Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
KnowledgeBase

Category(s) Selected [start over]

Question Type
: Install/Config [remove] ,
Hardware
: FieldPoint [remove] ,
11-20 of 85
KnowledgeBase [see results below]. To refine your results, select another category.
Software
LabVIEW Modules (9)
Driver Software (10)
Other NI Software (2)
Utility Software (9)
Hardware
Controllers/Network Modules (46)
Analog I/O Modules (11)
Discrete I/O Modules (2)
Dual-Channel Modules (6)
Terminal Bases (2)
Document Languages
English (52)
Spanish (5)
Japanese (5)
Chinese (Simplified) (7)
Chinese (Traditional) (2)
Korean (14)

Sort by:
11-20 of 85
|
내 LabVIEW Project에 원하는 FieldPoint 컨트롤러를 추가하지 못하는 이유는 무엇입니까? 나는 FieldPoint 컨트롤러를 타겟으로 하는LabVIEW Real-Time(LVRT)어플리케이션을 빌드하려고 하고 있습니다. 내 컨트롤러와 그와 관련된 모듈이 Measurement & Automation Explorer (MAX)에서는 잘 나타납니다. 이에 앞서 내 FieldPoint 드라이버를 재설치 및 IAK 파일 불러오기를 반복 URL: http://digital.ni.com/public.nsf/allkb/AE7DBE954ED5F9D78625726100382CAA
为什么我的 Fieldpoint 模块上的电源灯一直闪烁? 我的 FP-AIO-600 模块的电源灯一直在开与关的状态闪烁。我不能在模块操作指南中找到这种状态的含义。当我尝试从模块读取数值时,我在所有通道上收到 Bad Channel Status 错误。是否是我的 FP-AIO-600 模块坏了? URL: http://digital.ni.com/public.nsf/allkb/C2D863A81439DD014825721E0022CF7F
為什麼我的 Fieldpoint 模組上的電源燈一直閃爍? 我的 FP-AIO-600 模組的電源燈一直在開與關的狀態閃爍。我不能在模組操作指南中找到這種狀態的含義。當我嘗試從模組讀取數值時,我在所有通道上收到 Bad Channel Status 錯誤。是否是我的 FP-AIO-600 模組壞了? URL: http://digital.ni.com/public.nsf/allkb/106EE91CE8F7E113862572580051068F
Why is the Power Light on My FieldPoint AIO-600 Flashing? The power light on my FP-AIO-600 module is constantly blinking on and off. I can not find anything in the module's operating instructions that indicates what this means. When I try to read values from the module, I just get a Bad Channel Status error on all of URL: http://digital.ni.com/public.nsf/allkb/D62A4A795FACF6F386257215004D6E51
为什么我在连接到远程实时目标的时候会出现LabVIEW实时系统通讯协议版本不匹配的错误? 当我尝试从LabVIEW的项目中连接到远程实时目标或者部署代码时,碰到'Access Denied: LabVIEW RT communication protocol version mismatch'的错误。 URL: http://digital.ni.com/public.nsf/allkb/8F6DAD871CF7CF8F482571FE000C8297
為什麼我在連接到遠程RT目標的時候會出現LabVIEW RT系統通訊協議版本不匹配的錯誤? 當我嘗試從LabVIEW的項目中連接到遠程RT目標或者部署代碼時,碰到'Access Denied: LabVIEW RT communication protocol version mismatch'的錯誤。 URL: http://digital.ni.com/public.nsf/allkb/C04A60697CBA55C98625721800461E05
我如何才能更改一个不在本地子网内的实时控制器(FieldPoint,cRIO等等)的IP地址? 我的FieldPoint,Compact FieldPoint或者Compact RIO控制器和我的上位机不在同一个子网内。如何才能更改这样的控制器的IP地址? URL: http://digital.ni.com/public.nsf/allkb/1275B182F63D77A6482571ED0014C75C
我没有插入我的热电欧模块,为什么我 FP-TC-120 上的 LED 灯没有亮? 我将我的 FP-TC-120 插入我的控制器,并且连上了我的热电欧。但是空的通道的 LED 灯没有亮。为什么? URL: http://digital.ni.com/public.nsf/allkb/A2B4563E0E31338D482571DA001F9419
Why Do I Get a LabVIEW RT Communication Protocol Version Mismatch When Connecting to a Real-Time Target? When I attempt to connect to my Real-Time controller from my LabVIEW project or deploy code, I get the following error: Access Denied: LabVIEW RT communication protocol version mismatch. URL: http://digital.ni.com/public.nsf/allkb/4F11F194B84401B9862571DA00006C6C
왜 Real-Time 타겟과 연결하려고 할때 LabVIEW RT Communication Protocol Version Mismatch라는 에러가 발생합니까? LabVIEW 프로젝트 또는 배포코드로 부터 Real-Time 콘트롤러에 연결을 하려고 하면, 'Access Denied: LabVIEW RT communication protocol version mismatch'라는 에러가 발생합니다. URL: http://digital.ni.com/public.nsf/allkb/14D7364702B3C554862571EA0003EBEE
Sort by:
11-20 of 85
|