Cart
|
Help
NI Home
>
Support
> KnowledgeBase
KnowledgeBase
Select your country
Category(s) Selected
[
start over
]
Software
: LabVIEW Modules [
remove
] ,
Hardware
: CompactRIO [
remove
] ,
1-10 of
72
KnowledgeBase [
see results below
]. To refine your results, select another category.
Software
DSC Module
(4)
FPGA Module
(40)
Real-Time Module
(37)
Hardware
Chassis (Backplanes)
(13)
Controllers
(37)
Analog Input Modules
(5)
Digital Input Modules
(3)
Digital Output Modules
(3)
Question Type
Bug Fix/ Error Message/ Error Code
(15)
FAQ
(12)
Install/Config
(16)
Programming
(16)
Specifications/ Documentation
(7)
Unexpected Behavior/ Bad Reading
(6)
Document Languages
English
(33)
Spanish
(5)
Japanese
(5)
Chinese (Simplified)
(15)
Chinese (Traditional)
(7)
Korean
(7)
Search KnowledgeBase Documents:
Sort by:
Date (Most recent)
Title (A-Z)
1-10 of
72
Next
Why Does the cRIO Hangs when Resetting the Controller with System Reset?
When I set the System Reset IO to TRUE on the FPGA, my cRIO hangs. Why does this happen?
URL:
http://digital.ni.com/public.nsf/allkb/C3B8A3D27D676FA08625744200528D94
Error -63001 NI-RIO FPGA Communications Occurs With DMA Transfers From Host to FPGA
I am trying to do a DMA transfer from the 900x cRIO RT controller to the cRIO FPGA. The FPGA code compiles. However, when I run the code I get a Real-Time error saying the following: Error -63001: NI-RIO FPGA Communications.Framework: (Hex
URL:
http://digital.ni.com/public.nsf/allkb/257AF49E2110630F8625741F0062D292
在运行FPGA VI时会收到一条“Invalid Bitfile”的错误消息
在试图运行FPGA VI时,收到一条"Invalid Bitfile"的错误消息,而这个VI是刚刚被编译过的。为什么这个位流文件是无效的?
URL:
http://digital.ni.com/public.nsf/allkb/CE5D1BAFB3CEF3C88625742B0005D766
Why Do I See Large Binary Values Coming From Coming from My Analog FPGA Reading
I am seeing raw binary data that is outside of the range of my analog device.
URL:
http://digital.ni.com/public.nsf/allkb/7829D061AB7EF7F1862573E100702A2C
ホストからFPGAにDMA転送する時にエラー-63001が発生します。
cRIOのホスト(RT)側からcRIOのFPGA側へのデータ転送にDMA転送を行おうと考えています。そのため、LabVIEWのプロジェクトエクスプローラのFPGAターゲットでFIFOを作成し、プロパティでTypeの項目をHost to Target - DMAに設定し、FIFOを作成■>
URL:
http://digital.ni.com/public.nsf/allkb/148D9EDAF7A3BE3E862573850043C395
cRIOからホストPCへのデータ転送方法
cRIOのデータをホストPCに転送しようと思っています。どのように行うのが高速ですか?
URL:
http://digital.ni.com/public.nsf/allkb/C02EB78B17E1EACE8625734E0005D1EC
What is a Recommended Software Set?
I installed the August 2007 Driver CD and the LabVIEW Real-Time Software Wizard has changed. I now have the option to install recommended software sets. What are they, and why are some of them disabled? How do I install a set of software that includes software that is not in one of
URL:
http://digital.ni.com/public.nsf/allkb/A0B2AEDA76A029DC8625731B0057A16E
VxWorks Targets Do Not Honor New Daylight Savings Time Rules
Recently, the rules for Daylight Savings Time start and stop have changed. My VxWorks-based controller (such as the cRIO 901x series) seems to be an hour off sometimes. How do I correct this?
URL:
http://digital.ni.com/public.nsf/allkb/7E5CB910B1685C8B8625731A005FCB62
LabVIEW Runtime error in MAX when accessing a cRIO-901x with LabVIEW Real-Time 8.5 from MAX 4.2.1 or earlier
When attempting to expand the Software tab in MAX on a cRIO-901x I get several error message for my controllers that have LabVIEW Real-Time 8.5 installed. One of these error messages indicates an error starting the LabVIEW Runtime and says to reinstall your product and then contact National
URL:
http://digital.ni.com/public.nsf/allkb/1584D952E54ABB59862572F7006F3438
当我在MAX 4.2.1或更早版本上使用装有LabVIEW Real-Time 8.5的cRIO-901x时,出现LabVIEW Runtime error
在我的安装了LabVIEW Real-Time 8.5的控制器上,当我在MAX中对cRIO-901x展开Software tab时,遇到了一些错误信息。其中的一条错误信息指出了启动LabVIEW Runtime的错误,并且提示重装该产品并且联系National Instruments.当我从该控制器上安装/卸载软件时,另一条消息对话框提示该
URL:
http://digital.ni.com/public.nsf/allkb/119A978A104B95DC862573570044166F
Sort by:
Date (Most recent)
Title (A-Z)
1-10 of
72
Next