Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
KnowledgeBase

Category(s) Selected [start over]

Software
: Other NI Software / VirtualBench [remove] ,
21-30 of 83
KnowledgeBase [see results below]. To refine your results, select another category.
Hardware
Industrial Communications (1)
Modular Instruments (1)
SCXI (2)
Question Type
Bug Fix/ Error Message/ Error Code (6)
FAQ (2)
Install/Config (6)
Programming (61)
Specifications/ Documentation (4)
Unexpected Behavior/ Bad Reading (4)
Document Languages
English (77)
Spanish (2)
Japanese (2)
Korean (2)

Sort by:
21-30 of 83
|
How can I Change the Number of Digits Displayed when Values are shown in VirtualBench-Logger. When I select the Values instead of the Labels in the bottom right hand corner of VirtualBench-Logger the channel names change to their values at the cursor, but I want to be able to set how many digits are shown. URL: http://digital.ni.com/public.nsf/allkb/5B2398BFE4540DE48625684100749844
How can I use my SCC-A10 Modules with VirtualBench-Scope? If you configure the SCC-2345 as an accessory for your Data Acquisition board and a SCC-A10 for a particular channel in the Measurement and Automation Explorer, then the NI-DAQ driver will automatically return a voltage reading on the order of +/- 100 V. This causes VirtualBench to report an over URL: http://digital.ni.com/public.nsf/allkb/E734E4CE79BD36E3862567D8005E560B
VirtualBench and Multiple SCXI Chassis Configurations I would like to use more than one SCXI chassis in my VirtualBench application. Can I do a multi-chassis SCXI configuration with VirtualBench? URL: http://digital.ni.com/public.nsf/allkb/D5F454FCF718104E862567D3004EE9FC
Virtualbench: Software Instruments in the Startup Bar Some of the software instruments that are mentioned in the manual aren't showing up in the Virtualbench 2.1.1 Startup Bar. Where are they? URL: http://digital.ni.com/public.nsf/allkb/A395F53B524AD67686256E8E00229AB2
Problems with the PCI-6024E and PCI-6025E in VirtualBench-Function Generator I am using a Low Cost PCI E Series DAQ Board (PCI-6024E or PCI-6025E) and VirtualBench-Function Generator to generate sine waves and square waves. I configure the wave the way I want it, and then I press the On button. I see the waveform being generated on my output for just a short time URL: http://digital.ni.com/public.nsf/allkb/DED305D58D98F1A7862567AD004964FD
Noise on Lower Voltage Signals with a 1200 Series DAQ Card I have a PCI-1200 that I am using to measure a thermocouple (+10 mV to -10 mV), another 30 mV signal, and two signals that range from +5 V to -5V. When I use VirtualBench-DMM to measure my signals, there is very little noise. However when I use VirtualBench-Logger to read my four signals, the two URL: http://digital.ni.com/public.nsf/allkb/3D1D49000EED697D862567A8004B25E7
Logging Data at a Specific Rate with VirtualBench-Logger and NI 435x I want to log my data readings to disk every minute with VirtualBench-Logger and my NI 4350. I can specify to log every X intervals, but for the reading rate my choices are 'Fast' and 'Slow'. How does this translate into seconds or time? URL: http://digital.ni.com/public.nsf/allkb/720BEF2AFD4383BB862567A60076DC33
How do I Configure VirtualBench-DMM to Read Thermocouples on a DAQPAD-MIO-16XE-50 with a DAQPAD-TB-52 Connector? I am having trouble reading my thermocouple measurements with my DAQPAD-MIO-16XE-50 that has a DAQPAD-TB-52 connector adapter. I cannot seem to get the settings correct in VirtualBench-DMM. URL: http://digital.ni.com/public.nsf/allkb/862567530005F09C86256790005B5C2D
Measuring Temperatures with VirtualBench-DMM I am trying to use VirtualBench-DMM to measure temperature using a thermocouple. What settings must I configure? URL: http://digital.ni.com/public.nsf/allkb/862567530005F09C862567900059B11E
Where are VirtualBench-AODC & VirtualBench-DIO in VirtualBench Suite 2.51? I've just uninstalled my old version of VirtualBench and installed VirtualBench 2.51 and can't find VirtualBench-AODC and VirtualBench-DIO. URL: http://digital.ni.com/public.nsf/allkb/862567530005F09C862567900062BA67
Sort by:
21-30 of 83
|