Maximum Transfer/Baud Rate with PCMCIA Serial Communication Devices I have a PCMCIA serial communication device that I am trying to configure in Measurement and Automation Explorer (MAX). When I go to the COM port and click on the Port Settings tab, it gives me the option to select my Baud Rate. When I try to set the Baud URL: http://digital.ni.com/public.nsf/allkb/DBDCFCBBCE15ACB286256F15006EE256
PCMCIA 시리얼 통신 장비의 최대 Transfer/Baud Rate. PCMCIA 시리얼 통신 장비를 가지고 있고, 이 장비를 Measurement and Automation Explorer(MAX)에서 설정하려고 합니다. COM포트에 가서 Port Settings 탭에 가서 제가 원하는 Baud Rate를 설정값을 입력합니다. 그런데 제가 최신카탈로그(2004)와 NI-Serial Help에 나와있는 'Max Transfer Rate'을 Ba URL: http://digital.ni.com/public.nsf/allkb/1E0677CAA665C6838625702F000B04B5
Why Don’t My Ports Appear Under VISA Resources in MAX? I have 6 available COM ports on my computer. These ports are displayed in Device Manager in Windows, but I cannot find them in Measurement & Automation Explorer (MAX). Additionally, when I try to use the VISA Find Resource VI in LabVIEW with the "?*" (find all resources) expression, the URL: http://digital.ni.com/public.nsf/allkb/928D3D3B63AF0EF186256F12004D7E12
Error 'Windows is not able to identify or use the inserted PC card device ...' When Using PCMCIA Devices For some undetermined reason, my PCMCIA device stopped working. After some unsuccessful troubleshooting, I rebooted the computer and received an error message stating: 'Windows is not able to identify or use the inserted PC card device because there is no memory area available to URL: http://digital.ni.com/public.nsf/allkb/DD2B8041D7C2B81D86256EFF007C4621
National Instruments Serial Device not Listed in Measurement and Automation Explorer I have installed NI-VISA, but I do not see my National Instruments serial device in Measurement and Automation Explorer (MAX). Am I missing a driver? URL: http://digital.ni.com/public.nsf/allkb/49AF0FB0CADF581F86256EFD007BC43E
NI Instrument Simulator in Serial Mode - Requires NULL Modem Cable I'm connected with a serial cable to my NI Instrument Simulator. Everything is set up correctly (dip switches, powered on, etc.) but I can't read or write to it. I've tried everything but I still can't communicate with my Instrument Simulator. URL: http://digital.ni.com/public.nsf/allkb/FEE80C710D2A0B2E86256EDD0058F3F3
시리얼 모드에서의 NI Instrument Simulator. 널모뎀 케이블 필요 NI Instrument Simulator 과 시리얼 케이블로 연결하고, 모든 설정(딥 스위치, 전원 등)이 제대로 하였습니다. 그러나 읽거나 쓸수가 없습니다. 모든 것들을 해보았으나 여전히 통신이 되지 않습니다. URL: http://digital.ni.com/public.nsf/allkb/6190914C49991BB9862570ED00377D5F
Ports for the PCI-232/2 Do Not Show Up Inside of Device Manager I am using the PCI-232/2 serial hardware with my Windows computer. The serial card gets auto-detected and installed by the operating system, and I can see the listing for the PCI-232/2 but there are no references to the new serial ports under the ports (com & lpt) tree. Why can't I see the URL: http://digital.ni.com/public.nsf/allkb/C17CDB0B2ECFA79686256E9100716387
NI Serial Ports Not Recognized in Windows XP I just installed NI Serial version 1.45 on my Windows XP machine and then installed a new PCMCIA-232 or PCI-232 card. When I go into Device Manager, the ports of the card are not recognized. URL: http://digital.ni.com/public.nsf/allkb/9E7DD5A64F82C6D686256C8D006D3385
Windows XP 無法認出 NI Serial Ports 我剛裝了NI Serial version 1.45 在Windows XP 的電腦上,並且也安裝了PCMCIA-232 或 PCI-232 卡。但我在裝置管理員當中發現卡片上的ports 系統並不認得。 URL: http://digital.ni.com/public.nsf/allkb/11BFDE26BE0C157D86256FEA00079AD7