Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
KnowledgeBase

Category(s) Selected [start over]

Question Type
: Unexpected Behavior/ Bad Reading [remove] ,
Hardware
: FieldPoint [remove] ,
11-20 of 41
KnowledgeBase [see results below]. To refine your results, select another category.
Software
LabVIEW Development Systems (2)
LabVIEW Modules (1)
Driver Software (1)
Hardware
Controllers/Network Modules (19)
Analog I/O Modules (6)
Discrete I/O Modules (2)
Dual-Channel Modules (2)
Terminal Bases (2)
Document Languages
English (28)
Spanish (3)
French (1)
Japanese (2)
Chinese (Simplified) (1)
Chinese (Traditional) (2)
Korean (4)

Sort by:
11-20 of 41
|
FP-1601 狀態燈間歇閃爍。 我的FP-1601 狀態燈會間歇閃爍。而且在MAX中看不到FP-1601,讓我無法設定。請問為什麼? URL: http://digital.ni.com/public.nsf/allkb/ED9CA647BF1B466E86256F12003792DD
Adding an Extra FieldPoint Module Causes Failure I have a FieldPoint system which works very well with an FP controller and two analog input (AI) modules on the terminal base. My controller is powered and I am able to acquire data from my modules successfully. I decided to add a 3rd module when I needed more channels and now that I have added it, URL: http://digital.ni.com/public.nsf/allkb/12FC571B9508445186256EDE0066677D
Why Can't I Communicate with My FP-1000? I have had several FP-1000 units that have repeatedly stopped working in the past. I have RMA'd these network modules in the past and received reports that two resistors (R44 and R45) inside the unit were fried. Why am I burning up these resistors? URL: http://digital.ni.com/public.nsf/allkb/4A8D0F0F0AF72E4D86256ED800596460
AI-110이 주어진 샘플링 속도만큼 빠르지 않은 이유는 무엇입니까? AI-110 메뉴얼에 따르면 필터가 500 Hz로 설정되어 있을때 약 5 Hz의 샘플링 속도를 낼 수 있다고 되어 있습니다. 하지만 이러한 속도를 얻지 못하고 있습니다. 무엇이 문제입니까? URL: http://digital.ni.com/public.nsf/allkb/9BF40F11BFA3115D86256E7F0007DFC6
Why is My AI-110 is Not Sampling as Fast as It Should? The AI-110 manual states that with the filter set to 500 Hz, I should see a sampling rate around 5 Hz, but I do not, what is wrong? URL: http://digital.ni.com/public.nsf/allkb/AC3801430397CEB886256E74005F98D3
¿Cómo Leer o Escribir a Múltiples Canales en un Módulo de FieldPoint Desde LabVIEW? Me gustaría poder leer o escribir a múltiples canales en un módulo de FieldPoint desde LabVIEW sin tener que utilizar distintas etiquetas o varias funciones de lectura/escritura. ¿Cómo puedo lograr esto? URL: http://digital.ni.com/public.nsf/allkb/369DE731AA7AC81B86256E710076334A
Does the FP-SG-140 Support Offset Nulling and Shunt Calibration? I would like to perform an offset null and shunt calibration operations on my strain gage sensor using the FP-SG-140 module. Is this possible? URL: http://digital.ni.com/public.nsf/allkb/2710BD3298CFBFC686256E5A006BF67C
What is the Maximum Length of a FieldPoint Bus Extension Cable? I want to use a FieldPoint bus extension cable. What is the maximum length, how many can I have, etc? URL: http://digital.ni.com/public.nsf/allkb/A5AF564A4567190A86256E54006A9E05
What is the Load Current of the FP-DI-DC Dual Channel Module? I have a FP-TB-10 and am using it with the FP-DI-DC dual channel module. The user manual for the FP-TB-10 lists the voltage range for this module and the minimum current levels. It does not, however, mention the module's load current. Where can I find this information? URL: http://digital.ni.com/public.nsf/allkb/6B7739B21F1C29EE86256E440055B827
What is the Difference Between the CB-37FV and the CB-37FH Connector Blocks? I know that there are two external DIN-Rail-Mounted connector blocks available for Compact FieldPoint, but what is the difference between the CB-37FV and the CB-37FH URL: http://digital.ni.com/public.nsf/allkb/71FFE29A074B058686256E34007C39D5
Sort by: