Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
KnowledgeBase

Category(s) Selected [start over]

Question Type
: Programming [remove] ,
Hardware
: SCXI [remove] ,
21-30 of 113
KnowledgeBase [see results below]. To refine your results, select another category.
Software
LabVIEW Development Systems (8)
Driver Software (20)
Other NI Software (2)
Utility Software (1)
Hardware
Chassis (9)
Modules (67)
Terminal Blocks (19)
Custom Modules and Terminal Blocks (2)
Document Languages
English (66)
Japanese (8)
Chinese (Simplified) (22)
Chinese (Traditional) (5)
Korean (12)

Sort by:
21-30 of 113
|
Accessing Strain Gage Calibration Information Set in MAX I calibrated my strain gage(s) when I created NI-DAQmx Channels in Measurement and Automation Explorer (MAX). How can I retrieve this information to save to file or to display to my user? URL: http://digital.ni.com/public.nsf/allkb/E7588504B22DF07E86256FC60081755F
Is There a LabVIEW Function to Call SCXI_Cal_Constants For Use With the SCXI-1122 Calibration Procedure? My company is a calibration service provider, and I am in the process of calibrating the SCXI-1122 for a customer. However, the official SCXI-1122 Calibration Procedure suggests that I call the SCXI_Cal_Constants function, which is a C function. I would rather use LabVIEW to do this. Is there an URL: http://digital.ni.com/public.nsf/allkb/DA75BB857D20631F86256FC100729378
M系列板卡管脚与SCXI-1349和SCXI-1346旁路接口管脚的对应关系。 M系列板卡的68针管脚与SCXI-1349和SCXI-1346的50针旁路接口管脚是怎样对应的? URL: http://digital.ni.com/public.nsf/allkb/F587FC43CE5980D486256F5000615AA3
Interval Scanning, Simultaneous Sampling, and Round-Robin Scanning Support I am developing an application using some of your data acquisition boards on which I am acquiring from multiple channels. It is very important for me to know exactly how the different channels are getting sampled. Are they scanned one after another or are they sampled at exactly the same time? URL: http://digital.ni.com/public.nsf/allkb/4F9D107D8B26233B86256F250057C9B3
How Do I Measure the Dynamic Resistance of the Strain Gauge? I have a Strain Gauge setup and I would like to measure the dynamic resistance of my Strain Gauge resistor. Is there any way in which I can do that in LabVIEW? URL: http://digital.ni.com/public.nsf/allkb/26A4ECF2B5512C5886257324007F7D6F
How do I Measure the Dynamic Resistance of the Strain Gauge? I have a strain gauge setup and I would like to measure the dynamic resistance of my strain gauge resistor. Is there any way in which I can do that in LabVIEW? URL: http://digital.ni.com/public.nsf/allkb/4BF24ED85F80735286256F1000641232
Checking the SCXI Gain Set by Traditional NI-DAQ in LabVIEW Traditional NI-DAQ automatically sets the optimal gains for my SCXI module based on the input limits I specify. How can I check these gain values? URL: http://digital.ni.com/public.nsf/allkb/C8CDCBFA6E13A7F586256ECF0073C36B
Can I Cascade the Voltage Outputs of an SCXI-1124? I would like to output a voltage higher than 10 V from an SCXI-1124. I know that each channel is isolated and referenced to its GND pin. Can I cascade these outputs to output a larger voltage? URL: http://digital.ni.com/public.nsf/allkb/A88470A95C28D12686256E88006B63BC
SCXI-1124모듈에서 나오는 각각의 신호를 직렬로 더해서 출력할 수 있나요? SCXI-1124를 이용하여 10V 이상의 전압을 출력하고 싶습니다. 각각의 채널이 아이솔레이션 되어 있으며 각각의GND핀에 기준을 삼고 있습니다. 이러한 출력신호들을 직렬연결하여 큰 전압을 출력할 수 있나요? URL: http://digital.ni.com/public.nsf/allkb/21FAD447F993EFA886256FD5003095A9
SCXI-1180의 핀구성은 어떻게 되어 있습니까? 문제점: sCXI-1180 매뉴얼에는 핀구성이 포함되지 있지 않습니다. URL: http://digital.ni.com/public.nsf/allkb/5FF5124BC36A038B86256E9A00047898
Sort by:
21-30 of 113
|