Basic (8)
Connector Blocks (9)
E Series (39)
M Series (7)
Portable (27)
Real-Time (4)
S Series (12)
Document Languages
English (97)
Spanish (4)
French (2)
Japanese (17)
Chinese (Simplified) (5)
Chinese (Traditional) (10)
Korean (10)

Sort by:
21-30 of 145
|
장비 리셋후 바로 NI 6143의 Self-Calibration을 수행하도 동작하지 않습니다. National Instruments 로부터 바로 구매한 NI 6143 보드를 가지고 있습니다. 그런데 성능을 확인해보려고 Calibration Executive 를 실행하게 되면 'Verify Only' 단계에서 Fail 이 되어 버립니다. 왜 이런 현상이 발생하는 것입니까? URL: http://digital.ni.com/public.nsf/allkb/6080159BD8D1ABBF862572060003BC06
Why Am I Getting Error -200609 or Error -200802? When attempting to create an analog output task I receive Error -200609 or Error -200802 in DAQmx Write when I write data to the buffer before starting the task. URL: http://digital.ni.com/public.nsf/allkb/34B9B5A331DE0E18862571F80072FAEA
왜 -200609 또는 -200802 에러가 발생합니까? 아날로그 출력 태스크를 만들려고 하려면 태스크가 시작하기 전 버퍼에 데이터를 써주려고 할때 DAQmx Write 에서 -200609 또는 -200802 에러가 발생합니다. URL: http://digital.ni.com/public.nsf/allkb/EB5FFF45F428F16A8625720A000BDFB9
Why Do I Get Error LINK1106 When Attempting To Link nidaqmx.lib in VC++ 5? I am trying to run the example programs located in C:\Program Files\National Instruments\NI-DAQ\Examples\DAQmx ANSI C\ in Visual C++ 5 (Microsoft ™ Visual Studio 97 ™) , but I am getting the following error: Linking… ..\.. \DAQmx ANSI C Dev\lib\msvc\nidaqmx.lib : URL: http://digital.ni.com/public.nsf/allkb/CD258DB1948A1B43862571D40081E8B3
랩뷰 7.1과 CF-6004를 이용한 데이터 수집 시 발생하는 에러 핸들링 랩뷰 7.1을 사용하여 CF-6004를 이용한 데이터 수집 프로그램을 코딩하였습니다. 그런데 PDA에서 실행 시 Memory Chunk Error가 발생합니다. 어떻게 하면 에러없이 프로그램이 작동할 수 있습니까? URL: http://digital.ni.com/public.nsf/allkb/75652C1E3899F597862571C7000DA294
Al hacer una Adquisición Finita a la Máxima Velocidad de todos los Canales de una USB-9201 Aparecen Interferencias Tengo una USB-9201 y estoy ejecutando el ejemplo 'Acq and Graph Voltage - Int Clk ' pulsando el botón de Run continuously o ejecución continua. Noté que después de más o menos 5 minutos de ejecución, aparecía un gran glitch o salto en los datos ( ver pantallazo ). Este efecto sólo aparece en uno de URL: http://digital.ni.com/public.nsf/allkb/1A16D6BB48D0EA488625719B004F5302
USB-9201 glitches when acquiring finite samples at max rate on all channels I have a USB-9201 and I am running the example program 'Acq and Graph Voltage - Int Clk' with the run continuously button. I noticed that after running this VI continuously for about 5 minutes resulted in large glitch in the data (see screenshot). This issue only appears on one of my computers. On URL: http://digital.ni.com/public.nsf/allkb/CC5C83E6571CBA8886257195005645EF
Unusual Counter Behavior with NI USB-DAQPad-6015/16 I have an application that performs buffered counter operations on both counter0 and counter1 of my NI USB-DAQPad-6015/16 device. The readings I get from counter1 are incorrect. If I connect the same signal to both counters and run a buffered edge count example, counter1 returns the same value URL: http://digital.ni.com/public.nsf/allkb/1ECDAC3EC89B43F38625719500679683
Blocage de claviers et de souris durant une génération numérique continue avec un CompactDAQ ou un boitier DAQ USB Blocage de claviers et de souris durant une génération numérique continue avec un CompactDAQ ou un boitier DAQ USB URL: http://digital.ni.com/public.nsf/allkb/245B2DDB162E091F86257194002C767A
Erreur avec le module USB et DAQmx Base sur PDA NI DAQmx Base 2.0.1 supporte l’USB 6008, 6009 et 6501 sur PDA. J’ai occasionnellement des erreurs que je ne sais résoudre. URL: http://digital.ni.com/public.nsf/allkb/24C7BB1915873A258625716C002C461F