Why do I have a Time Drift in my Synchronized DAQ-CAN Application?
If you are using the standard examples for synchronization between a DAQ and a CAN board, sometimes there are drifts between the signals, so it seems that the synchronization does not work correctly. This behavior is related to the DAQ timebase which is used as the master timebase for both
URL:
http://digital.ni.com/public.nsf/allkb/B846715D4A0586BE86257115005A4AA9
Easy Way to Test if My DAQCard 700 is Working Properly
I have a DAQCard 700, and I am not sure if it is working properly. What is an easy way to test it?
URL:
http://digital.ni.com/public.nsf/allkb/CF5D4B1F6C263A2C86256F7A00736B65
My Laptop is Reading a Floating Voltage from a Grounded Source in Differential Mode
I am reading a floating signal when measuring in differential mode on my laptop. When I plug in my network cable, the problem seems to go away, but plugging my laptop into the power outlet does not solve the problem. What can I do about this problem?
URL:
http://digital.ni.com/public.nsf/allkb/3C6360322410D7A786256E1D0070C375
Incorrect Analog Input Readings When Using a DAQCard Windows NT
I am using a DAQCard-500, 516, or 700 on Windows NT. The analog input readings differ significantly from the applied voltage. Also, when I open the Measurement & Automation Explorer (MAX), the Serial Number for the card shows up as '0'.
URL:
http://digital.ni.com/public.nsf/allkb/6B7BD73E3859C93386256B3A005BAB79
Why Does the Counter Source Sink 120mA When the Computer is Powered Off?
I have an E Series MIO device with a TTL signal connected to the counter's SOURCE input. When I switch off the computer, I measure a sink current of approximately 120mA on the source of the counter. When I disconnect the power cable to the PC, I do not have this problem. How can I limit this
URL:
http://digital.ni.com/public.nsf/allkb/ECEA7CDB32970E91862566120070C527
NI DAQCard-1200 Icon Does Not Appear on PowerBook 5300 Desktop
I am using a DAQCard-1200 in a PowerBook 5300, and the DAQCard icon does not appear on the desktop. However it does appear in the NI-DAQ Control Panel.
URL:
http://digital.ni.com/public.nsf/allkb/A89F0F964F11D0A28625655B006D47E7
Why Does My Floppy Drive Light Turn On when Reading from Channel 16?
I am running NI-DAQ 4.9.0 on a Windows 95 machine. When I read from Channel 16 on the AT-MIO-64E-3, the floppy drive light turns on. Reading from other AI channels does not cause this problem. Why is the light on when I access Channel 16?
URL:
http://digital.ni.com/public.nsf/allkb/EBB88256159E7C378625654C004ED706
AT-MIO-16DE-10 와 PCI/PXI-6025E 보드에서 어떤 DIO 포트를 사용할 수 있습니까?
AT-MIO-16DE-10 의 어느 포트를 통해서 읽기/쓰기를 할 수가 있습니까?
URL:
http://digital.ni.com/public.nsf/allkb/B2757B2DA95AD4A086256E7D00089DBB
After Power Cycling the DAQPad-1200 with LabVIEW Open, I Get Bad Data when I Run a VI
If I power cycle my DAQPad-1200 while LabVIEW is open, then I get bad data when I subsequently run my VI. I have to exit LabVIEW and re-run the configuration utility in order to reset the parallel port. Then I can reopen LabVIEW and get good data. How can I avoid this?
URL:
http://digital.ni.com/public.nsf/allkb/8970D8B2D739E74D862564AA0069FB0B
Dell Computer with E-Series Board Disables the Floppy Drive
I have an AT-MIO-16E-10 board with NI-DAQ 5.0 and Windows NT 4.0 on a Dell Pentium Pro 200 computer with latest BIOS. The PnP BIOS was giving away resources already assigned to the floppy controller, disabling the floppy (A:) drive.