サードパーティ製タッチパネルデバイスに TPC サービスをインストールするとエラーが発生します
Winsows XP embedded を搭載しているサードパーティ製タッチパネルデバイスを LabVIEW から制御しようとしています。技術データベース「How Do I Configure the NI TPC Service on My Touch Panel Device? 」を参考にして NI TPC サービスをインストールしようとすると、 "Error 1920. Service 'NI TPC Service' (NITPCService) falied to start. Verify that you have sufficient privileges to start
URL: http://digital.ni.com/public.nsf/allkb/ECB9504DC7A9CB3E862575E8001B4483
|
Extra Pulse Generated By NI PCIe-8255R When Using Close FPGA VI Reference
I am generating a pulse train from my NI PCIe-8255R. When I close the FPGA reference to my device it generates an unexpected extra pulse. Why is this happening, and how do I prevent it?
URL: http://digital.ni.com/public.nsf/allkb/180C2A1C1112BA2C862575E1006D6B6E
|
NI 9870 Does not show up in FPGA IO Constant
I have placed an I/O constant or I/O control as the input to my FPGA I/O Method Node or FPGA I/O Property Node and want to select my 9870/9871 module or one of it's ports. Why does it not show up as one of the selections?
URL: http://digital.ni.com/public.nsf/allkb/9BF90AF3B60A5458862575DE00541F3F
|
CompactRIO Controller Installation Issue: Connected - Safe Mode (Improper Installation)
I have just received my compactRIO controller and after installing LabVIEW RT software, the controller boots into SafeMode with the status of Connected - Safe Mode (Improper Installation). How do I get my CompactRIO controller out of this state?
URL: http://digital.ni.com/public.nsf/allkb/B2BA1B006C12B1A2862575D60044E192
|
How Does PID VI Handles Saturation Conditions?
How can I prevent actuator saturation and/or long saturation recovery on my control applications?
URL: http://digital.ni.com/public.nsf/allkb/08BA90F4749DF0C5862575D60067B9D2
|
How Do I Configure A Luminary Micro Stellaris ARM Target?
I wish to use the LabVIEW Embedded Module For ARM to target a Luminary Micro Stellaris chip other than the evaluation board. How do I configure my target?
URL: http://digital.ni.com/public.nsf/allkb/5E4FE2C9F0E061EF862575D30051131E
|
FPGA Compile Error: Cannot find input file 'toplevel_gen_map.ncd'
Why do I get the following error when I try to compile my FPGA code: FPGA Compile Error: Cannot find input file "toplevel_gen_map.ncd"? The compile time also takes an unusually long time.
URL: http://digital.ni.com/public.nsf/allkb/3C711A7642AD9F0D862575D10050FA61
|
Can I Set Advanced Password Options in the LabVIEW DSC Module?
I am setting up user accounts in the LabVIEW Datalogging and Supervisory Control (DSC) Module, and I would like to set some advanced password settings such as length requirements, complexity requirements, and password expiration. Is this possible?
URL: http://digital.ni.com/public.nsf/allkb/D023B94CF50415A0862575CA00598F90
|
Recuperando un Valor Numérico para la Frecuencia de Muestreo de un Módulo DSA en LVFPGA
Utilizando un Nodo de Porpiedad de E/S (I/O), puedo obtener el control enumerado (enum) de los datos de la frecuencia de muestreo de un módulo de Adquisición Dinámica de Señal (DSA). Sin embargo, este enum no provee un valor numérico para la frecuencia de muestreo (50k), entrega un valor para el
URL: http://digital.ni.com/public.nsf/allkb/7ED1F0511BC5079A862575DA005AEA47
|
Retreiving a Numeric Value for a DSA Module's Sampling Rate in LVFPGA
Using a IO Property Node, I can retrieve the data rate enum from a Dynamic Signal Acquisition module. However, this enum does not provide a numeric value for the sampling rate (50k), but rather a value for the enum (2).I want to get the numeric value for the sampling rate programatically so I can
URL: http://digital.ni.com/public.nsf/allkb/E9C03C26A0BB314F862575C80066EB92
|