NI-DAQmx 任务多通道间温度读数的不一致 我创建了一个 DAQmx 温度任务从多个热电欧通道上读取温度值。在热电欧建立窗口,我根据我的传感器类型设置热电欧类型,如下图所示:< URL: http://digital.ni.com/public.nsf/allkb/DB8CE3BDD79D0951862571990022D7F9
Inaccurate Read from Voltage Generated by SCXI-1581 I am using a SCXI-1581 to generate a current output. To verify it is working correctly, I placed a resistor across the EX0+ / EX0- terminals to read the voltage. The voltage I am reading across the resistor is incorrect. What am I doing wrong? URL: http://digital.ni.com/public.nsf/allkb/91AC42A8713831248625714900610803
Why Does My SCXI-1126 Module Read Incorrect Values in DAQmx, but not in Traditional NI-DAQ? I have an SCXI-1126 module with an SCXI-1327 connector block. When I read in values using Traditional NI-DAQ, everything works perfectly, but when I use DAQmx, all of the values I read are far outside the expected range. URL: http://digital.ni.com/public.nsf/allkb/0B0690003D849BCF8625710D005AB3A0
After Restarting My SCXI Chassis My SCXI-1102 Returns Erroneous Data in LabWindows/CVI When LabWindows/CVI is open and I restart my SCXI chassis I receive erroneous data from my SCXI modules – including the SCXI-1102 thermocouple module. My SCXI is connected to my computer through an M-Series Data Acquisition card. How can I fix this problem? URL: http://digital.ni.com/public.nsf/allkb/F6B4FF12D9C2D1278625709A006D9E49
LabWindows/CVI에서 SCXI 섀시를 다시 시작한후 SCXI-1102 가 잘못된 데이터를 출력합니다. LabWindows/CVI를 열고 SCXI 섀시를 다시 시작하면 SCXI로 부터 잘못된 데이터를 받게됩니다 - SCXI-1102 Thermocouple 모듈을 포함. SCXI는 M시리즈 DAQ카드를 통해 컴퓨터에 연결되어 있습니다. URL: http://digital.ni.com/public.nsf/allkb/719309B3135785FE862570A500186D5E
SCXI-1520 Hardware Offset Nulling Fails with 'out of range' Error I tried to use the offset nulling feature of my SCXI-1520, but it fails with an error that says the measurement is too far out of range. How else can I null my measurement offset? URL: http://digital.ni.com/public.nsf/allkb/30D6D29F67104C4E8625709A004BA510
SCXI Overvoltage Issues I get crosstalk or ghosting on the channels of my SCXI module when the inputs are railed at their maximum values. How could this be solved? URL: http://digital.ni.com/public.nsf/allkb/C9D0BD68E7CB7D6F862570760057F72D
SCXI-1520モジュールを使用してアナログ入力電圧を計測できますか。 SCXI-1520モジュールを使用してアナログ入力電圧を計測できますか。 URL: http://digital.ni.com/public.nsf/allkb/C3138397CDD653008625702D00808F20
¿Cómo Creo una Escala para el Módulo SCXI-1122? Estoy tratando de añadir una escala personalizada (custom scale) a un canal virtual (virtual channel) del módulo SCXI-1122. Cuando intento seleccionar las propiedades de mi canal virtual no tengo la opción de escoger un Scaling Formula. URL: http://digital.ni.com/public.nsf/allkb/FFB164C9B89F7BD786256FFE00545D81
SCXI Configuration on Remote RT System Never Updates My SCXI chassis configuration in the Measurement & Automation Explorer (MAX) never changes even if modules are shuffled or changed. Why can't I delete my SCXI chassis from my RT system in MAX? URL: http://digital.ni.com/public.nsf/allkb/043D88990AB8535C86256FE80053ADA6