Cart
|
Help
NI Home
>
Support
> KnowledgeBase
KnowledgeBase
Select your country
Category(s) Selected
[
start over
]
Question Type
: FAQ [
remove
] ,
Hardware
: Digital I/O (DIO) [
remove
] ,
11-20 of
51
KnowledgeBase [
see results below
]. To refine your results, select another category.
Software
Driver Software
(9)
LabVIEW Development Systems
(1)
Other NI Software
(1)
Hardware
High-Speed
(27)
Isolated
(4)
Static
(9)
Document Languages
English
(27)
Spanish
(1)
Japanese
(10)
Chinese (Simplified)
(2)
Chinese (Traditional)
(5)
Korean
(6)
Search KnowledgeBase Documents:
Sort by:
Date (Most recent)
Title (A-Z)
11-20 of
51
Previous
|
Next
Extending your HSDIO Maximum Clock Rate with SerDes
HSDIO의 최대클럭속도보다 더 높은 속도의 serial bitstream 데이터를 읽을 수 있는 방법이 있습니까? 반대로, 더 높은 속도의 serial bitstream을 만들어낼 수 있습니까? Serializers와 Deserializers(SerDes)를 이용하여 구현할 수 있는 방법이 있습니까? NI에서는 어떤 SerDes를 추천■>
URL:
http://digital.ni.com/public.nsf/allkb/788239B07338AFFF862572E600063818
Extending your HSDIO Maximum Clock Rate with SerDes
How can I read a serial bitstream that is faster than the HSDIO maximum clock rate? Likewise, can I generate a serial bitstream at a higher clock rates? How can this be implemented with serializers and deserializers (SerDes), and which products does National Instruments recommend?
URL:
http://digital.ni.com/public.nsf/allkb/8D92A482ED857CD5862572A600719F2E
What Differential Voltages Correspond to High and Low Logic Levels in CAN Protocol?
I would like to acquire my CAN signals through a data acquisition board and to do so I need to know how to interpret the voltages on the differential lines (CAN_H and CAN_L) as logic levels high (dominant) and low (recessive).
URL:
http://digital.ni.com/public.nsf/allkb/F35676D3065CF292862572A400716B77
How do I synchronize multiple 653X devices in DAQmx?
I have multiple 653X devices in my PC and I need to synchronize them with an shared clock.
URL:
http://digital.ni.com/public.nsf/allkb/F2B1273160F9C9E7862572820058537F
Triggering An Acquisition Session of a HSDIO Device
I have configured my HSDIO acquisition session to have a digital start trigger. However, I am receiving a timeout error because it is not seeing the trigger. Why?
URL:
http://digital.ni.com/public.nsf/allkb/CDF43A02E6BB55098625724B00797F88
觸發〈Trigger〉一個 HSDIO 裝置的擷取工作
我為我的 HSDIO 擷取工作設定了數位啟動觸發。然而系統卻沒有收到 trigger 信號而且告訴我 timeout ,為什麼會這樣?
URL:
http://digital.ni.com/public.nsf/allkb/1724E313DA7D144F86257293003FC1DC
Can the PXI-565x be Used as a Clock for the PXI-6562?
I would like to use an external clock for my NI HSDIO PXI-6562. The clock frequency is greater than the PXI-5404 can provide (105 MHz). Since the PXI-565x can generate a sine wave at the required rate, can I use this signal for the clock of my PXI-6562?
URL:
http://digital.ni.com/public.nsf/allkb/E081CCFDC1A1850386257243005A8DDE
Exporting the HSDIO Generation Session Sample Clock
If I configure my HSDIO generation application to export the sample clock, why do I see this sample clock before I initiate the session?
URL:
http://digital.ni.com/public.nsf/allkb/AB13E3DBC0D959A38625723C00757C8D
Handling HSDIO Data Delays Greater Than 100%
NI-HSDIO devices (654x, 655x, 656x) provide a property called Data Position.Delay to account for delays caused by driving data over a transmission line. However, the programmable delay has a maximum range of 100% of a sample clock cycle. How can a delay of greater than 100%
URL:
http://digital.ni.com/public.nsf/allkb/53BFD784329FF5BD86257210005D2004
我能使用SHC68-68-EPM电缆来代替SHC68-C68-D2电缆吗?
当我为654X 或 655X设备配置系统的时候,我需要一根SHC68-C68-D2 68针的电缆,它看起来和价位低一些的SHC68-68-EPM电缆尺寸相同。那么我能使用SHC68-68-EPM电缆来代替SHC68-C68-D2电缆吗?
URL:
http://digital.ni.com/public.nsf/allkb/7DD3C3070D8D6F07482571F600081A23
Sort by:
Date (Most recent)
Title (A-Z)
11-20 of
51
Previous
|
Next
Search KnowledgeBase Documents: