Cart
|
Help
NI Home
>
Support
> KnowledgeBase
KnowledgeBase
Select your country
Category(s) Selected
[
start over
]
Question Type
: Unexpected Behavior/ Bad Reading [
remove
] ,
Hardware
: CompactRIO [
remove
] ,
21-30 of
31
KnowledgeBase [
see results below
]. To refine your results, select another category.
Software
LabVIEW Modules
(6)
Driver Software
(14)
LabVIEW Toolkits
(1)
LabWindows/CVI Add-ons
(1)
Utility Software
(2)
Hardware
Chassis (Backplanes)
(1)
Controllers
(15)
Analog Input Modules
(12)
Digital Input Modules
(4)
Digital Output Modules
(3)
Document Languages
English
(14)
Spanish
(1)
Japanese
(2)
Chinese (Simplified)
(6)
Chinese (Traditional)
(4)
Korean
(4)
Search KnowledgeBase Documents:
Sort by:
Date (Most recent)
Title (A-Z)
21-30 of
31
Previous
|
Next
Noisy DC Power Can Cause Unpredictable CompactRIO Operation
My CompactRIO System is behaving in an unexpected manner. Sometimes it reboots randomly or even fails to boot at all. It is powered off a vehicle's power supply. What is happening?
URL:
http://digital.ni.com/public.nsf/allkb/75B55124050702C68625718E0049013D
노이즈한 DC전원이 예측할수 없는 CompactRIO의 동작들을 발생시킵니다.
CompactRIO 시스템이 이상하게 동작합니다. 때때로 불규칙하게 재부팅되거나 또는 전혀 부팅되지 않기도 합니다. 그래서 장비의 전원 공급이 차단됩니다. 무엇이 문제입니까?
URL:
http://digital.ni.com/public.nsf/allkb/E890496BA2CE39C386257211001CD376
为什么我最新的cRIO模块不能被LabVIEW FPGA 1.1检测到?
我正在使用LabVIEW FPGA 1.1,同时我添加了最新的cRIO模块(NI 9203、9205等等,参看下面的链接)。当我进入'Embedded Project Manager'为CompactRIO配置目标并点击'Discover Modules'时,所有的老模块都能被发现,可是插有新模块的插槽却报告'Unknown'。我也尝试着在一个空槽中手动添
URL:
http://digital.ni.com/public.nsf/allkb/9BDF588E0EFF24D748257172003A9D2A
Why Are My Newer cRIO Modules Not Detected By LabVIEW FPGA 1.1?
I am using LabVIEW FPGA 1.1, and I have added one of the newer cRIO modules (NI 9203, 9205, etc. See list below) to my bank. When I go into the 'Embedded Project Manager' to Configure Target for CompactRIO and click 'Discover Modules', all of my older modules are found, but the slot that holds the
URL:
http://digital.ni.com/public.nsf/allkb/E98B9ADFB3AF05BC86257147004A2709
なぜ新しいcRIOのモジュールはLabVIEW FPGA 1.1で認識されないのですか?
LabVIEW FPGA 1.1を使用して、新しいcRIOモジュール(NI 9203, 9205, 下記リスト参照)を追加しました。Embedded Project ManagerからCompactRIOの構成を行うために'Discover Modules'をクリックすると、以前購入したモジュールは表示されるものの、新しいモジュールがインストール
URL:
http://digital.ni.com/public.nsf/allkb/C0DAC6232E31F92E8625716F00391106
Temperature Readings With NI-9211 Are Off By Some Degrees
When using the NI-9211 temperature module, I can see that there is a couple of degrees error at very high or very low temperatures. Why is this?
URL:
http://digital.ni.com/public.nsf/allkb/AAEC7BF96A019EFB862570E4006D9204
在某些溫度下用NI-9211讀取會有誤差
當使用NI-9211溫度模組時,我發現在非常高或非常低的溫度下會產生一些偏差,為什麼會這樣呢?
URL:
http://digital.ni.com/public.nsf/allkb/474077DD3B3F7E768625735B0041C466
cRIO-9411 の動作モードを差動かシングルエンドに設定する方法
cRIO-9411 の動作モードを差動かシングルエンドに設定するには、どうすればよいのでしょうか
URL:
http://digital.ni.com/public.nsf/allkb/EC65B2453CB3EAE7862570D5000AFC2C
DAQmx Base程式不能做成執行檔
我有一個DAQmx-Base程式是用到USB-9161搭配cRIO-9215。程式在LV下面執行一切正常也傳回預期的值,但當我把它做成執行檔程式就不能動了。它只會傳回ERROR而不會有任何值傳出。到底是什麼問題呢?
URL:
http://digital.ni.com/public.nsf/allkb/630CDFBD7912929586256FC60008ADE0
DAQmx Base로 짠 프로그램이 EXE로 만들면 동작하지 않습니다.
USB-9161에 cRIO-9215를 연결하여 DAQmx-Base로 코딩하였습니다. 랩뷰상에서 프로그램을 실행하면 정상적으로 작동하지만, 이것을 EXE 파일로 만들어서 실행하면 동작하지 않습니다. 에러가 발생하지도 않지만 데이터도 내보내지 않습니다. 무엇이 잘못되었습니까?
URL:
http://digital.ni.com/public.nsf/allkb/1DBE9B277679599286256FD400331DFA
Sort by:
Date (Most recent)
Title (A-Z)
21-30 of
31
Previous
|
Next
Search KnowledgeBase Documents: