Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
KnowledgeBase

Category(s) Selected [start over]

Question Type
: Programming [remove] ,
Software
: Vision Builder for Automated Inspection [remove] ,
1-10 of 64
KnowledgeBase [see results below]. To refine your results, select another category.
Hardware
Image Acquisition (IMAQ) (3)
Serial (1)
Document Languages
English (21)
Spanish (2)
Japanese (9)
Chinese (Simplified) (9)
Chinese (Traditional) (10)
Korean (13)

Sort by:
1-10 of 64
Using an Encoder to Trigger a IEEE-1394 Camera using Vision Builder for AI and the CVS How do I trigger my IEEE-1394 camera from an encoder through Vision Builder for AI and a Compact Vision System? URL: http://digital.ni.com/public.nsf/allkb/F30085DD93E6396D862573F50005C9A8
How To Correct Calibrated Images in VBAI I'm using Vision Builder for Automated Inspection (VBAI) 3.0.1 to calibrate an image. I would like to perform some processing functions, such as OCR, on the corrected image, but I do not see a function that allows me to correct the calibrated image. I see an option on the Axis tab of the URL: http://digital.ni.com/public.nsf/allkb/3D0F057C457B9210862573250002B330
如何在 VBAI 下修正校正過的影像 我使用 VBAI 3.0.1 校正影像。我想要在我修正過後的影像上使用某些影像處理的函式,例如 OCR,但我在 VBAI 中找不到修正校正影像的函式。我在校正步驟中的 "Axis" 分頁中找到一個選項允許我預覽修正後的影像,但是他卻不允許我在按下 Calibrate Image Setup 視窗 URL: http://digital.ni.com/public.nsf/allkb/E2BDB8001485610686257329000FF818
Returning String Data From VBAI Custom Step I am using the Vision Builder for Automated Inspection (VBAI) Development Toolkit, and I created a custom step in LabVIEW that returns a string value. When I run the step in VBAI, it does not return the correct string value. It either returns no value at all, or it reproduces a previously returned URL: http://digital.ni.com/public.nsf/allkb/AFBAAD8CD6BA68118625727A005397DF
在Vision Builder for AI中设定I/O及转成Labview 我在Vision Builder for Automated Inspection (Vision Builder for AI)中设定Tools底下的Configure Inputs/Outputs,然后我设定信号产生,及数字信号输出,在检测VBAI中很正常,但当我产生Labview程序码,此设定的DIO並没有产生适当的程序码,为什么? URL: http://digital.ni.com/public.nsf/allkb/049F833204146B054825723C00345D0D
Migrating a Vision Builder for Automated Inspection Script to LabVIEW I am planning to migrate my Vision Builder for Automated Inspection (AI) inspection to LabVIEW. Do I need to purchase the Vision Development Module in order to perform this migration? URL: http://digital.ni.com/public.nsf/allkb/F995D8C2F611815E8625721B0082614C
我如何使用Vision Builder AI 1.0产生LabVIEW 7.0程序? 我将LabVIEW升级到LabVIEW 7.0版本。当我使用Vision Builder AI 1.0想要产生LabVIEW程序时,產生的程序无法使用,我该如何解決此问题? URL: http://digital.ni.com/public.nsf/allkb/0A8BCBEFCFC10EF948257217001EC162
为什么我Vision Builder AI或Vision Assistant中的灰度函数是灰色无法使用的? 我在Vision Builder或Vision Assistant中载入一张黑白图像,但却不能用Grayscale菜单中的函数来对它进行操作,请问这是什么原因? URL: http://digital.ni.com/public.nsf/allkb/2D2FBC3BBED058EA48257205002FF92E
Error “VI Path is Invalid” or “LabVIEW X.x VI Required” in Vision Builder for Automated Inspection (AI) I am trying to use the Run LabVIEW VI step in Vision Builder AI. I am able to open a LabVIEW X.x VI, but when I try to run a VI written in a version other than LabVIEW X.x I receive the following error messages: “VI Path is Invalid” or “LabVIEW X.x VI required”. Why URL: http://digital.ni.com/public.nsf/allkb/97B8148EB201782186257202004A879F
我能否在Vision Builder for Automated Inspection(VBAI)2.6中运行LabVIEW 8.0 的VI? 我能否在Vision Builder for Automated Inspection(VBAI)2.6中运行LabVIEW 8.0 的VI? URL: http://digital.ni.com/public.nsf/allkb/E2EB3F54F6FA1241482571F1000D113D
Sort by: