Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
KnowledgeBase

Category(s) Selected [start over]

Question Type
: Programming [remove] ,
Hardware
: FieldPoint [remove] ,
1-10 of 99
KnowledgeBase [see results below]. To refine your results, select another category.
Software
Driver Software (17)
LabVIEW Development Systems (14)
LabVIEW Modules (9)
LabWindows/CVI Development Systems (2)
Lookout (1)
Utility Software (5)
Hardware
Controllers/Network Modules (45)
Analog I/O Modules (19)
Discrete I/O Modules (16)
Document Languages
English (60)
Spanish (6)
French (1)
Japanese (9)
Chinese (Simplified) (5)
Chinese (Traditional) (4)
Korean (14)

Sort by:
1-10 of 99
为什么我把我的可执行程序放在我的FIELDPOINT 控制器上后无法读写文件? 当我把我的我的 FieldPoint 控制器作为我的执行目标时,我能够成功地进行文件读写。当我把我的 VI 生成可执行陈绪,把 EXE 放在 FieldPoint 控制器上时(例如,一个启动程序)我无法读写文件。我有什么地方做错了吗? URL: http://digital.ni.com/public.nsf/allkb/5DC40F9D27B918CA4825739200106621
如何增加FieldPoint或者cRIO RTD模块的范围? 我有一个RTD,其电阻值超出了我的RTD模拟输入模块指定的测量范围。可否扩展最大阻值以使我的RTD能够测量? URL: http://digital.ni.com/public.nsf/allkb/3437EF0534231DEC482572BA0012011F
如何使用NI的产品测量电流? 我想进行电流测量,但是我不知道哪种NI产品可以测量电流并且如何测量? URL: http://digital.ni.com/public.nsf/allkb/D84290C812ED19164825726700401FB7
我怎么提高FP-TC-120的测量精度? 在 FP-TC-120的数据手册上,0.2 C 错误被描述为 '当使用FP-TB-3等温底座时,冷端传感器温度和接线端实际温度间的误差', 有没有什么测量方法可以最小化这个误差? URL: http://digital.ni.com/public.nsf/allkb/E08725D6B8FA693E4825725C0033D773
Quel est le rôle du port RS-485 de mon FP-1000? Problème: Quel est le rôle du port RS-485 de mon FP-1000? Solution: Le port RS-485 est un répéteur, vous pouvez seulement y connecter des modules FP-1001. Ce module a été initialement conçu pour être connecté à un port RS-232 d’un ordinateur. URL: http://digital.ni.com/public.nsf/allkb/1C844DFDC578AF52862571F800532772
FieldPoint: 'Remote Panel Connection Exceedes Maximum Number of Licenses' I have LabVIEW 8.0 Professional Development System which gives me a total of 5 remote panel licenses. I am fine using this feature on the host computer; however, when I download the VI to the FieldPoint, I am no longer able to open 5 Internet instances. Instead, I am only able to open up one, and URL: http://digital.ni.com/public.nsf/allkb/03A98313BAA204018625713A006EFC2F
필드포인트(FieldPoint): 'Remote Panel Connection Exceedes Maximum Number of Licenses' 5명의 리무트 패널 라이센스를 가진 LV 8.0 Professional Development System를 사용하고 있으나, FieldPoint에 다운로드 하면 5명의 인터넷 연결을 열수가 없습니다. 대신, 하나를 열고 나서 그다음에 연결하면 'Remote Panel Connection Exceedes Maximum Number of Licenses.' 메세지를 발생합니다 URL: http://digital.ni.com/public.nsf/allkb/14B782328C4CA96A862571D4001D6073
How Do I Adjust the Analog Input Rate of My FieldPoint Modules? Using the Measurement and Automation Explorer (MAX), I do not see how to set the sample rate for my Analog Input module. How can I program the sample rate? URL: http://digital.ni.com/public.nsf/allkb/3DCBB324D23FD637862571320066AA7A
cFP-AI-118のアナログ入力サンプリングレートの設定方法 MAX(Measurement and Automation Explorer )には、cFP-AI-118のアナログ入力サンプリングレートの設定項目がありません。cFP-AI-118のアナログ入力サンプリングレートはどのように設定するのですか? URL: http://digital.ni.com/public.nsf/allkb/3557D65918D2F49386257170000ADBA4
Why is the Scaling I Enabled in MAX Not Working on an Embedded FieldPoint Application? I enabled scaling in Measurement & Automation Explorer under Data Neighborhood»FieldPoint Items»FP@xx_xx_xx_xx»cFP-xx-xxx»Channel 0 with the Scales Tab at the bottom. When I select the cFP Input Module under Data Neighborhood and click on URL: http://digital.ni.com/public.nsf/allkb/5E09B32D9E5BA841862572C3007DB62E
Sort by: