remove
] ,
31-40 of
83
KnowledgeBase [
see results below
]. To refine your results, select another category.
Hardware
Industrial Communications
(1)
Modular Instruments
(1)
SCXI
(2)
Question Type
Bug Fix/ Error Message/ Error Code
(6)
FAQ
(2)
Install/Config
(6)
Programming
(61)
Specifications/ Documentation
(4)
Unexpected Behavior/ Bad Reading
(4)
Document Languages
English
(77)
Spanish
(2)
Japanese
(2)
Korean
(2)
Search KnowledgeBase Documents:
Sort by:
Date (Most recent)
Title (A-Z)
31-40 of
83
Previous
|
Next
VirtualBench-Logger Logs Extra Entries When I am using a Thermocouple with Cold-Junction Compensation
When I am measuring temperatures with thermocouples and using a Cold-Junction Compensation (CJC) sensor in VirtualBench-Logger, I have extra entries in my log file about every 25 seconds. For reference, this is when my CJC is read.
URL:
http://digital.ni.com/public.nsf/allkb/862567530005F09C8625678D0074808A
Why Does My Waveform Degrade When I Change the Vertical Position in VirtualBench-Scope?
I'm reading 0.6 V peak-peak sine wave in VirtualBench-Scope with 0.0 V vertical position and 0.1 Volts/Div, however when I move the Vertical Position of the wave form up or down 0.2 V my signal becomes noisy or looks worse. Isn't this just adding a constant offset in software?Why
URL:
http://digital.ni.com/public.nsf/allkb/862567530005F09C8625678A0076E257
Why does VirtualBench-Logger Log Data Every 168 Seconds When I Specify a Larger Time Interval?
Using a E-Series DAQ board I specified a Time Interval Setting of 300 seconds (5 minutes) in the VirtualBench-Logger. However looking at my log file and timing the update rate on the screen, the data is actually being collected every 167.7 seconds. It seems that no matter what value I use the
URL:
http://digital.ni.com/public.nsf/allkb/862567530005F09C8625678A006C5DED
I Can't Find a Digital Trigger Option for the NI 5911 in VirtualBench-Scope
In VirtualBench-Scope 2.5 with the NI 5911 Oscilloscope/Digitizer, there doesn't seem to be a way to turn on the digital trigger. The SRC control for the trigger only has 'Immed' and 'CH1' as options.
URL:
http://digital.ni.com/public.nsf/allkb/862567530005F09C86256786008319A9
VirtualBench-Logger 2.5 will not Load Log Files Correctly for Replay
When trying use the File » Replay Data to load a log file saved in VirtualBench-Logger 2.5, I get a message about 'the file not being a 2.1 log file' even though I am using VirtualBench-Logger 2.5 for creating and replaying the file.
URL:
http://digital.ni.com/public.nsf/allkb/862567530005F09C86256786006DECDF
Thermocouple Measurement Configuration is Incorrect for the SCC-TC0x Modules in VirtualBench-DMM 2.1.2
To configure a thermocouple temperature measurement reading in the VirtualBench-DMM a user must specify the CJC source and CJC channel.When using the SCC-TC0x modules the CJC signal comes in on channel x+8. When this channel is selected in the configuration the measured value is incorrect.
URL:
http://digital.ni.com/public.nsf/allkb/862567530005F09C862567610070C464
Thermocouple Reading Accuracy Degrades when Configuring Extra Channel for VDC in VirtualBench-Logger 2.1.2
While using VirtualBench-Logger 2.1.2 to measure thermocouples on 6 channels of a system (using an SCXI-1100 and NI-DAQ 6.1.1), all of my readings are correct. Why does the the accuracy of the temperature readings seriously degrade as soon as I configure an extra channel to measure DC voltage?
URL:
http://digital.ni.com/public.nsf/allkb/862567530005F09C8625674E007F3E15
VirtualBench-Arb 2.1.1 is not Detecting my PCI-6711 or PCI-6713 Board.
I can see my board in NI-DAQ configuration and it tests out okay. I can even use my board in LabVIEW, CVI or other programming languages. However VirtualBench does not list my board as one to choose from in the Settings.
URL:
http://digital.ni.com/public.nsf/allkb/862567530005F09C8625673D00739FA6
Why Does My SCXI-1127 Switch Not Appear in the SCXI Module List for VirtualBench-DMM 2.51?
Why does my SCXI-1127 Switch not Appear in the SCXI module list for VirtualBench-DMM 2.51?
URL:
http://digital.ni.com/public.nsf/allkb/862567530005F09C86256732006D952F
왜 저의 SCXI-1127이 VirtualBench-DMM 2.51의 SCXI모듈목록에서 보이지 않습니까?
왜 저의 SCXI-1127이 VirtualBench-DMM 2.51의 SCXI모듈목록에서 보이지 않습니까?
URL:
http://digital.ni.com/public.nsf/allkb/22D24CD4BD9C2C2F86256EA5001842DC
Sort by:
Date (Most recent)
Title (A-Z)
31-40 of
83
Previous
|
Next
Search KnowledgeBase Documents: