Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
KnowledgeBase

Category(s) Selected [start over]

Software
: LabVIEW Modules [remove] ,
Hardware
: CompactRIO [remove] ,
31-40 of 86
KnowledgeBase [see results below]. To refine your results, select another category.
Software
DSC Module (5)
FPGA Module (48)
Real-Time Module (43)
Hardware
Chassis (Backplanes) (17)
Controllers (41)
Analog Input Modules (9)
Digital Input Modules (3)
Digital Output Modules (3)
Question Type
Bug Fix/ Error Message/ Error Code (15)
FAQ (18)
Install/Config (16)
Programming (23)
Specifications/ Documentation (8)
Unexpected Behavior/ Bad Reading (6)
Document Languages
English (41)
Spanish (6)
Japanese (7)
Chinese (Simplified) (17)
Chinese (Traditional) (8)
Korean (7)

Sort by:
31-40 of 86
|
¿Por qué no Puedo Instalar LabVIEW Real-TIME 8.20 en mi Controlador cRIO-9014 desde MAX? Tengo LabVIEW 8.20 y un controlador cRIO-9014. Lo he estado utilizando por varios meses; recientemente le di formato y encontré que no puedo instalar el software desde Measurement and Automation Explorer (MAX). ¿Por qué no puedo instalar LabVIEW Real-TIME 8.20 en mi controlador cRIO-9014 desde MAX? URL: http://digital.ni.com/public.nsf/allkb/E95A3C2ADB5E3FF5862572A600545534
Usando un FPGA de CompactRIO como Target sin el Módulo de Tiempo Real de LabVIEW Tengo un controlador CompactRIO 90xx y un chassis FPGA cRIO-910x. Quiero desarrollar y correr mi código FPGA en el chassis 910x directamente desde mi computadora de desarrollo sin el módulo de Tiempo Real de LabVIEW instalado. ¿Cómo lo hago? URL: http://digital.ni.com/public.nsf/allkb/014482714F323C5B862572A6000E6249
¿Cómo Reiniciar un Controlador CompactRIO Programáticamente? Me gustaría poder reiniciar programáticamente mi controlador CompactRIO. ¿Es posible? URL: http://digital.ni.com/public.nsf/allkb/80324C6DDAEC98D1862572A3006344AF
CRIO-9012 컨트롤러에서 NI 985x CAN Modules for Compact Rio 의 사용 CRIO-9012 컨트롤러에서 NI 985x CAN Modules for Compact Rio 를 사용하려고 하는데 CRIO-9012 컨트롤러에 소프트웨어를 설치할 때, NI-CAN 드라이버가 나타나지 않습니다. 무엇이 잘못된 것입니까? URL: http://digital.ni.com/public.nsf/allkb/991636543D7EA2FD862572A500052807
How to use 985x CAN C-series modules with a cRIO-901x VxWorks Controller I am trying to use a NI 985x CAN Module for CompactRIO with a cRIO-901x VxWorks controller, however the NI-CAN driver does not appear as an option while installing software on the cRIO-901x real time controller. What could be wrong? URL: http://digital.ni.com/public.nsf/allkb/804FC636F172426A8625729F00185149
Why Can I Not Install LabVIEW Real-Time 8.20 on My cRIO-9014 Controller from Measurement and Automation Explorer? I currently have LabVIEW 8.20 and have received a cRIO-9014 controller. I have been using it for several months and have recently re-formatted the controller and find I am now unable to install software from Measurement and Automation Explorer (MAX). Why can I not install LabVIEW Real-Time URL: http://digital.ni.com/public.nsf/allkb/A37F2EFFA7FE694D86257290007061D4
我为什么不能从MAX中对cRIO-9014控制器安装LabVIEW Real-Time 8.20? 我目前有LabVIEW 8.20并且获得了cRIO-9014 控制器。我已经使用了几个月,并且最近重新格式化了控制器,发现我无法从Measurement and Automation Explorer (MAX)安装软件。为什么我不能从MAX中为cRIO-9014控制器安装LabVIEW Real-Time 8.20? URL: http://digital.ni.com/public.nsf/allkb/16C79535528E660B8625737C004736D7
Unresolved Dependencies Error when Installing Software to cFP, cRIO, or PXI Targets I am trying to install LabVIEW Real-Time software on my target cRIO, cFP, or PXI Real-Time device. When I right click and click Add/Remove Software on my remote system and select LabVIEW Real-Time or other software, it gives me an error, “Cannot continue because of the URL: http://digital.ni.com/public.nsf/allkb/961D2DC5BB2991F88625727A00736A7F
Why Does My cRIO 9012 not Observe the Local Timezone? I'm trying to configure the timezone on a cRIO-9012 by setting the local time and then setting the date. After I set the date, the local time has jumped forward X number of hours, where X is the hour difference between local time and UTC time. URL: http://digital.ni.com/public.nsf/allkb/8C39040AAD9354818625722100654726
MAX Error 56 When Communicating With a LabVIEW Real-Time Controller I receive Error 56 in Measurement and Automation Explorer (MAX) when I try communicating with my Real-Time controller. My controller is connected with a cross-over cable. The error occurs in one or more of the following URL: http://digital.ni.com/public.nsf/allkb/922DDC440FCB15048625719D006FCB97
Sort by:
31-40 of 86
|