Calibration Executive Report Shows Failure for NI 4060 when Software Indicates Passing When I run a "verify only" on a 4060 it will show as a green PASS but in the report, it does not meet the "as Left" data (which are 24hr specifications) and thus will show FAILED. URL: http://digital.ni.com/public.nsf/allkb/F099D251EAFA73DE862573AE000A6F1C
Only Even Channels Can Calibrate On My 1120/1120D Module When attempting to calibrate an 1120/1120D module in CalExec, I cannot get the odd numbered channels to calibrate. What could be wrong? URL: http://digital.ni.com/public.nsf/allkb/358AA79D3BEAADD6862572BC00752DF5
Can I Use the BNC-2111 for Calibration of a 671x/672x/673x Device? I would like calibrate my 671x/672x/673x device and I have a BNC-2111. The manual states I need a CB-68. URL: http://digital.ni.com/public.nsf/allkb/BD69B93090555F56862572AB0056E7F8
I Cannot Select My GPIB Controlled Counter in CalExec 3.0.1 and Before. When I begin calibration for a certain card, I can select GPIB controlled devices in the initial setup, but not the counter. URL: http://digital.ni.com/public.nsf/allkb/2214541622BBDEF1862572AA006BEDDD
Does Calibration Executive Support USB M-Series Devices? I have a USB M-Series device and I need to calibrate it, can I use Calibration Executive? URL: http://digital.ni.com/public.nsf/allkb/C7D19A19E9B79A4D8625726B00616617
¿Qué Significa el Término “Endian”? He visto los términos “Little Endian” y “Big Endian” usados en la descripción de uno de los programas de ejemplo. ¿A qué se refieren por el término de “Endian”? URL: http://digital.ni.com/public.nsf/allkb/0D9FE6005669BAED8625708C007940BD
Calibrating FieldPoint Modules Using a FieldPoint 2000 with Calibration Executive Can I calibrate my FieldPoint modules using a FieldPoint 2000 (FP-2000) controller and calibration executive? URL: http://digital.ni.com/public.nsf/allkb/C8B6E49ED7A5D8FE86256F26005D6C2E
Calibration Executive 2.2 -- Important Notes Not In Documentation Are there any notes or important information that are not included in the Calibration Executive 2.2 Documentation that I should know of? URL: http://digital.ni.com/public.nsf/allkb/4A741B9536A32D6586256F0B005F4B4B
Why Do I Get an Input Impedance of 750K Ohms When Calibrating a PXI-5112? I am using a Datron/Wavetek 1281 (the 1281 is a 8.5 digit DMM) to measure the input impedance of a PXI-5112 with Calibration Executive. I expect to get an input impedance reading of 1MΩ on all ranges: 40V, 4V, and 0.4V.The problem is when I run the test, I get an input impedance of 1MΩ on URL: http://digital.ni.com/public.nsf/allkb/DC13A3548760A67A86256EE0002DA554
Verify Board Calibration Without Adjusting Calibration Constants Is there a way to verify that my data acquisition device is properly calibrated without adjusting the calibration constants stored in the device's EEPROM? URL: http://digital.ni.com/public.nsf/allkb/C473213FAB6835F186256EDD008268CA