Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
KnowledgeBase

Category(s) Selected [start over]

Question Type
: Unexpected Behavior/ Bad Reading [remove] ,
Software
: Driver Software [remove] ,
21-30 of 311
KnowledgeBase [see results below]. To refine your results, select another category.
Software
FieldPoint Explorer (3)
NI ELVIS Driver VIs (8)
NI-435x (1)
NI-488.2 (28)
NI-CAN (4)
NI-DAQ (75)
NI-DAQmx (79)
NI-DAQmx Base (12)
NI-DMM (8)
NI-DNET (1)
More... 
Hardware
Multifunction DAQ (MIO) (29)
Compact FieldPoint (3)
CompactDAQ (8)
CompactRIO (13)
Counter/Timers (TIO) (1)
Digital I/O (DIO) (6)
FieldPoint (1)
GPIB (2)
Image Acquisition (IMAQ) (3)
Industrial Communications (1)
Instrument Connectivity Other (2)
Legacy DAQ Devices (1)
Modular Instruments (10)
More... 
Document Languages
English (188)
Spanish (11)
Japanese (33)
Chinese (Simplified) (23)
Chinese (Traditional) (24)
Korean (32)

Sort by:
21-30 of 311
|
Why is Incorrect Data Retuned When Communicating via Interactive Mode with NI-RIO 2.1.3 or Earlier? I Have and NI RIO application that performs array read/writes on a cRIO 901x controller that has NI RIO 2.3 and LabVIEW Real-Time 8.5 installed that returns incorrect data. When running in host interface mode, I get a LabVIEW Real-Time error about incompatible versions on the remote target URL: http://digital.ni.com/public.nsf/allkb/ACFAFB6C516C7C904825735300774D04
NI-Sync 3.0 Fails on Startup when Running RT I just installed NI Sync 3.0 and my startup application VI fails on my RT target. niSync Initialize returns 0xBFFF400A on startup URL: http://digital.ni.com/public.nsf/allkb/EF18A0733AE845188625734500567A57
Ghosting on Motion Controller Analog Inputs I have an NI-73xx Motion controller and I am using the analog input to read an analog signal. I have hooked up my signal to analog input channel 3, but in my program I am reading from analog input 1. Even though I am reading from a different channel than what I have connected, I still see URL: http://digital.ni.com/public.nsf/allkb/9CDFFA9DB8A876A48625733C0012796E
Why do I see Spurious Returns when using multiple Wait on IRQ Nodes on VxWorks Real Time Targets? NI-RIO 2.3 with LabVIEW 8.5 supports multiple Wait on IRQ nodes in a single VI, however, I see spurious returns from the "Wait on IRQ" Method Node when using cRIO-901x Controllers. This does not occur on my cRIO-900x Controllers or any other Pharlap based Real-Time controller. Why does this URL: http://digital.ni.com/public.nsf/allkb/A868BA261986A486482573380077794D
cFP-180x Firmware Upgrade Fails on the 10.0.54 Subnet The firmware upgrade fails when my cFP-180x is on the 10.0.54 subnet. It begins to upgrade and then terminates. How do I get around this? URL: http://digital.ni.com/public.nsf/allkb/6A9C6B3D1BE8DA5786257338007B9080
當我在VxWorks Real Time Targets環境下使用多個Wait on IRQ節點時,為何會得到假的回傳值? NI-RIO 2.3搭配LabVIEW 8.5的使用可以支援在單一VI中使用多個Wait on IRQ節點。然而,當我使用CRIO-901x控制器時,會從"Wait on IRQ" 節點得到假的回傳值。這個現象並不會發生在cRIO-9000x或其他Pharlap的Real-Time控制器。這個問題發生的緣由為何呢? URL: http://digital.ni.com/public.nsf/allkb/95BC4E473B7C6313862573AD00070404
Why Do I Get Error 50202? I am using NI software and I get error 50202. What is going on? URL: http://digital.ni.com/public.nsf/allkb/61060FCCEFD2D5EF86257337005B9ED7
NI-VISA 4.2 이상의 버전을 설치한 이후에 MAX에서 CompactRIO 컨트롤러가 보이지 않는 이유 최근에 NI-VISA를 업그레이드한 후, MAX에서 CompactRIO 컨트롤러가 보이지 않는 현상이 발생합니다. URL: http://digital.ni.com/public.nsf/allkb/6F612762E0CB18508625733A0003B808
Why Does My CompactRIO Controller Not Appear in MAX after Installing NI-VISA 4.2 or Later? I recently upgraded NI-VISA and can no longer see my CompactRIO controller(s) in MAX. What could be the problem and how can I fix this problem? URL: http://digital.ni.com/public.nsf/allkb/1C24D45C2850C5F6862573280013EDF8
为什么安装了NI-VISA 4.2及之后版本,我的CompactRIO控制器在MAX中看不到 最近我升级了NI-VISA然后在MAX中找不到CompactRIO控制器了,问题出在哪里如何解决? URL: http://digital.ni.com/public.nsf/allkb/42ECB8B0DC1ADCB7862573A3001339C0
Sort by:
21-30 of 311
|