Cart
|
Help
NI Home
>
Support
> KnowledgeBase
KnowledgeBase
Select your country
Category(s) Selected
[
start over
]
Question Type
: Unexpected Behavior/ Bad Reading [
remove
] ,
Hardware
: SCXI [
remove
] ,
1-10 of
68
KnowledgeBase [
see results below
]. To refine your results, select another category.
Software
Calibration Executive
(1)
Driver Software
(9)
LabVIEW Modules
(1)
LabWindows/CVI Development Systems
(2)
Utility Software
(2)
Hardware
Chassis
(9)
Modules
(36)
Terminal Blocks
(14)
Document Languages
English
(44)
Spanish
(3)
Japanese
(6)
Chinese (Simplified)
(7)
Chinese (Traditional)
(2)
Korean
(6)
Search KnowledgeBase Documents:
Sort by:
Date (Most recent)
Title (A-Z)
1-10 of
68
Next
LFH200 Bare Wire Cables with Date Codes 3707 and 5007 Have Incorrect Pinouts
On the LFH200 Bare Wire cable, Leg J2, Leg J3, Leg J6 and Leg J7 have mismatched wire color codes when compared with the pin assignment table given in the LFH200 Cable Installation Instructions. This
URL:
http://digital.ni.com/public.nsf/allkb/F6C3FFFAC2A65970862573E7007F822E
How Can I Test a Device that Requires Excitation in MAX?
I am testing my SCXI device using test panels in Measurement & Automation Explorer (MAX) but the values aren't what I'm expecting. Is something wrong with my device?
URL:
http://digital.ni.com/public.nsf/allkb/C2553DEE2E3CF1BE862573A30062C1F3
Programmatically Obtaining Serial Number from SCXI-1127 and SCXI-1128 Modules
I am using the DAQmx Device » DevSerialNum property node in LabVIEW, and returning a value of '0' for the SCXI-1127 and SCXI-1128 devices in my system. All of my other SCXI modules return proper serial numbers. Why do I recieve a '0' instead of a serial number for these two modules?
URL:
http://digital.ni.com/public.nsf/allkb/8B1C5C1F5EEF15AA862572C700574A50
在PXI/SCXI混和机箱中不能通过SCXI背板访问模拟输出通道
我正在用一个PXI-1050混合机箱,在这个PXI系统的最右边槽位上有一块MIO板卡。我想用SCXI-1180通过SCXI背板访问这块MIO板卡上的模拟输出通道,但是在这些信号输出端我得不到任何值。
URL:
http://digital.ni.com/public.nsf/allkb/00D9387748E09B2F862572C400321042
MAX에서 시뮬레이션이 지원되지 않는 DAQ 디바이스
NI-DAQmx가 지원되는 디바이스를 가지고 있고, NI-DAQmx를 설치했습니다. MAX에서 해당 디바이스를 시뮬레이션하려고 하는데 설정 tree에서 내 시스템>>디바이스와 인터페이스>>NI-DAQmx디바이스에서 마우스 우클릭하여 새 NI-DAQmx디바이스
URL:
http://digital.ni.com/public.nsf/allkb/7043425C266978A1862572E6000FEF8C
Why Can't I Simulate my DAQ Device in Measurement & Automation Explorer?
My device is supported in NI-DAQmx and I have NI-DAQmx installed. I would like to simulate my National Instruments DAQ device in Measurement & Automation Explorer (MAX). When I navigate in the MAX Configuration tree to My System » Data Neighborhood » Devices and
URL:
http://digital.ni.com/public.nsf/allkb/4B20AD64F650D2D5862572C2005779A7
¿Por qué no Puedo Simular mi Dispositivo en Measurement & Automation Explorer?
Mi dispositivo si es soportado por NI-DAQmx y lo tengo instalado en mi computadora. Quiero simular mi dispositivo en Measurement & Automation Explorer (MAX). Cuando voy a voy a My System » Data Neighborhood » Devices and Interfaces y doy clic derecho en NI-DAQmx Devices y selecciono Create New
URL:
http://digital.ni.com/public.nsf/allkb/E6B55E10990A5E3A862572C6006934EE
Cannot Access Signals such as Analog Output Through SCXI Backplane Communication in a PXI/SCXI Combination Chassis
I am using a PXI-1050 combination chassis with a supported MIO card in the right-most slot of the PXI system. I am trying to access the analog output signals from the MIO board by using an SCXI-1180 to read the signals through the SCXI backplane, but I am unable to get any readings from
URL:
http://digital.ni.com/public.nsf/allkb/2E4B88FDAD56DDD3492572AC0078E845
电压信号合并在一起
NI Home This Document is not yet Rated Rate this Document 电压信号合并在一起 硬件: SCXI>>Modules>>SCXI-1100, SCXI>>Modules>>SCXI-1100 问题: 为什么在使用 SCXI-1100 时,我的电压信号合并在一起了? 解答: 信号合并在一起的原因是由于模块上的滤波器设置得太高了。滤波器设置可以通过模块上的跳线修改。请参考下列步骤 如果模块仍然在机箱中,关闭机箱并移除模块。 移除模块的盖板。 从 W4 中移除跳线 (4 Hz 滤波器) 并连接到 W3 (10 kHz 滤波器) 或者 W2
URL:
http://digital.ni.com/public.nsf/allkb/93455DF1C82D4DDC4825721F00076CA8
SCXI Quick Start Guide Reference
I am looking for cable assemblies, terminal blocks and other accessories for my SCXI system. Where can I find this information?
URL:
http://digital.ni.com/public.nsf/allkb/8293C97CAC86374886257212005F159C