Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
KnowledgeBase

Category(s) Selected [start over]

Question Type
: Unexpected Behavior/ Bad Reading [remove] ,
Software
: Driver Software [remove] ,
11-20 of 306
KnowledgeBase [see results below]. To refine your results, select another category.
Software
FieldPoint Explorer (3)
NI ELVIS Driver VIs (8)
NI-435x (1)
NI-488.2 (27)
NI-CAN (4)
NI-DAQ (75)
NI-DAQmx (77)
NI-DAQmx Base (12)
NI-DMM (7)
NI-DNET (1)
More... 
Hardware
Compact FieldPoint (3)
CompactDAQ (8)
CompactRIO (13)
Counter/Timers (TIO) (1)
Digital I/O (DIO) (6)
FieldPoint (1)
GPIB (2)
Image Acquisition (IMAQ) (3)
Industrial Communications (1)
Instrument Connectivity Other (2)
Legacy DAQ Devices (1)
Modular Instruments (8)
Motion Control (7)
More... 
Document Languages
English (184)
Spanish (11)
Japanese (33)
Chinese (Simplified) (23)
Chinese (Traditional) (23)
Korean (32)

Sort by:
11-20 of 306
|
1588 Synchronization Drifts Away with Time when using a 10 Mbps Router with the PXI-6682 I'm doing 1588 synchronization with the PXI-6682 but I've noticed that synchronization gets worse with time (the slave continues to drift away from the master). Looking at the "offset from master" property for the slave, the value will look normal (under 100ns) most of the time, but you'll URL: http://digital.ni.com/public.nsf/allkb/06F98C12AA16ACA68625737000629003
Special Considerations for PFI0 on the PXI-6682 PFI0 seems to behave inconsistently. Sometimes I get an immediate timestamp even if my input hasn't changed. The same problem happens if I connect PFI0 to a destination, the initial state seems to be floating. Do I have a problem with PFI0? URL: http://digital.ni.com/public.nsf/allkb/25CDB06E89A649B3862573700062BE1A
NI 9237真实的激励电压与指定电压值不同 在用NI 9237创建Strain或者Custom Voltage with Excitation的DAQmx任务时,在任务中指定的激励电压与我在Ex+和Ex-两端之间测到的电压不一致。例如,在创建任务时,我指定的激励电压为6V。然而,我在Ex+和Ex URL: http://digital.ni.com/public.nsf/allkb/3F7E5F74EE6458AB4825736F00208909
Noise When Using Video Display Driver and LabVIEW Real-Time 8.5 Why do I see random pixel noise on the op lines of the graphics display when I do a video out with LabVIEW Real-Time 8.5 and the video display driver? URL: http://digital.ni.com/public.nsf/allkb/A93CB039494377268625736A007AF517
'Wait Until' Trigger Produces Unexpected Signal The script pauses by generating the last 'n' samples when the script reaches a 'wait until' trigger. This is not an issue on the first 'wait until' trigger, but if a signal is generated when the 'wait' instruction occurs, some data is generated. URL: http://digital.ni.com/public.nsf/allkb/8783653E9EAB13A486257355005120C3
Why is Incorrect Data Retuned When Communicating via Interactive Mode with NI-RIO 2.1.3 or Earlier? I Have and NI RIO application that performs array read/writes on a cRIO 901x controller that has NI RIO 2.3 and LabVIEW Real-Time 8.5 installed that returns incorrect data. When running in host interface mode, I get a LabVIEW Real-Time error about incompatible versions on the remote target URL: http://digital.ni.com/public.nsf/allkb/ACFAFB6C516C7C904825735300774D04
NI-Sync 3.0 Fails on Startup when Running RT I just installed NI Sync 3.0 and my startup application VI fails on my RT target. niSync Initialize returns 0xBFFF400A on startup URL: http://digital.ni.com/public.nsf/allkb/EF18A0733AE845188625734500567A57
Ghosting on Motion Controller Analog Inputs I have an NI-73xx Motion controller and I am using the analog input to read an analog signal. I have hooked up my signal to analog input channel 3, but in my program I am reading from analog input 1. Even though I am reading from a different channel than what I have connected, I still see URL: http://digital.ni.com/public.nsf/allkb/9CDFFA9DB8A876A48625733C0012796E
Why do I see Spurious Returns when using multiple Wait on IRQ Nodes on VxWorks Real Time Targets? NI-RIO 2.3 with LabVIEW 8.5 supports multiple Wait on IRQ nodes in a single VI, however, I see spurious returns from the "Wait on IRQ" Method Node when using cRIO-901x Controllers. This does not occur on my cRIO-900x Controllers or any other Pharlap based Real-Time controller. Why does this URL: http://digital.ni.com/public.nsf/allkb/A868BA261986A486482573380077794D
cFP-180x Firmware Upgrade Fails on the 10.0.54 Subnet The firmware upgrade fails when my cFP-180x is on the 10.0.54 subnet. It begins to upgrade and then terminates. How do I get around this? URL: http://digital.ni.com/public.nsf/allkb/6A9C6B3D1BE8DA5786257338007B9080
Sort by:
11-20 of 306
|