Cart
|
Help
NI Home
>
Support
> KnowledgeBase
KnowledgeBase
Select your country
Category(s) Selected
[
start over
]
Question Type
: Programming [
remove
] ,
Hardware
: SCXI [
remove
] ,
1-10 of
107
KnowledgeBase [
see results below
]. To refine your results, select another category.
Software
Driver Software
(18)
LabVIEW Development Systems
(8)
Other NI Software
(2)
Utility Software
(1)
Hardware
Chassis
(9)
Modules
(63)
Terminal Blocks
(18)
Custom Modules and Terminal Blocks
(2)
Document Languages
English
(62)
Japanese
(8)
Chinese (Simplified)
(20)
Chinese (Traditional)
(5)
Korean
(12)
Search KnowledgeBase Documents:
Sort by:
Date (Most recent)
Title (A-Z)
1-10 of
107
Next
如果使用SCXI-1124输出大于20MA的电流?
我使用一个SCXI-1124以及SCXI-1325接线盒。根据用户手册中的指标,SCXI-1124能够输出的电流介于0到20mA之间。有什么办法让我从这个模块输出大于20mA的电流?
URL:
http://digital.ni.com/public.nsf/allkb/BB6CEE5CBEDECF6248257391000B0F7B
The ; is Being Ignored When I am Externally Triggering a Scan List. on the SCXI-1127
ch0->com0 &&
URL:
http://digital.ni.com/public.nsf/allkb/D1668945410AFAEE8625737900008709
Multichannel SCXI Convert Clock Default Rate Change in NI-DAQmx 8.5
How does NI-DAQmx choose the convert clock rate for a multichannel SCXI acquisition?
URL:
http://digital.ni.com/public.nsf/allkb/1BF39CC271CA7A9D8625728E0061EF95
如何使用NI的产品测量电流?
我想进行电流测量,但是我不知道哪种NI产品可以测量电流并且如何测量?
URL:
http://digital.ni.com/public.nsf/allkb/D84290C812ED19164825726700401FB7
使用SCXI-1520和PXI-4220来测量全桥传感器
我有一个全桥传感器(例如压力传感器、负载单元、扭矩传感器等)。我想对传感器进行激励并且通过SCXI-1520监控响应。我如何使用传统DAQ或者DAQmx 7.x 对SCXI-1520(或PXI-4220)进行配置来创建虚拟通道、任务、或者全局通道来测量我的传感器?
URL:
http://digital.ni.com/public.nsf/allkb/95120F5F3CD30FFB48257249001629CF
我如何在Measurement & Automation Explorer中配置SCXI-1180?
为什么在Measurement & Automation Explorer (MAX)中无法自动检测到SCXI-1180?当我尝试手动“Insert”该模块时,为什么SCXI-1180不在MAX的选项内?
URL:
http://digital.ni.com/public.nsf/allkb/E67C5009CEFD78E24825722D002E35F0
Error 10003 occurs when performing SCXI_SCAN_Config or SCXI_SCAN_Setup.
Why do I get error -10003 when I call SCXI_SCAN_Config or SCXI_SCAN_Setup with a call library function node?
URL:
http://digital.ni.com/public.nsf/allkb/B70F0E818A4F653A862571E6006E43A7
SCXI_SCAN_Config 또는 SCXI_SCAN_Setup을 할때 10003 에러가 발생합니다.
라이브러리 함수 호출 노드로(call library function node) SCXI_SCAN_Config 또는 SCXI_SCAN_Setup을 호출할때 10003 에러가 왜 발생합니까?
URL:
http://digital.ni.com/public.nsf/allkb/8E090735582DC89C86257204002F526D
PXI-4220和SCXI-1520在外部激励的情况下如何使用Offset Nulling?
我使用一个外部电压源向桥式传感器提供激励,在内部激励的时候能够使用Offset Nulling,在外部激励的情况下是否能够使用这个功能?
URL:
http://digital.ni.com/public.nsf/allkb/80F4A94AFC281AC9482571C2002068FF
SCXI-1121上的偏移补偿
当我从SCXI-1121上读数时,在LabVIEW或MAX中读到的数值似乎总是一个比我预料的值高一点或者低一点的常数。对于SCXI-1121来说,不像SCXI-1100不一样,它没有calgnd,那我应该如何补偿这个偏移呢?
URL:
http://digital.ni.com/public.nsf/allkb/7FDBF68A715FD61748257194002EA84E
Sort by:
Date (Most recent)
Title (A-Z)
1-10 of
107
Next
Search KnowledgeBase Documents: