Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
KnowledgeBase

Category(s) Selected [start over]

Question Type
: Unexpected Behavior/ Bad Reading [remove] ,
Hardware
: Digital I/O (DIO) [remove] ,
11-20 of 40
KnowledgeBase [see results below]. To refine your results, select another category.
Software
Driver Software (5)
LabVIEW Development Systems (4)
Measurement Studio (1)
Utility Software (1)
Hardware
High-Speed (16)
Isolated (11)
Static (8)
Document Languages
English (22)
Spanish (1)
Japanese (5)
Chinese (Simplified) (6)
Chinese (Traditional) (1)
Korean (5)

Sort by:
11-20 of 40
|
The niHSDIO Session Initialiation VIs in NI-HSDIO 1.4 for LabVIEW 7.1 Do Not Populate the Resource Name Field I am using LabVIEW 7.1 or older and I have installed NI-HSDIO 1.4 (or newer). Why is the niHSDIO Init Acquisition/Generation Session Resource Name not automatically populating? URL: http://digital.ni.com/public.nsf/allkb/FAC51679500545738625705E006B7994
Digital Input/Output (DIO) Hardware Change from OKI 82C55 to Intersil 82C55 I have an NI product that formerly used the OKI 82C55 for the digital input/output (DIO) functionality such as the PCI-DIO-96, PCI-6503, PXI-6508, or the DAQCard-DIO-24. My current product revision uses the Intersil 82C55 instead of the OKI. I have noticed some differences in my application, URL: http://digital.ni.com/public.nsf/allkb/71FF33A835A0ED2D862573E9004BEA44
Intersil 82C55 Differences from OKI 82C55 I have an NI product that formerly used the OKI 82C55 for the digital input/output (DIO) functionality. My current product revision uses the Intersil 82C55 instead of the OKI. I have noticed some differences in my application, and saw the notification of specifications change document included in URL: http://digital.ni.com/public.nsf/allkb/5EB377C6A0C5C83F86256FBE00730E62
沖電気製82C55とインターシル社製82C55の相違点 以前はOKI(沖電機工業)製の82C55デジタルI/Oチップが搭載されていたNI製ボードを使用しています。現在のリビジョンの製品は,沖電気の代わりにインターシルの82C55が搭載されています。両者では若干動作が異なっており,またパッケージにはSpecification Changes URL: http://digital.ni.com/public.nsf/allkb/19EC02404D36090C86256FEA00211191
Error -1074118655, -1073807343 o -1074118644 Ocurre Cuando se Direcciona a un Instrumento PXI Cuando trato de abrir una sesión para mi Instrumento PXI (NI-DMM, NI-FGEN, NI-SCOPE, NI-HSDIO, NI-SWITCH) o intento validar mi dispositivo virtual en NI Switch Executive, obtengo uno de los siguientes errores. ¿Qué significa esto? URL: http://digital.ni.com/public.nsf/allkb/4FA13293B85321868625741E00760C80
Error -1074118655, -1073807343 or -1074118644 Occurs When Addressing a PXI Instrument When I try to open a session to my PXI instrument (NI-DMM, NI-FGEN, NI-SCOPE, NI-HSDIO, NI-SWITCH) or try to Validate my Virtual Device in NI Switch Executive, I get one of the following errors. Why is this? URL: http://digital.ni.com/public.nsf/allkb/8130049893D6461E86256F3B00461E1B
PXIデバイスのアドレス設定で、Error -1074118655、 -1073807343、 -1074118644が発生するときの回避方法 PXIモジュール型計測器[NI-DMM, NI-FGEN, NI-SCOPE, NI-HSDIO, NI-SWITCH]とセッションを開こうとすると、エラー[-1074118655、 -1073807343、 -1074118644]になってしまいます。これはなぜですか? URL: http://digital.ni.com/public.nsf/allkb/033CC9D6A549D15586256FE400042E7A
When I Connect DPULL to +5V on my DIO Board, the Data Lines Never Go Low When the DPULL line is not used, everything works as expected. When I connect the DPULL input to +5V, the data lines never go low. Why is this? URL: http://digital.ni.com/public.nsf/allkb/2FAE78FE22CA3D4A86256F3400723115
Why Am I Reading Negative Values From My Digital I/O Board? When using Visual Basic or C functions to read from my digital I/O board, (e.g., PCI-653x), the returned value is negative. How is this possible? URL: http://digital.ni.com/public.nsf/allkb/11962F97C36675BB86256F34006E36A0
Problem Controlling Relays with Digital Lines Why am I having a problem controlling relays using the digital lines from my DAQ board? Sometimes the relays work and sometimes they don't. URL: http://digital.ni.com/public.nsf/allkb/89FB08919072A35686256F2600091E45
Sort by:
11-20 of 40
|