Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
KnowledgeBase

Category(s) Selected [start over]

Question Type
: Bug Fix/ Error Message/ Error Code [remove] ,
Hardware
: Signal Sources (AWG/FG/AO) [remove] ,
11-15 of 15
KnowledgeBase [see results below]. To refine your results, select another category.
Software
Driver Software (1)
Utility Software (1)
Hardware
Arbitrary Waveform and Function Generators (1)
Analog Output Devices (11)
Document Languages
English (10)
Japanese (1)
Chinese (Simplified) (2)
Korean (2)

Sort by:
11-15 of 15
NI-6703/6704で波形を出力しようとするとエラー-10403が発生します。 NI-6703/6704で、固定の電圧を出力する場合はうまく出力できるのですが、波形やスケール配列を出力しようとするとエラー-10403が発生します。これはどうしてでしょうか? URL: http://digital.ni.com/public.nsf/allkb/77BCB374ADBD386A8625702D002F2CA4
Various Errors Using Channels 8 and 9 on the AT-AO-10 Channels 8 and 9 on the AT-AO-10 are handled differently than channels 0 through 7, and this difference can result in the following errors when improperly accessed:In the Measurement & Automation Explorer (MAX) test panel, performing sine wave output on channels 8 or 9 results in the error URL: http://digital.ni.com/public.nsf/allkb/13D559256EEE84408625698C0059551F
Why Do I Get Error 10401 when I Try to Use My NI 5401 Arbitrary Function Generator with Virtual Bench-Arb? I am unable to use my NI 5401 Arbitrary Function Generator in Virtual Bench-Arb. Whenever I try to do so, I get Error 10401 --'The specified device is not a National Instruments product, the driver does not support the device (for example, the driver was released before the device was supported), URL: http://digital.ni.com/public.nsf/allkb/77D1289CCCB535B3862569340052D49A
Error -10010 When Using Odd Buffer Sizes With Certain S Series and Analog Output DAQ Devices My data acquisition (DAQ) device returns error -10010 when I specify an odd number of samples to acquire or updates to generate. Why? URL: http://digital.ni.com/public.nsf/allkb/862567530005F09C8625672E001D9C6F
I am getting an incorrect waveform / computer hang, when I run Waveform Generation in the interrupt mode with no onboard FIFO Waveform Generation using Interrupts and no onboard FIFO does not output a nice, continuous sine wave. The waveform generation is also failing if I use my CD-ROM as a CD-Player at the same time as the Waveform output. This does not happen when I use the AT-MIO E-2, which has a FIFO capability. URL: http://digital.ni.com/public.nsf/allkb/4E00A0B1C1BD5F838625625A0074BCD5
Sort by:
11-15 of 15