Previous
|
Next
Global Positioning System (GPS) Timestamp from the PXI-6608 Shows a 90ms Delay
0. To return the accurate GPS timestamp, subtract 90 ms from the value measured by the PXI-6608.
URL:
http://digital.ni.com/public.nsf/allkb/C916F1749B938B28862571070083A4F1
Error -200077 (0xFFFCF273) During Thermocouple Measurements with SCB-68 or SCXI
Why is using a DAQ device with the SCB-68 or SCXI-1102 for Thermocouple Measurements with Built-In CJC Compensation Yield -200077 Error?
URL:
http://digital.ni.com/public.nsf/allkb/E740DA479107B1468625703B0077037B
Error -200077 (0xFFFCF273) al Realizar Mediciones con Termopares utilizando un SCB-68 o un SCXI
¿Por qué al utilizar un dispositivo DAQ con un SCB-68 o un SCXI-1102 para Mediciones de Termopares con Compensación de Unión Fría (CJC) Interna (Built-In)
URL:
http://digital.ni.com/public.nsf/allkb/B5C1198004968935862573840003C1ED
SCB-68 또는 SCXI로 Thermocouple을 측정하려고하면 -200077(0xFFFCF273)에러가 발생합니다.
SCB-68 또는 SCXI-1102 내부에 있는 CJC 보상회로를 이용하여 DAQ장비로 Thermocouple 측정하려고 하면 왜 -200077(0xFFFCF273)에러가 발생합니까?
URL:
http://digital.ni.com/public.nsf/allkb/97852302224A53EC862571BD000A9C19
The Frequency Output for the 'Measure Frequency (NI-TIO) VI' LabVIEW 6.1 Shipping Example Is Incorrect
I am using the LabVIEW 6.1 shipping example
Measure Frequency (NI-TIO) VI
with my National Instruments NI-TIO counter board. When I run the program, the frequency output is not what is expected. Even if I don't have anything cabled into my card, I always get the same output.
URL:
http://digital.ni.com/public.nsf/allkb/00EAB3989FB59CF986256D830060E2BF
Configuring Multiple Ports for Digital I/O Gives 'badChanError' with PCI-6601
When I try to configure multiple ports on my PCI (or PXI) 6601 board for Digital I/O, I receive the following error in LabWindows/CVI:Function DIG_Prt_Config return value == -10007badChanError: A channel, port, or counter is out of range for the device or configuration;or the
URL:
http://digital.ni.com/public.nsf/allkb/7086265EA2ECF66F862569ED007EF207
Fourth Counter on PCI-6602 Causes DMA Conflict Error Message
I can use three counters correctly in any order, but as soon as I add my fourth counter I get a DMA conflict. What is the problem?
URL:
http://digital.ni.com/public.nsf/allkb/540B236C81310B6F862569B5007D5DDC
PCI-6602 보드의 네번째 카운터의 DMA 충돌 에러 메세지
세개의 카운터를 정상적으로 사용하고 있습니다. 그러나 네번째 카운터를 추가하자 마자 DMA 충돌 에러가 발생합니다. 원인이 무엇입니까?
URL:
http://digital.ni.com/public.nsf/allkb/6B1934DED0BFF38286256D59000DFC76
PCI-6602ボード上の三つのカウンタを使うことが問題無なくできます。しかし、4番目のカウンタを使うと、DMA競合エラーメッセージが出ます。
三つのカウンタをどうな順番でも使うことができますが、4番目のカウンタを加えると「DMA競合」エラーが発生します。なぜですか?
URL:
http://digital.ni.com/public.nsf/allkb/862567530005F0A149256A17000E52DB
Why Do I Get Error 10100 With My Counter/Timer Board?
I am using a counter timer board such as the PCI-6601, PCI-6602, or PXI-6602. When I configure my DIO port for 8 or 16 bits, Port Config.vi returns error 10100. When I configure the port width to be 32 bits, no error is returned. Setting all 32 bits to be used for DIO may not be ideal. Is there a
URL:
http://digital.ni.com/public.nsf/allkb/A768010447AE10758625670C0071F354