Error -200016 with NI USB-9263
I am running my NI USB-9263 at the maximum rate on all channels with the regeneration mode set to Do Not Allow Regeneration and writing less than 5000 points per write. I receive the error message
URL:
http://digital.ni.com/public.nsf/allkb/7DEB112180E3DA0E862573F3006A6DF7
How do I configure the Input Range of the NI 9237?
The NI 9237 has an input range of 25 mV for every volt of excitation. Since this device can provide a maximum excitation voltage of 10 volts, I expect that a maximum input range of 250 mV. If I configure a task with an input range of more than 25 mV, I get error -200077: "Requested value is
URL:
http://digital.ni.com/public.nsf/allkb/8869E00B851A868E862573D80066A1FB
Warning 200045 When Using NI-9237 in NI cDAQ-9172
When I use my NI-9237 in a NI cDAQ-9172 chassis I receive the following warning:"Warning 200045 occurredPossible Reason(s):Measurements: EEPROM of the device appears to be corrupt. Contact National
URL:
http://digital.ni.com/public.nsf/allkb/26A60C1D0DFF711A8625738500582D03
Channel Names Cause Incorrect Analog Output on NI USB DAQ Devices
When generating a voltage on the analog output of my USB devices (such as the USB-6008/9, cDAQ 9263) I notice that if the channels in my task have a numeric value at the end of the channel name, then I generate incorrect values. Why is this and how can I fix it?
URL:
http://digital.ni.com/public.nsf/allkb/061D00FB903F2F6586257361006C5505
Full Scale Current Output for the NI 9265 on Startup
I have NI-DAQmx 8.6 installed and on startup my NI 9265 in a cDAQ chassis outputs full scale current (20mA). How can I fix this since the power up state of the card should be 0mA as written on the specification.
URL:
http://digital.ni.com/public.nsf/allkb/C86C74450F5B78518625735A0056C8C6
Error -200077 When Using an NI 9263 with Calibration Executive 3.2
When I attempt to calibrate an NI 9263 (cRIO/cDAQ module) with Calibration Executive 3.2, I'm presented with error -200077.
URL:
http://digital.ni.com/public.nsf/allkb/F979EC662795C43C862572B80081D469
当CompactDAQ在笔记本电脑待机模式下的奇怪行为
我使用cDAQ-9172机箱。当我的笔记本电脑从待机模式恢复时,模拟和数字输出的状态改变了。
URL:
http://digital.ni.com/public.nsf/allkb/417D102116DF02A7862572B6002E4C2F
Downgrade Problems With cDAQ and TEDs Bitstreams in NI-DAQmx 8.1 or 8.3
I am using a cDAQ chassis and either downgraded from NI-DAQmx 8.5 or later or am trying to import a Measurement and Automation configuration exported from NI-DAQmx 8.5 or later. However when I do so the configuration seems to be corrupt or will not import successfully. How do I import my
URL:
http://digital.ni.com/public.nsf/allkb/3B1A2F6732895CF786257291005DA7C1
Error -50150 when using cDAQ 9205 with Analog Reference Trigger
I have a cDAQ chassis and would like to use the 9205 to set up an analog reference trigger for the rest of the modules in the chassis. I am able to set up a task in the Measurement and Automation Explorer (MAX) for an analog reference trigger on channel 0 of the 9205. However, once I add
URL:
http://digital.ni.com/public.nsf/allkb/21017DE39A3F17F28625727C0081FA99
Documentation Error in Calibration Procedure for NI 9263
In the Calibration Procedure for the NI 9263 there is a documentation error on page 6 regarding the the input configuration of the DAQmxCreateAOVoltageChan.vi.