Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
KnowledgeBase

Category(s) Selected [start over]

Software
: LabWindows/CVI Development Systems [remove] ,
Hardware
: Multifunction DAQ (MIO) [remove] ,
1-10 of 15
KnowledgeBase [see results below]. To refine your results, select another category.
Software
Base Package (2)
Full Development System (9)
Hardware
M Series (2)
E Series (3)
S Series (1)
Basic (1)
Portable (1)
Question Type
Bug Fix/ Error Message/ Error Code (1)
FAQ (1)
Install/Config (3)
Programming (7)
Specifications/ Documentation (1)
Unexpected Behavior/ Bad Reading (2)
Document Languages
English (11)
Spanish (1)
Japanese (2)
Korean (1)

Sort by:
1-10 of 15
Acquiring On-Board Temperature from a PCI-6704 Static Analog Output Module How can I read the on-board temperature sensor of a PCI-6704 data acquisition (DAQ) device?The text below appears in the user manual, but it does not explain how to actually acquire the device temperature? The onboard temperature sensor measures the air temperature URL: http://digital.ni.com/public.nsf/allkb/B04ECBEA61188801862573E7006DD98B
LabWindows/CVI で作成したDLL をTestStand からコールする方法 LabWindows/CVI で作成したDLL をTestStand からコールさせたいのですが、簡単なサンプルや手順書などはありませんでしょうか。 URL: http://digital.ni.com/public.nsf/allkb/2AFD55BB62C6266E86257273002B6BE0
How do I Specify my PFI Line as an External Clock Using Traditional NI-DAQ (Legacy) in LabWindows/CVI? I am using LabWindows/CVI to specify an external clock on a PFI line using Traditonal NI-DAQ. In LabVIEW I can use the AI Clock Config to specify a PFI line as an external clock but how do I achieve this in LabWindows/CVI? URL: http://digital.ni.com/public.nsf/allkb/6A93C0BC4122DE10862572680007E5D1
Why do USB M-Series Devices Acquire No Data Values on the First Read? I am performing continuous data acquisition using a USB M-Series device and have the DAQmxRead function parameter for the number of samples per channel set to -1. Why does the first call to the DAQmxRead function return zero data points? URL: http://digital.ni.com/public.nsf/allkb/BFBC9983653C184186257227007A1527
¿Cómo Puedo Darle Control sobre los Productos de National Instruments Instalados en mi Computadora a Usuarios que no son Administradores? ¿Cómo puedo autorizar a personas que comiencen la sesión como usuarios regulares, a tener los privilegios administrativos sobre software y hardware de National Instruments sin tener que darles permisos administrativos sobre todo lo demás? URL: http://digital.ni.com/public.nsf/allkb/376789BA8CC367D9862570A60051D528
After Restarting My SCXI Chassis My SCXI-1102 Returns Erroneous Data in LabWindows/CVI When LabWindows/CVI is open and I restart my SCXI chassis I receive erroneous data from my SCXI modules – including the SCXI-1102 thermocouple module. My SCXI is connected to my computer through an M-Series Data Acquisition card. How can I fix this problem? URL: http://digital.ni.com/public.nsf/allkb/F6B4FF12D9C2D1278625709A006D9E49
LabWindows/CVI에서 SCXI 섀시를 다시 시작한후 SCXI-1102 가 잘못된 데이터를 출력합니다. LabWindows/CVI를 열고 SCXI 섀시를 다시 시작하면 SCXI로 부터 잘못된 데이터를 받게됩니다 - SCXI-1102 Thermocouple 모듈을 포함. SCXI는 M시리즈 DAQ카드를 통해 컴퓨터에 연결되어 있습니다. URL: http://digital.ni.com/public.nsf/allkb/719309B3135785FE862570A500186D5E
When Should I Use Continuous or Finite Sampling Modes? When should one use Continuous, or N samples, or one of the other types of sampling, and what do they mean? URL: http://digital.ni.com/public.nsf/allkb/B86AA2D2FDE9A16086256FFC00604202
Why Do I Get Error 200452 When I Use Certain DAQmx Properties With My DAQ Board? I am trying to configure different properties using different DAQmx property nodes, and I am getting error 200452 with a possible reason being “Specified property is not supported by the device or is not applicable to the task.” URL: http://digital.ni.com/public.nsf/allkb/05A563FE3AA7B3C286256FF90077C303
When Does the New Data Get Outputted Using Continuous Buffered Output (S-Series 6115/6120)? I am using a PCI-6115/6120 S-Series board to do continuous waveform generation. I want to change the output waveform during the output operation. I am able to change the buffer data to generate different waveforms, but sometimes the output has to generate a whole cycle of the old data before the URL: http://digital.ni.com/public.nsf/allkb/53B5101B1FBF017886256F3200748793
Sort by:
1-10 of 15