Cart
|
Help
NI Home
>
Support
> KnowledgeBase
KnowledgeBase
Select your country
Category(s) Selected
[
start over
]
Question Type
: Specifications/ Documentation [
remove
] ,
Hardware
: Modular Instruments [
remove
] ,
1-10 of
208
KnowledgeBase [
see results below
]. To refine your results, select another category.
Hardware
Digital Multimeters (DMM)
(34)
Digital Transmission Analyzers
(3)
Dynamic Signal Acquisition and Analysis (DSA)
(82)
High-Speed Digitizers (Scopes)
(37)
High-Precision DAQ (Dataloggers)
(33)
RF Measurement Devices
(18)
Power Supplies
(5)
Document Languages
English
(121)
Spanish
(12)
Japanese
(8)
Chinese (Simplified)
(32)
Chinese (Traditional)
(8)
Korean
(27)
Search KnowledgeBase Documents:
Sort by:
Date (Most recent)
Title (A-Z)
1-10 of
208
Next
Maximum Record Length for National Instrument's Digitizers
Why do I get an error (-1074118653) when I try to specify a large number in the Record Length field?
URL:
http://digital.ni.com/public.nsf/allkb/285C5D42E6AF55C5862574040080EA7F
Different Types of Isolation: Channel-to-Channel, Bank (Channel-to-Bus), and Channel-to-Earth Ground Isolation
What are the differences between the types of electrical isolation NI offers on devices? I do not understand the differences between channel-to-channel, bank (channel-to-bus), and channel-to-earth ground isolation.
URL:
http://digital.ni.com/public.nsf/allkb/CF71091043A6193B862573D70077138B
Why Does the USB-4065 DMM Have 5 Input Terminals
I noticed that the USB-4065 DMM has 5 input terminals whereas other NI DMMs have 4. Why is this?
URL:
http://digital.ni.com/public.nsf/allkb/862F065BDE519865862573B7006C390F
¿Cuál es el la Resolución del Retraso (delay) del Disparo (trigger) en un NI 5112?
En la documentación del PXI-5112, encontramos que el retraso del disparo (trigger delay), se puede configurar entre 40 nano segundos y 171.85 segundos. ¿Cuál es entonces la resolución de esta demora de disparo?. Por ejemplo, podría yo especificar una demora de disparo de 41, 40.1 ó
URL:
http://digital.ni.com/public.nsf/allkb/4601345517DDD953862573AC006C1E23
¿Cual es la Relación entre Ancho de Banda y Tiempo de Subida?
Me gustaría digitalizar una onda cuadrada con tiempo de subida específico pero no estoy seguro cual es el ancho de banda recomendado y cuál sería el mejor digitalizador para esta tarea.
URL:
http://digital.ni.com/public.nsf/allkb/A45E6F72D167DC6A862573AA007B8598
动态信号采集(DSA)设备上的交流耦合能够移除多大的直流偏置?
我有一个具有很大直流偏置的信号,并想用DSA设备进行测量。交流耦合电路能够成功移除的直流偏置有限制吗?我的信号的幅值小于2.8V,而相对于板卡地的直流偏置超过12V。我还能够在交流耦合使能的情况下测量这个信号吗?
URL:
http://digital.ni.com/public.nsf/allkb/3CF5A29CC4F634E54825739100287DF2
NI 4498 Connector Diagram and Pinout
I'm having difficulty locating the NI 4498 connector diagram with the accompanying pinout. Where can I find this?
URL:
http://digital.ni.com/public.nsf/allkb/0E96DC4546D1D092862573830072B519
Getting a Negative Reading When Making a Resistance Measurement
I am using a DMM to measure a resistance. For the purpose of testing I had shorted all the input channels and made a resistance measurement using the DMM Soft Front Panel. I read a -12 mΩ. Why am did I get this measurement?
URL:
http://digital.ni.com/public.nsf/allkb/4996ED8931FD2BCE8625731D0000D875
USB-4065/5132/5133/6509 Panel Mounting Template
To panel mount your USB-4065/5132/5133/6509 device, refer to the instructions in the NI Digital Multimeters Getting Started Guide, NI High-Speed Digitizers Getting Started Guide, or the NI USB-6509 User Guide and Specifications. Without scaling or resizing, print
URL:
http://digital.ni.com/public.nsf/allkb/A6628FB3CEDA675A86257313005D60D5
What are the recommendations for using my PXIe-5122 below 10° C?
The PXIe-5122 specifications mention that there may be special considerations for operation in ambient temperatures between 0 and 10° C for maximum data transfer rates. What are these considerations?
URL:
http://digital.ni.com/public.nsf/allkb/964D3E2A838FC19B862572FB005DB1FB
Sort by:
Date (Most recent)
Title (A-Z)
1-10 of
208
Next
Search KnowledgeBase Documents: