Is It Possible to Use Both IVI and VISA In the Same Session? I have an instrument driver that uses IVI to open and close sessions. I am trying to use VISA Reads and Writes to communicate with the device. LabVIEW is not showing any broken wires and I can run the VI, but the instrument does not respond. URL: http://digital.ni.com/public.nsf/allkb/7D07EBEA638AE4008625721A0056A72F
Time-Out Error with the Agesa Instrument Driver Example I am using an instrument driver for my Agilent E4440A Spectrum Analyzer. When I run an Agesa example program, I receive timeout error -1073807339 occurring at the agesa Initialize With Options.vi. Why won't the example program work with the spectrum analyzer? URL: http://digital.ni.com/public.nsf/allkb/2208965FB36F63C3862570E700575074
Time-Out Error with the Agesa Instrument Driver Example I am using an instrument driver for my Agilent E4440A Spectrum Analyzer. When I run an Agesa example program, I receive timeout error -1073807339 occurring at the agesa Initialize With Options.vi. Why won't the example program work with the spectrum analyzer? URL: http://digital.ni.com/public.nsf/allkb/B52C73103C1761FD862570DC006BE147
IVI Error BFFA0016: 'Attribute Already Has a Value Waiting to be Updated.' While using an IVI driver, I sometimes get the IVI error message "Attribute already has a value waiting to be updated." (Error number BFFA0016) . This error occurs intermittently. What exactly does this mean and what can I do to the instrument driver or in the code that communicates with the URL: http://digital.ni.com/public.nsf/allkb/BCB3F94F667EBBA186256A01006C6440
What Parameters in Measurement & Automation Explorer (MAX) Are Ignored When Using an IVI Specific Driver (i.e., not a class driver)? The IVI configuration utility in MAX ignores some fields when used with a specific instrument driver. Background:Users of specific instrument drivers can use the setting in MAX if they pass a logical name to the "resource name" parameter (in either LV or CVI). This allows users URL: http://digital.ni.com/public.nsf/allkb/862567530005F09C862567BB007EB3FD
How Does the IVI State Caching Attribute Model Handle Dependencies between Different Attributes? How does the IVI state caching attribute model handle dependencies between different attributes? URL: http://digital.ni.com/public.nsf/allkb/A68C2BDB09C095C6862565F6007A780F