1-10 of 17
RMIO and RDIO cables for R Series Intelligent DAQ R Series Intelligent DAQ devices have cable options that include both the SH68-C68-S cables and the SHC68-68-RMIO or SHC68-68-RDIO cables. URL: http://digital.ni.com/public.nsf/allkb/2873867ECCF3790B862573B40059ED2A
Why is my RIO Device Not Showing up in MAX under PXI System? When accessing an R-Series PXI board that is inside a remote chassis, why does the device not show up in MAX under PXI System items as thought? URL: http://digital.ni.com/public.nsf/allkb/A28BFE561FBB81C186257394005ACC27
Letter of Volatility for R Series Devices I need official confirmation that sensitive data passing through National Instruments R Series devices will be erased when the device loses power. URL: http://digital.ni.com/public.nsf/allkb/03A50BB86120E930862572F40005ED5C
在使用CompactRIO扩展机箱时访问连接器上未用的通道 我在PXI-7831R上使用了一个cRIO-9151扩展机箱。扩展机箱连到了Connector 1上,这是PXI-7831R的DIO连接器。我在查找有关扩展机箱使用了哪些 线的文献。我需要增加能使用的数字通道。有什么方法访问cRIO扩展机箱没有使用的数字线? URL: http://digital.ni.com/public.nsf/allkb/C781C89A34EB832B482572BA001CFBF9
Where Can I Find The Warranty For My NI Hardware? I'm trying to find the warranty information for my NI hardware. Where can I find it? URL: http://digital.ni.com/public.nsf/allkb/8341879DC763DF5886257289005D816E
LabVIEW Real-Time与NI-RIO的兼容性信息 在一个实时控制器中我无法使用LabVIEW 7.1以及NI-RIO 2.X以及更高版本对FPGA编程。提示需要升级LabVIEW。这是什么问题? URL: http://digital.ni.com/public.nsf/allkb/40F269E4A305ADD9482571720005F71B
Compatibility Information of LabVIEW Real-Time with NI-RIO I am not able to use LabVIEW 7.1 and program FPGA’s using NI-RIO 2.X and higher through a real time controller. It requires an upgrade of LabVIEW. What is the problem? URL: http://digital.ni.com/public.nsf/allkb/47C7186E9F7716E98625714F007B571F
Accessing Unused Lines on Connector when Using CompactRIO Expansion Chassis I am using a cRIO-9151 expansion chassis with my PXI-7831R device. The cRIO chassis is connected to Connector 1, which is one of the DIO connectors of the PXI-7831R device. I am looking for documentation on which lines of that DIO connector are mapped and used by the expansion chassis. URL: http://digital.ni.com/public.nsf/allkb/2C12013BB5F090B086256FDD004565A2
Choosing Pull-Up Resistor Values for R Series Devices Digital Output Lines By default, the digital output lines of the R Series devices output a high value of 3.3 V. According to the manual, to create a TTL signal with a 5 V high on the digital output lines, I need to add an external pull-up resistor. What is the output impedance of R Series devices and what value URL: http://digital.ni.com/public.nsf/allkb/D58C269F7771770E86256F490082E6C8
对于PXI/PCI-7831R,我应该如何选择上拉电阻? PXI/PCI-7831R 的数字输出缺省的设置是只能输出3.3V。根据用户手册,为了能输出5V的数字TTL高电平,我需要添加一个外部的上拉电阻。这时候,输出阻抗是多少?这个电阻值应该是多少? URL: http://digital.ni.com/public.nsf/allkb/93A7E429E7D487FB86257027002382A9