Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
KnowledgeBase

Category(s) Selected [start over]

Question Type
: FAQ [remove] ,
Hardware
: SCXI [remove] ,
1-10 of 95
KnowledgeBase [see results below]. To refine your results, select another category.
Software
Driver Software (5)
LabVIEW Development Systems (2)
LabVIEW Signal Express (1)
Utility Software (1)
Hardware
Chassis (13)
Modules (48)
Terminal Blocks (12)
Custom Modules and Terminal Blocks (1)
Document Languages
English (45)
French (2)
Japanese (16)
Chinese (Simplified) (14)
Chinese (Traditional) (4)
Korean (14)

Sort by:
1-10 of 95
Windows Vista DAQPad/DAQCard Support I have a National Instruments DAQPad/Card that worked fine previously, but doesn't function properly in Windows Vista. Why? URL: http://digital.ni.com/public.nsf/allkb/678CCC14FEA8F8CE8625743400680F8D
Maximum Voltage When Using the SCXI-1180/1181 Problem: What is the maximum voltage the SCXI-1180 or SCXI-1181 can handle? Solution: The SCXI-1180/1181 User Manual, p28, has the following warning: Warning: The SCXI-1181 is not intended for use with hazardous voltages (voltages exceeding 42 Vrms). URL: http://digital.ni.com/public.nsf/allkb/5F39B709FC0AE1568625742700453B55
What is the Frequency Response for the SCXI-1102? The manual for the SCXI-1102 lists that the lowpass filter is a two-pole filter with a 2 Hz cutoff frequency to reject 60 Hz noise. What family of filter is this? URL: http://digital.ni.com/public.nsf/allkb/3CFA60E20AC9C72586257341007F3AD4
What is the Frequency Response for the SCXI-1102B? The manual for the SCXI-1102B lists that the lowpass filter in the device is a 3 pole filter with a 200 Hz cutoff frequency. What family of filter is this? URL: http://digital.ni.com/public.nsf/allkb/A21EAC7B480EED958625732C00816637
Can I Use the 9944 and 9945 Bridge Completion Accessories With the SCXI-1314T? I have a 9944 or 9945 bridge completion accessory and would like to use it with my SCXI-1314T TEDS Terminal Block. URL: http://digital.ni.com/public.nsf/allkb/925F415C8BCE5B5F8625729C00736AB8
Which Strain Gauge Modules Support Custom Shunt Calibration Values? National Instruments' strain gauge module 1521x has a Shunt Resistance of 100kΩ, is there anyway of changing this value? URL: http://digital.ni.com/public.nsf/allkb/6B1B3E8A2A484351862572900035F807
哪些美国国家仪器的产品可以被用来作为电流输出? c[FP]-AIO-600 - 8通道,单端参考地,模拟输入/输出混合模块,内部更新率可达1. URL: http://digital.ni.com/public.nsf/allkb/51560496185576ED4825725D002D9E45
M系列板卡的上电状态与SCXI系统 问题: M系列板卡的上电状态会影响SCXI系统吗? 解答: 如果使用NI-DAQmx 7. URL: http://digital.ni.com/public.nsf/allkb/0F2DC0D662E940B68625725C00211DCA
我能否同时用M系列板卡上的两个68针的连接端去连接信号调理模块呢? 我想同时使用M系列板卡上的两个68针的连接端,从而扩大信号调理通道的数目。请问这是否可行? URL: http://digital.ni.com/public.nsf/allkb/5BC2F57FD338E5908625725C0026903F
在一个提供220V电压的国家使用SCXI机箱(美国型号,110V) 我想在一个提供220V电压的国家使用SCXI机箱(美国型号,110V)。可能吗? URL: http://digital.ni.com/public.nsf/allkb/2D869FEDE8CAD87648257249002522F4
Sort by:
1-10 of 95