What are the pinouts for the cFP-CB-11? I am trying to find the pinouts for the cFP-CB-11. Where can I find this information? URL: http://digital.ni.com/public.nsf/allkb/2DA50514A6ADD94686257465005C0813
Dual Channel RAM Performance for PXI Embedded Controllers What is Dual Channel RAM? What do you need to take full advantage of Dual Channel RAM performance on National Instruments embedded controllers? What are the performance increase when using dual channel RAM? URL: http://digital.ni.com/public.nsf/allkb/52896D53E3136246862573F400808F09
Different Types of Isolation: Channel-to-Channel, Bank (Channel-to-Bus), and Channel-to-Earth Ground Isolation What are the differences between the types of electrical isolation NI offers on devices? I do not understand the differences between channel-to-channel, bank (channel-to-bus), and channel-to-earth ground isolation. URL: http://digital.ni.com/public.nsf/allkb/CF71091043A6193B862573D70077138B
不同种类的隔离:通道与通道隔离,数据层隔离(通道与总线),通道与地隔离 NI 在其设备上提供的几种电气隔离有什么区别呢? 我不太清楚通道与通道隔离,数据层隔离(通道与总线),通道与地隔离这几种隔离方法之间的不同。 URL: http://digital.ni.com/public.nsf/allkb/0189A70B593E669B862574F0003EAD43
FieldPoint OPC Server Update Rate Problem: At what rate does the OPC Server for FieldPoint update? Solution: The update rate is 10 ms, and it cannot be changed. The figure below summarizes how an OPC Server communicates with a FieldPoint Controller. URL: http://digital.ni.com/public.nsf/allkb/8DB8D79FF4AD0E85862573CB00772F6B
Can a cFP-CTR-502 Module Measure a 50KHz Signal? I would like to sample a 50KHz signal with my cFP-CTR-502 module, but the internal frequency references are 1KHz and 32KHz. URL: http://digital.ni.com/public.nsf/allkb/0C61D6B3FE540422862573AA007EB2C9
cFP-CTR-502模块可以测量50KHz信号吗? 我想要用cFP-CTR-502测量一个50KHz的信号,但是内部的参考时钟为1kHz与32Hz.这样可以吗? URL: http://digital.ni.com/public.nsf/allkb/C7A829DAECBF859C862573D70046117E
LabVIEW RT Memory Usage on FieldPoint Controllers I don't know how much memory and storage are left for my applications when I install and run software on my FieldPoint controller. URL: http://digital.ni.com/public.nsf/allkb/EEC34DB19DD2B40A86257377006BD663
How Long does the Internal Real-Time Clock Battery Last in CompactRIO Controller? Usually Real-Time controllers needs CMOS management or a battery for the internal Real-Time Clock. Since cRIO controllers have an internal battery how long does the battery last? URL: http://digital.ni.com/public.nsf/allkb/9976CA1A0092D6AC4825734600574498
Is there a Size Limitation for USB Devices that are Supported on cRIO-901x or cFP-2220 Controllers? I would like to know if there is a size limitation on the supported USB devices for cRIO-901x and cFP-2220 controllers? URL: http://digital.ni.com/public.nsf/allkb/6B33CE34CA6B3BBD4825733F0055E234