Error -63001 NI-RIO FPGA Communications Occurs With DMA Transfers From Host to FPGA I am trying to do a DMA transfer from the 900x cRIO RT controller to the cRIO FPGA. The FPGA code compiles. However, when I run the code I get a Real-Time error saying the following: Error -63001: NI-RIO FPGA Communications.Framework: (Hex URL: http://digital.ni.com/public.nsf/allkb/257AF49E2110630F8625741F0062D292
Error -200980 when using DAQmx Event with NI USB-9263 I am using the DAQmx "Every N Samples Transferred from Buffer" event with the NI USB-9263 but receive the following error message when I try to run the code: Error -200980 Possible reason(s): URL: http://digital.ni.com/public.nsf/allkb/250113A02E07E332862574170058A928
Error 50150 - Reboot USB 9162 after upgrading to DAQmx 8.7 Immediately following an upgrade to DAQmx 8.7 and using a USB-9162, a user may see error 50150 when attempting to use the device until they restart Measurement and Automation Explorer (MAX) or reboot. The Found New Hardware Wizard may also prompt you to reboot. USB-9162 devices should not URL: http://digital.ni.com/public.nsf/allkb/D046874B01378D42862574170072561E
Error -200016 con la NI USB-9263 Estoy corriendo mi NI USB-9263 a la máxima frecuencia de muestreo en todos los URL: http://digital.ni.com/public.nsf/allkb/95F76BE0E5A1619D8625747700014B7F
Error -200016 with NI USB-9263 I am running my NI USB-9263 at the maximum rate on all channels with the regeneration mode set to Do Not Allow Regeneration and writing less than 5000 points per write. I receive the error message URL: http://digital.ni.com/public.nsf/allkb/7DEB112180E3DA0E862573F3006A6DF7
在运行FPGA VI时会收到一条“Invalid Bitfile”的错误消息 在试图运行FPGA VI时,收到一条"Invalid Bitfile"的错误消息,而这个VI是刚刚被编译过的。为什么这个位流文件是无效的? URL: http://digital.ni.com/public.nsf/allkb/CE5D1BAFB3CEF3C88625742B0005D766
How do I configure the Input Range of the NI 9237? The NI 9237 has an input range of 25 mV for every volt of excitation. Since this device can provide a maximum excitation voltage of 10 volts, I expect that a maximum input range of 250 mV. If I configure a task with an input range of more than 25 mV, I get Error -200077: URL: http://digital.ni.com/public.nsf/allkb/8869E00B851A868E862573D80066A1FB
Warning 200045 When Using NI-9237 in NI cDAQ-9172 When I use my NI-9237 in a NI cDAQ-9172 chassis I receive the following warning:"Warning 200045 occurredPossible Reason(s):Measurements: EEPROM of the device appears to be corrupt. Contact National URL: http://digital.ni.com/public.nsf/allkb/26A60C1D0DFF711A8625738500582D03
ホストからFPGAにDMA転送する時にエラー-63001が発生します。 cRIOのホスト(RT)側からcRIOのFPGA側へのデータ転送にDMA転送を行おうと考えています。そのため、LabVIEWのプロジェクトエクスプローラのFPGAターゲットでFIFOを作成し、プロパティでTypeの項目をHost to Target - DMAに設定し、FIFOを作成■> URL: http://digital.ni.com/public.nsf/allkb/148D9EDAF7A3BE3E862573850043C395
Channel Names Cause Incorrect Analog Output on NI USB DAQ Devices When generating a voltage on the analog output of my USB devices (such as the USB-6008/9, cDAQ 9263) I notice that if the channels in my task have a numeric value at the end of the channel name, then I generate incorrect values. Why is this and how can I fix it? URL: http://digital.ni.com/public.nsf/allkb/061D00FB903F2F6586257361006C5505