1-10 of 373
How do I Determine the Sampling Rate for a SCXI 1520 Module. Problem: How do I determine the sampling rate for a SCXI 1520 module? Solution: SCXI 1520 is a simultaneous sampling device that uses track-and-hold technology. The maximum convert rate for simultaneous sample and hold (SSH) circuit in the SCXI 1520 is 10 us. URL: http://digital.ni.com/public.nsf/allkb/3E99FB68FDBD4ECB862573AF007DD7CE
为什么我的SCXI-1163在MAX中探测不到? 我有一个SCXI-1163在SCXI机箱中,但是当我在SCXI机箱配置对话框中点击Auto-Detect All Modules按钮时,MAX找不到SCXI-1163。 URL: http://digital.ni.com/public.nsf/allkb/646043A1CC9D701F4825739100233254
MAX에서 SCXI-1163이 보이지 않는 이유 SCXI-1163을 샤시에 삽입한 후, SCXI 샤시 설정 대화 창에서 Auto-Detect All Modules버튼을 클릭해도, MAX가 SCXI-1163을 인식하지 못합니다. URL: http://digital.ni.com/public.nsf/allkb/EB7A7DBDCCB2EA19862572BA002AD534
Why Isn't My SCXI-1163 Detected in MAX? I have a SCXI-1163 in my SCXI chassis, but when I click the Auto-Detect All Modules button in my SCXI Chassis Configuration dialog box, MAX does not find my SCXI-1163. URL: http://digital.ni.com/public.nsf/allkb/919B8C262E74A861862572B50049CF24
SCXI-1000 和 SCXI-1001 机箱的电源要求 SCXI-1000 和 SCXI-1001 机箱支持50或60 Hz的100, 120, 220, 或 240 伏交流电。当购买其中一种机箱时,您可以有7种电源选择,如下表所示。 电源选择: URL: http://digital.ni.com/public.nsf/allkb/170DAB478A642DE8482572A1001CD2F0
Where Can I Find The Warranty For My NI Hardware? I'm trying to find the warranty information for my NI hardware. Where can I find it? URL: http://digital.ni.com/public.nsf/allkb/8341879DC763DF5886257289005D816E
Tabla de Precisión de Termopares por Tipo y Temperatura Estoy leyendo la temperatura utilizando dos termopares del mismo tipo pero las lecturas son diferentes. He calculado la precisión de mi hardware de medida pero no compensa la diferencia en las lecturas. ¿Cuál puede ser la causa de este fenómeno? URL: http://digital.ni.com/public.nsf/allkb/79632A4CAD11B68086257410006D5746
Thermocouple Accuracy Table by Type and Temperature I am reading the temperature of a chamber using two thermocouple of the same type but the readings are different. I have calculated the accuracy of my measurement hardware but it does not compensate for the difference in readings. What may be causing this phenomenon? URL: http://digital.ni.com/public.nsf/allkb/776AB03E065228408625727B00034E20
Can I Use One SCXI Module in Multiple LabVIEW Applications at the Same Time? Can I use one SCXI module in multiple LabVIEW applications that will run simultaneously? Each application is specific to a certain test setup, but each test setup uses different channels on an SCXI card using one DAQ card. URL: http://digital.ni.com/public.nsf/allkb/55FDCBF1CA929B268625726E007EA229
NI Switches and AC Wall Power Compatability Which NI Switches can be used to switch AC wall power? I tried using the SCXI 1166 to switch wall power, but it didn't operate as expected. URL: http://digital.ni.com/public.nsf/allkb/855AF9CBDAACE3018625725A00638653