Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
KnowledgeBase

Category(s) Selected [start over]

Question Type
: Specifications/ Documentation [remove] ,
Hardware
: Signal Conditioning Other [remove] ,
11-20 of 59
KnowledgeBase [see results below]. To refine your results, select another category.
Hardware
SC Analog Accessories (20)
SC Digital Accessories (4)
SC Cable Adapters (3)
SSR Series (12)
5B Series (18)
6B Series (6)
Document Languages
English (46)
Spanish (2)
Japanese (2)
Chinese (Simplified) (5)
Chinese (Traditional) (1)
Korean (3)

Sort by:
11-20 of 59
|
Remote Sense Inputs on the SCXI-1520 and PXI-4220 I noticed two input terminals on my SCXI-1314 terminal block: RS+ and RS- What are these terminals and how do I use them? URL: http://digital.ni.com/public.nsf/allkb/724FDFA5FEA4FE9586256E9000762B64
Which Cables or Accessories Do I Need to Connect a DAQ Device to an SSR Backplane? There are several DAQ and DIO devices which can be connected to an SSR Backplane (Digital Signal Conditiong Backplane). Which devices are compatible, and which cables or accessories do I need to make the connection? URL: http://digital.ni.com/public.nsf/allkb/5325E710371BED4486256D4900463AC1
How Do I Access the Unused Pins of my DAQ Card when using SC-204x or AMUX? I am using a SC-2040 with my E-Series DAQ card but I still need to be able to use the analog output and counter functionality. URL: http://digital.ni.com/public.nsf/allkb/C73CEF550A561DE786256CE60065C7A2
SC-204x 또는 AMUX을 사용할 때 사용하지 않는 DAQ Card의 핀들을 어떻게 사용할 수 있습니까 ? E-Series DAQ card와 함께 SC-2040을 사용하고 있습니다. 그런데 아날로그 출력과 카운터의 기능을 사용하려면 어떻게 해야 합니까? URL: http://digital.ni.com/public.nsf/allkb/8721CE847C45E92B86256E68003B5077
Does National Instruments Support the 5B-02 Backplane for Use with its Data Acquisition (DAQ) Hardware? I have a 5B-02 backplane and 5B modules. Does National Instruments support using it with my DAQ system? URL: http://digital.ni.com/public.nsf/allkb/0CC9AB7049231BB8C1256C6400752276
What is the Difference Between the 5B-01 and 5B-02 Backplanes? What is the basic difference between the 5B-01 and 5B-02 backplanes and why does NI support one and not the other with NI DAQ boards? URL: http://digital.ni.com/public.nsf/allkb/B92F5ECB338569F986256C53006EF274
Why Are All My Analog Input Signals Reading Almost Zero Volts, But Not Floating? I have connected all of my analog inputs to my analog input 5B modules. I have cabled everything to my analog input board. When I take readings, they are not floating, but they are all stuck at approximately zero, though they may change slightly as the input voltage changes.What is wrong? URL: http://digital.ni.com/public.nsf/allkb/0959EF2F354A241186256C30005FDBE0
Determining the Channel Number of a 5B Module How do I determine the data acquisition (DAQ) channel number for each slot on my 5B backplane? URL: http://digital.ni.com/public.nsf/allkb/0F1872302CD4E9A486256BA3007692AA
How Do I Connect a BNC-2110 (or BNC-2120) to an E Series Device via an SC-2056? I would like to use a BNC-2110 (or BNC-2120) with a 100-pin E Series device that has 64 analog input (AI) channels. I have an SC-2056 connected to my device with an SH100100 cable. How do I connect a BNC-2110 or BNC-2120 to the SC-2056? URL: http://digital.ni.com/public.nsf/allkb/A3C2F96D5749513D86256AAF006E8B91
我怎样利用SC-2056连接BNC-2110(或BNC-2120)到一个E系列的设备 我想把BNC-2120(或BNC-2120)和100-pin的E系列设备一起使用,这个E系列设备有64个模拟输入(AI)通道。我用一个SH100100线缆连接SC-2056到我的设备。我怎么连接BNC2110或者BNC-2120到SC-2056? URL: http://digital.ni.com/public.nsf/allkb/D683ABA9E28A18258625738200316837
Sort by:
11-20 of 59
|