Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
KnowledgeBase

Category(s) Selected [start over]

Question Type
: Programming [remove] ,
Hardware
: Modular Instruments [remove] ,
11-20 of 165
KnowledgeBase [see results below]. To refine your results, select another category.
Software
Calibration Executive (1)
Driver Software (35)
LabVIEW Development Systems (16)
LabVIEW Modules (1)
Measurement Studio (2)
Hardware
Digital Multimeters (DMM) (24)
Digital Transmission Analyzers (1)
Dynamic Signal Acquisition and Analysis (DSA) (74)
High-Speed Digitizers (Scopes) (33)
High-Precision DAQ (Dataloggers) (13)
RF Measurement Devices (12)
Power Supplies (2)
Document Languages
English (81)
Spanish (4)
French (2)
Japanese (10)
Chinese (Simplified) (31)
Chinese (Traditional) (19)
Korean (18)

Sort by:
11-20 of 165
|
Why Do the NI PXI-5600 NI-Tuner VIs Have a Span Input? There are some VIs in the NI-Tuner API that require a span (bandwidth) input, but the NI PXI-5600 downconverter has a fixed 20 MHz real-time bandwidth. URL: http://digital.ni.com/public.nsf/allkb/ACD900CD628D4EFA8625726600089F17
How Can I Maintain an Output Voltage After a Task has Stopped on an NI-4461? When I am outputting a signal on my NI-4461, I notice that the channel resets to zero volts after the DAQmx task is done. I would like it to maintain the last value that was output on the channel. Is this possible? URL: http://digital.ni.com/public.nsf/allkb/DC9D2AB6DFB1924E86257260000CC350
How Do I Know if My PXI Module is Supported in LabVIEW Real-Time? I am trying to use my PXI module in LabVIEW Real-Time and either it is not showing up in Measurement & Automation Explorer (MAX) or I am having difficulties using the module. Is it possible that my PXI module is not supported with LabVIEW Real-Time? Where can I find this information? URL: http://digital.ni.com/public.nsf/allkb/E2DAD2237DA72156862572430081BD49
MI和PXI的Microsoft VB 6.0的工具包 我正在Microsoft VB 6.0下写一个应用程序,将会使用到 NI模块化仪器和PXI产品.对于NI-Sync, NI-TCLK, NI-HWS没有VB 6.0的编程界面,我在VB 6.0里面应该怎样调用这些驱动呢? URL: http://digital.ni.com/public.nsf/allkb/1F53E9759B686F8E48257228002552D6
使用DAQmx同步动态信号采集(DSA)产品 我如何使用DAQmx来实现DSA板卡与其他的DSA板卡或数据采集设备同步? URL: http://digital.ni.com/public.nsf/allkb/84C91151E8EF9CCB4825721F000DD0D0
我能分别触发NI 5102的两个通道吗? 我能分别触发NI 5102的两个通道吗?换句话说,我想用一个触发源去分别触发NI 5102的两个输入通道。 URL: http://digital.ni.com/public.nsf/allkb/E2B07E13624654A94825720A003B9ED1
Microsoft Visual Basic 6.0 Wrappers for NI Sync, NI TClk, and NI HWS I am trying to write an application in Microsoft Visual Basic 6.0 that uses NI modular instruments and PXI products. There is no Visual Basic 6.0 programming interface available for NI-Sync, NI-TClk, and NI-HWS. How can I use these drivers from VB 6.0? URL: http://digital.ni.com/public.nsf/allkb/A48F896EB0F557B5862572050004B567
如何通过Traditional DAQ来使能DSA设备上的IEPE激励 我将NI 4472 DSA设备应用在多个应用中。有时要求在所有的通道上都连接4mA的IEPE加速度计,有时我只是用不需要激励的被动传感器,然而某些情况下我要将不同类型的传感器结合使用。按我所需地在每个通道上使能或者中止4mA激励的最佳方法是什么? URL: http://digital.ni.com/public.nsf/allkb/F19E1521AF9845A648257203002180A6
在同一通道上使用模拟触发条件中的开始触发和参考触发 我使用的数据采集卡是PXI-4461,驱动是NI-DAQmx,我尝试在同一模拟通道上设置两个不同的触发条件:开始触发和参考触发,可是在配置过程中,我不能为不同的触发条件设置各自的触发沿类型,触发沿类型最终与参考触发的触发沿类型相同(最后配置参考触发)。■> URL: http://digital.ni.com/public.nsf/allkb/97EB9A14B2EB41F4482571FE0023E0A5
数字化仪的板上内存 我应该怎么获得我的数字化仪的板载内存的大小信息? URL: http://digital.ni.com/public.nsf/allkb/096BCF7E82309666482571F600031C0C
Sort by:
11-20 of 165
|