Cart
|
Help
NI Home
>
Support
> KnowledgeBase
KnowledgeBase
Select your country
Category(s) Selected
[
start over
]
Question Type
: Specifications/ Documentation [
remove
] ,
Hardware
: Legacy DAQ Devices [
remove
] ,
31-40 of
131
KnowledgeBase [
see results below
]. To refine your results, select another category.
Software
LabVIEW Development Systems
(1)
Driver Software
(7)
Hardware
Analog Output
(3)
Digital I/O
(35)
Multifunction DAQ
(85)
Document Languages
English
(99)
Spanish
(5)
French
(1)
Japanese
(11)
Chinese (Simplified)
(4)
Chinese (Traditional)
(2)
Korean
(9)
Search KnowledgeBase Documents:
Sort by:
Date (Most recent)
Title (A-Z)
31-40 of
131
Previous
|
Next
PXI-6508/PCI-6503のジャンパスイッチ(W1)を使用した起動状態の設定方法
カタログにジャンパ設定により'pull-down'状態に設定できると書いてあるのですが、PCI-6503のマニュアルには参照できるような画像がありません。ジャンパ設定について何か他に参照できるような情報はありますか?
URL:
http://digital.ni.com/public.nsf/allkb/71EBD58481584C4F86256F1A0046F5C6
Setting the PXI-6508 / PCI-6503 Start-Up State Via Jumper W1
I recently purchased a PCI-6503, but the user manual does not have any visual reference to the 'pull-down' jumper mentioned in the catalog. Where can I learn more about the jumpers on this card?
URL:
http://digital.ni.com/public.nsf/allkb/23B042C199D4EF9D86256AB1005E756E
連続、もしくはダブルバッファを使用したデジタル入出力をPCI-6503(8255チップ)で制御することは可能でしょうか?
PCI-6503を使用して連続もしくはダブルバッファでデジタル入出力の制御は可能でしょうか?
URL:
http://digital.ni.com/public.nsf/allkb/69D0DC6C163ED22286256F1A0048A26B
Base Address Conflicts with PC-LPM-16 Legacy Boards
I am encountering base address conflicts when attempting to install a PC-LPM-16. These conflicts seem to arise irregardless of the rocker switch settings and the base address availabilities of my system. Also, the 'Off' label and the arrow that appear on my board seem to indicate conflicting
URL:
http://digital.ni.com/public.nsf/allkb/41AE044186E46D4786256A9D006184A9
LabVIEW を使用したデジタル入力とアナログ入力の同期
PCI-MIO-16E-1 と SC-2040 サンプル&ホールドボードを使って、アナログ 8 チャンネルを集録しています。また、PCI-DIO-96 をアブソリュート・エンコーダと接続して使用しています。これら2つの計測デバイスを同期させることは可能ですか。
URL:
http://digital.ni.com/public.nsf/allkb/CC740655E008C74686256F08007B5B81
Synchronizing Digital Input And Analog Input with LabVIEW
I have an SC-2040 Sample and Hold Board running through a PCI-MIO-16E-1. I am using this to acquire eight analog channel measurements. I also have a PCI-DIO-96 connected to 12-bit absolute encoder. Is it possible to synchronize the measurements taken by these two devices?
URL:
http://digital.ni.com/public.nsf/allkb/4013EDC319EC9CD186256A11000BE62C
What Is the Maximum Front Side Bus Speed That I Can Use with My AT-MIO DAQ Board?
What is the maximum front side bus speed that I can use with my AT-MIO data acquisition (DAQ) board?
URL:
http://digital.ni.com/public.nsf/allkb/B8A26D5C0310BC55862569DC00742195
Which Counter/Timer Chips Are Supported by the ICTR Timing Functions?
Problem: Which counter/timer chips are supported by the ICTR timing functions? Solution: From KnowledgeBase 12EALEH0 (see the Related Link below), each of the boards in the following table uses a counter/timer chip that is best controlled with an ICTR timing function.
URL:
http://digital.ni.com/public.nsf/allkb/3ED5A64CA25DC5DD862569D700716605
National Instrument DAQ 板卡中有那些能与The MathWorks, Inc.'s Data Acquisition Toolbox相兼容?
The MathWorks, Inc.'s 有一个data acquisition toolkit, 它能与NI的一些数据采集板卡协同工作。那么,那些NI的DAQ板卡以及那些版本的驱动能够与这个Toolbox协同工作呢?
URL:
http://digital.ni.com/public.nsf/allkb/E37B636CC6A650BE86256EF200335CCB
Which National Instruments DAQ Devices Are Compatible with The MathWorks, Inc.'s Data Acquisition Toolbox?
The MathWorks, Inc. offers a data acquisition toolkit that can be used with some National Instrument Data Acquisition devices. What National Instruments DAQ devices and what NI-DAQ versions can be used with the toolbox?
URL:
http://digital.ni.com/public.nsf/allkb/1F8D330AA1DDC7448625699F000168D3
Sort by:
Date (Most recent)
Title (A-Z)
31-40 of
131
Previous
|
Next
Search KnowledgeBase Documents: