Accelerometer Resonant Frequency Control Missing in DAQmx When setting up an accelerometer channel in Traditional NI-DAQ, I have the option to set the resonant frequency; however, when setting up an accelerometer channel in NI-DAQmx, that option is nowhere to be found. Is that option hidden somewhere, or does it simply not exist? If it doesn't URL: http://digital.ni.com/public.nsf/allkb/BE14EDB0C6B6D54986256F1C0071EB42
Which DIO lines are Reserved for Communication on a TEDS SC-2350 Carrier? When using TEDS class II sensors which DIO lines are available for use and which ones are reserved? URL: http://digital.ni.com/public.nsf/allkb/D3E1C1FBBF2E265F86256F1C006BC405
How Should an SCC-RLY01 Module Be Connected I am using an SCC-RLY01 module, and I need to know how to connect it to my device. URL: http://digital.ni.com/public.nsf/allkb/913EE0DA7B22077C86256F0E005401C0
SCC-RLY01モジュールはどのように接続したらいいのでしょうか? SCC-RLY01モジュールを使っていますが、どのようにデバイスへ接続するのか知りたいです URL: http://digital.ni.com/public.nsf/allkb/3796D86046206E578625700C0047D05A
Offset Nulling with the SCC-SG24 I am using the SCC-SG24 module for strain measurements. When I use the potentiometers to null the offset of my strain gage, the signal remains the same. The offset is still present regardless of how I adjust the nulling potentiometer. What am I doing wrong? URL: http://digital.ni.com/public.nsf/allkb/D58D0C7EA466DC0786256F05006E77DE
Offset Nulling with the SCC-SG24 I am using the SCC-SG24 module for strain measurements. When I use the potentiometers to null the offset of my strain gage, the signal remains the same. The offset is still present regardless of how I adjust the nulling potentiometer. What am I doing wrong? URL: http://digital.ni.com/public.nsf/allkb/9B2FA1CB0CA6384386257168004EE8FE
Setting Up the SCC-ACC01 in a Dual-Stage Configuration I have an SCC-ACC01 (formerly SCC-Integrated Circuit Piezoelectric01) and an SCC-LP0X lowpass filter module. I want to setup the SCC-ACC01 in a dual-stage configuration.When I try to configure the SC-2345 in Measurement & Automation Explorer (MAX) I get an error stating that the URL: http://digital.ni.com/public.nsf/allkb/64FAAD167FB8156A86256D7A006A864C
SCC-ACC01 module이 MAX의 SC-2345 configuration window에서 보이지 않습니다. NI-DAQ 6.9.3과 함께 설치되는 MAX 2.2에서 SC-2345 configuration window안의 Add menu안에 SCC-ACC01 module을 찾을 수 없습니다. URL: http://digital.ni.com/public.nsf/allkb/11C5367B4DD5480F86256EA500043FEF
The SCC-ACC01, Also Called the SCC-ICP01, is Not in the SC-2345 Configuration Window in MAX I cannot find the SCC-ACC01 module in the Add menu of the SC-2345 configuration window in MAX 2.2 with NI-DAQ 6.9.3. URL: http://digital.ni.com/public.nsf/allkb/E238A91B7ACD38CC86256CF70056761C
Is There a Way to Configure All of the SCC Modules Using the Mac OS DAQ Configuration Utility? The Mac OS DAQ Configuration Utility will only allow me to configure specific SCC Modules for my SC-2345. My module does not appear in the list of modules I can add. Is there a way to use SCC modules that are not listed there? URL: http://digital.ni.com/public.nsf/allkb/63AA1575044627B686256BDD007A6B77