Why am I unable to activate my motion hardware?
I attempted to activate my motion control hardware in MAX or in the NI License Manager and was unable to do so, what do I do now?
URL:
http://digital.ni.com/public.nsf/allkb/9386ED50FC5C34288625743200600C43
Error -70207 when Initializing a PCI-7390 Motion Controller
When initializing my PCI-7390, I recive the error -70207 says 'The move cannot be completed because the inhibit input of the commanded axis is active.' Why am I getting this error, and what can I do to initialize the board without getting this error?
URL:
http://digital.ni.com/public.nsf/allkb/E55301855F60C9DA862572C20065ECD4
Why Do I Get Error -70183 When Starting a Move With NI SoftMotion Controller for CANopen?
I can initialize the NI SoftMotion Controller. I can see the position update in 1D Interactive in Measurement and Automation Explorer (MAX). But, when I try to start a move, I get Error -70183 (NIMC - dataTransmissionError). What could be causing this?
URL:
http://digital.ni.com/public.nsf/allkb/E8EA2E1CBA29F06B8625720A00795C28
PXI-8145 Causes Error -70012 on Startup EXEs
I loaded up a startup EXE using Motion on a PXI-8145. I get Error -70012 from my Motion functions during the first ten seconds. After the first ten seconds, I no longer get this error, and the program works fine. Why do I get Error -70012 during the first ten seconds?
URL:
http://digital.ni.com/public.nsf/allkb/DB2525CA0DC5FCDE862571FC0073DA99
System Crash When Using the NI SoftMotion Controller for CANopen with a IEEE 1394 Device
If I have both NI SoftMotion Controller for CANopen and the IEEE 1394 driver installed on a PXI LabVIEW RT target, the system may crash with the following error message: Kernel.446580: Illegal Win32 API called from HW ISR Kernel.146650: Exception before per-thread handler init
URL:
http://digital.ni.com/public.nsf/allkb/3D34792F7F3885B2862571DA0057E8BA
Error -70063 When Using the Configure Buffer or Check Buffer Function
When I try to load a buffer with the Configure Buffer function, I get the following error:Error -70063 occurred at Check BufferPossible reasons:The buffer has not been configured properly. Buffer type cannot be changed. The buffer might exist in ROM, but has not yet been
URL:
http://digital.ni.com/public.nsf/allkb/3FBFAF0216843E508625716300647E71
Read ADC Function on a Motion Controller Causes Error -70022
I have a NI-7350 series Motion Controller board and am developing an application with a servo motor. In part of my program I would like to read the value from my analog transducer and pass that value into my program. When I attempt to use the Read ADC VI in LabVIEW, I get error -70022 saying that
URL:
http://digital.ni.com/public.nsf/allkb/D3CBEE133CAF725186256FA1006DFEB3
在运动控制器中用Read ADC Function导致错误-70022
我有一块NI-7350系列运动控制器板卡,用伺服电机和模拟反馈来开发一个应用。在我的程序中我想要读出模拟传感器的值。当我试图在 LabVIEW中使用Read ADC VI时,我得到了一个错误,错误号为-70022,它说这个操作系统不支持这个命令。这是怎么回事以及如何才能
URL:
http://digital.ni.com/public.nsf/allkb/FF35E82C8BAF37FF8625702C003135F4
Error -70001 When Trying to Initialize Motion Controller
I have an NI Motion Controller board such as a 733x, 734x, or 735x. When I try to initialize the axes, I receive
Error -70001 NIMC_readyToReceiveTimeoutError
. What might be causing this and how can I get rid of it?
URL:
http://digital.ni.com/public.nsf/allkb/222D45248BCA0C0586256F69004A8DC8
初始化運動控制器時發生錯誤代碼-70001
我有一張NI運動控制器,比如說733x,734x或是735x。當我嘗試要初使化運動軸時,卻收到錯誤代碼訊息Error -70001 NIMC_readyToReceiveTimeoutError。是什麼原因造成這個錯誤並且要如何來修正它呢?
URL:
http://digital.ni.com/public.nsf/allkb/60DDBA8C47CD02428625739F001ACC52
Sort by:
Date (Most recent)
Title (A-Z)
1-10 of
16
Next
Search KnowledgeBase Documents: