Cart
|
Help
NI Home
>
Support
> KnowledgeBase
KnowledgeBase
Select your country
Category(s) Selected
[
start over
]
Question Type
: Specifications/ Documentation [
remove
] ,
Hardware
: Multifunction DAQ (MIO) [
remove
] ,
21-30 of
956
KnowledgeBase [
see results below
]. To refine your results, select another category.
Software
LabVIEW Development Systems
(9)
LabVIEW Modules
(3)
LabWindows/CVI Development Systems
(2)
Driver Software
(46)
Measurement Studio
(8)
Hardware
Basic
(25)
Connector Blocks
(50)
E Series
(182)
M Series
(114)
Portable
(97)
Real-Time
(14)
S Series
(64)
SC Series
(3)
Document Languages
English
(526)
Spanish
(16)
French
(17)
Japanese
(109)
Chinese (Simplified)
(77)
Chinese (Traditional)
(83)
Korean
(128)
Search KnowledgeBase Documents:
Sort by:
Date (Most recent)
Title (A-Z)
21-30 of
956
Previous
|
Next
USB-621x Panel Mounting Template
To panel mount your USB-621x device, refer to the instructions in the NI USB-621x User Manual. Without scaling or resizing, print the attached PDF file that corresponds with your paper format and your USB device. Use the printout as your mounting template.
URL:
http://digital.ni.com/public.nsf/allkb/01382CF6D3D7C1B6862572CF00504BE4
Is the Sheilding for M-Series Cables Connected to Any Ground Pins on the Connector?
My project requirements are very specific about how the shielding of cables in our system has to work. Is the shielding on standard M-Series DAQ cables connected to any pins on the connector (such as Ground)?
URL:
http://digital.ni.com/public.nsf/allkb/BDC4F8E11194AE5B862572C000607317
Where Can I Find The Warranty For My NI Hardware?
I'm trying to find the warranty information for my NI hardware. Where can I find it?
URL:
http://digital.ni.com/public.nsf/allkb/8341879DC763DF5886257289005D816E
Why Does My DAQ Board Continue to Output a Voltage After I Close My Program?
I am running an analog output application which outputs a voltage to one or more channels on my DAQ board. After I stop the program, the card is still outputting the voltage. I need to make sure that my card does not continue to output a voltage after I stop my application. How can I do this
URL:
http://digital.ni.com/public.nsf/allkb/FA35E2F2B29A75638625727E0001F3F4
プログラムを停止しても、DAQボードは電圧を出力し続けますが、なぜでしょうか。
DAQボードの一つ以上のチャンネルからアナログ電圧を出力するようなプログラムを作成しています。プログラムを停止しても電圧は出力し続けます。PCを再起動せずに、プログラムの停止と同時に電圧の出力も止まるようにする方法なないでしょうか。
URL:
http://digital.ni.com/public.nsf/allkb/8944B976735E55488625738500389544
프로그램 종료후, DAQ Analog Output 전압이 유지되는 이유?
현재 한채널 혹은 여러채널의 아날로그 전압 출력을 수행하는 어플리케이션을 실행하고 있습니다. 그런데 프로그램을 종료한 후에도 프로그램 수행중 셋팅된 전압 레벨이 유지되고 있습니다. 저는 프로그램 종료된 후에는 전압 출력을 유지하고 싶지 않습니다
URL:
http://digital.ni.com/public.nsf/allkb/DA0C1DC9AE711087862572DF00084625
Is the PCI/PXI-6723 Compatible with the BNC-2115?
I have a PCI/PXI-6723 with two 68-pin connectors in the front. I see that Connector 0 can connect to a BNC-2110 becuase it has pins for digital, PFI, and counter lines, along with analog output channels 0 through 7. I see that Connector 1 has pins for analog output channels 8 through
URL:
http://digital.ni.com/public.nsf/allkb/9F83E6261786CFDB8625727B0020E13D
Tabla de Precisión de Termopares por Tipo y Temperatura
Estoy leyendo la temperatura utilizando dos termopares del mismo tipo pero las lecturas son diferentes. He calculado la precisión de mi hardware de medida pero no compensa la diferencia en las lecturas. ¿Cuál puede ser la causa de este fenómeno?
URL:
http://digital.ni.com/public.nsf/allkb/79632A4CAD11B68086257410006D5746
Thermocouple Accuracy Table by Type and Temperature
I am reading the temperature of a chamber using two thermocouple of the same type but the readings are different. I have calculated the accuracy of my measurement hardware but it does not compensate for the difference in readings. What may be causing this phenomenon?
URL:
http://digital.ni.com/public.nsf/allkb/776AB03E065228408625727B00034E20
用NI的DAQ设备测量大电流
我想知道如何测量一个电气发动机的效率。欲进行这种测量,我不仅需要测量发动机的电压,还得测量发动机的电流,有些发动机的电流会是位于4安培到200安培之间的任何值。NI是否具有类似的测量大电流的应用方案?
URL:
http://digital.ni.com/public.nsf/allkb/FDF51687B7CB58034825726700444542