Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
KnowledgeBase

Category(s) Selected [start over]

Question Type
: Unexpected Behavior/ Bad Reading [remove] ,
Hardware
: Modular Instruments [remove] ,
1-10 of 45
KnowledgeBase [see results below]. To refine your results, select another category.
Software
Driver Software (7)
LabVIEW Development Systems (2)
Hardware
Digital Multimeters (DMM) (6)
Dynamic Signal Acquisition and Analysis (DSA) (14)
High-Speed Digitizers (Scopes) (13)
High-Precision DAQ (Dataloggers) (3)
RF Measurement Devices (9)
Power Supplies (3)
Document Languages
English (21)
Spanish (2)
Japanese (3)
Chinese (Simplified) (8)
Chinese (Traditional) (3)
Korean (8)

Sort by:
1-10 of 45
PXI-4110 Power Supply를 이용한 Bipolar Voltage Source 이용이 불가능한 이유 PXI-4110 DC Power Supply를 가지고 있고, 그것의 ch0, ch1을 이용하여 bipolar voltage source로 사용하려고합니다. 제가 DMM을 이용하여 전압을 측정하면 잘 돌아가는 것처럼 보이지만, 실제 load를 연결하면 전압의 변화가 예측하기 어려운 식으로 돌아갑니다. 무슨 일이 일어■> URL: http://digital.ni.com/public.nsf/allkb/E3B66BB6675B4054862572D6002F9C5A
Using the PXI-4110 Power Supply to Create a Bipolar Voltage Source I have a PXI-4110 DC Power Supply and I'd like to configure it to be used in a bipolar setup with channels 0 and 1. When I attach a DMM to measure the differential voltage it appears to work, but connecting a load causes the voltage level to change or drop unexpectedly. Why does this happen? URL: http://digital.ni.com/public.nsf/allkb/E560A8859129402B862572C2000DBF0A
我能在不同速率下同步不同类型 DSA 设备么? 我有一块 4462 和 4472。我想要在不同的数据采集下同步这两块设备。是否可能? URL: http://digital.ni.com/public.nsf/allkb/CE9A32B4D9976FB04825723B0036525F
自校准和外部校准的区别是什么? NI Home This Document is not yet Rated Rate this Document 自校准和外部校准的区别是什么? 硬件: Modular Instruments, Multifunction DAQ (MIO) 问题: 自校准和外部校准的区别是什么? 解答: 校准是很重要的,因为任何一个特定的模数转换器的性能都会随着温度、输入电压、时间或其它因素的变化而变化。因此,当校准DMM或者DAQ板卡的时候,就需要考虑上述两种情况。 URL: http://digital.ni.com/public.nsf/allkb/BA55B76C85D4210A8625723900367377
Can I Synchronize Different Types of DSA Devices at Different Rates? I have a 4462 and a 4472. I would like these two devices to be synchronized together but to acquire data at different rates. Is this possible? URL: http://digital.ni.com/public.nsf/allkb/83C82B37411D837286257221006D5288
DSA 장비의 다른 타입의 보드를 다른 Rate에서 동기화할 수 있습니까? 4462 와 4472 보드를 가지고 있습니다. 두개의 보드를 함께 동기화하여 다른 Rate로 데이터를 수집하고 싶습니다. 이것이 가능합니까? URL: http://digital.ni.com/public.nsf/allkb/5F4FEBDCD76C607D86257236000B5EDF
ni5660 Configure for IQ VI Sets Incorrect RF and IF Attenuation Values on NI PXI-5660 RF Signal Analyzer The version of the ni5660 VI titled 'ni5660 Configure for IQ' that is installed by NI-RFSA 2.0 sets incorrect attenuation on the NI PXI-5660 RF vector signal analyzer. This issue only occurs when using the LabVIEW ni5660 Configure for IQ VI to configure an IQ data acquisition on an NI URL: http://digital.ni.com/public.nsf/allkb/84D4932EE5942BCC8625720A0076E8DF
ni5660 Configure for IQ VI 为NI PXI-5660 RF信号分析仪设置了错误的RF和IF衰减值 安装了 NI-RFSA2.0 之后名为 'ni5660 Configure for IQ' 的VI为NI PXI-5660 RF矢量信号分析仪设置了错误的衰减值。这个问题只发生在使用 LabVIEW 的 ni5660 Configure for IQ 这个VI来配置 NI PXI-5660 的IQ数据采集的情况下,其中 NI PXI-5660 由 NI PXI-5600 下变频器和 NI URL: http://digital.ni.com/public.nsf/allkb/C0D3EDBDB21D8FF7862573630040A426
Decreasing the digits of resolution on my DMM causes incorrect readings when measuring coil resistance. I am measuring a coil resistance. When I set my DMM to measure at 6.5 digits of resolution my readings are all good. When I read at 5.5 Digits my readings are off by +/-5 Ohms. When I measure at 4.5 Digits my readings are off by about +/-10 Ohms. When I am measuring resistance in the 50 URL: http://digital.ni.com/public.nsf/allkb/D99D0C3EE1E6846086257206003C0E6F
Simple Troubleshooting Steps to Improve Scope Accuracy I am aware of the DC and AC accuracy specifications listed for my NI High-Speed Digitizer. However, my voltage measurements are not as accurate as I would like them to be. What can I do to fix this? URL: http://digital.ni.com/public.nsf/allkb/71D068C4B5D35D0C862572050005F756
Sort by:
1-10 of 45