How Can I Test a Device that Requires Excitation in MAX?
I am testing my SCXI device using test panels in Measurement & Automation Explorer (MAX) but the values aren't what I'm expecting. Is something wrong with my device?
URL:
http://digital.ni.com/public.nsf/allkb/C2553DEE2E3CF1BE862573A30062C1F3
Inconsistent Temperature Readings Between Multiple Channels In NI-DAQmx Tasks
I created a DAQmx Temperature task to take readings from multiple thermocouple channels. On the Thermocouple Setup screen, I set the Thermocouple Type according to my sensor, as seen in the following image:
URL:
http://digital.ni.com/public.nsf/allkb/D40CC052881A5B708625715600720C22
NI-DAQmx 任务多通道间温度读数的不一致
我创建了一个 DAQmx 温度任务从多个热电欧通道上读取温度值。在热电欧建立窗口,我根据我的传感器类型设置热电欧类型,如下图所示:<
URL:
http://digital.ni.com/public.nsf/allkb/DB8CE3BDD79D0951862571990022D7F9
SCC-CTR01 모듈은 색띠는 문서에 나타나 있는 노랑색 대신에 파란색으로 되어 있는데 왜그런겁니까?
SCC-CTR01 모듈은 SCC캐리어의 아날로그 입력 슬롯에 설치해야된다는 의미인 파란띠를 가지고 있습니다. 그러나 문서에는 카운터 슬롯에 설치해야되는 모듈은 노란색이라고 나와있습니다. 왜 이렇게 되어 있습니까?
URL:
http://digital.ni.com/public.nsf/allkb/D42F70DD0410600186257089000F4BFD
Why is the Stripe on my SCC-CTR01 Module Blue Instead of Yellow as the Documentation Indicates it Should Be?
My SCC-CTR01 module has a blue stripe on the label which seems to indicate it is compatible with analog input slots in my SCC carrier. The documentation indicates that this stripe should actually be yellow to indicate its true compatibility with counter slots. Why is this?
URL:
http://digital.ni.com/public.nsf/allkb/3F7F820F0DC7B4A486257082008218BC
I Am Not Getting Any Frequency Readings When Using the SCC-FV01.
I am trying to use the SCC-FV01 to measure a frequency signal that goes anywhere from 0 to 10 Volts. When I test it in MAX, it doesn't seem to be working.
URL:
http://digital.ni.com/public.nsf/allkb/D52F25097F164E4C86256FCD006027C9
Why Am I Getting Noisy Measurements with My SC-2345 Signal Conditioning Modules?
I have an SC-2345 box with one or more signal conditioning modules. I am able to read from the modules, but I get inconsistent or noisy readings. Shouldn't the signal conditioning take care of the noise for me?
URL:
http://digital.ni.com/public.nsf/allkb/4F00A0167643CC2F86256F39004EDD06
What Does the Analog and Digital Power Requirement for SCC Modules Mean?
The specifications for the SCC Signal Conditioning modules give a power requirement specification for Analog and Digital. What does this mean and how are these values used to calculate the total power required per carrier?
URL:
http://digital.ni.com/public.nsf/allkb/6C5F21F122D61C9586256E29006B62F1
Using SCC-DO01 to Output Digital Voltages
I am trying to use the SCC-DO01 module to output digital voltages. When I change the state of the digital line the SCC-DO01 module is connected to, I do not see any voltage change on the output of the SCC-DO01. Can I use the SCC-DO01 module to output a digital voltage without an external supply?
URL:
http://digital.ni.com/public.nsf/allkb/97FF5CAA67B6075186256DDC00053ECD
Are All the SC-2345 Ground Lines Connected?
I have an SCC-FT01 plugged into an SC-2345, and I am seeing a slight offset on my readings. I think it may be caused by grounding issues. Are all the grounds on a SC-2345 connected?
URL:
http://digital.ni.com/public.nsf/allkb/4804BB9C978629B986256DCC0065C7C8
Sort by:
Date (Most recent)
Title (A-Z)
1-10 of
12
Next
Search KnowledgeBase Documents: